scispace - formally typeset
Journal ArticleDOI

Simultaneous measurement of partial discharge and radio-interference voltage

Reads0
Chats0
TLDR
In this paper, a new instrument has been developed which allows simultaneous measurement of partial discharge (PD) and radio interference voltage (RIV) in insulation of high-voltage power apparatus.
Abstract
A new instrument has been developed which allows simultaneous measurement of partial discharge (PD) and radio-interference voltage (RIV) in insulation of high-voltage power apparatus. A distinctive feature of this instrument is that it fulfills the low input impedance (150-Ω) requirement of the RIV measuring standard (NEMA 107) at 1 MHz and, at the same time, presents a high input impedance in the frequency bandwidth used for PD measurement; this high input impedance is required for acceptable measurement sensitivity of PD on power transformers. The instrument has shown stable measuring characteristics during the 16 months that it has been in service at the IREQ HV Laboratory where it is used to test power transformers, reactors, disconnecting switches, capacitors, current and voltage transformers, and other apparatus. The HV Laboratory personnel confirm that the device is practical and easy to handle during tests and saves a considerable amount of time.

read more

Citations
More filters
Journal ArticleDOI

Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System.

TL;DR: An optical fiber Sagnac interferometer system for partial discharge ultrasound detection and optical fiber sensing and time-frequency analysis of the ultrasonic signals excited by the piezoelectric ultrasonic transducer is realized for the first time.
Proceedings ArticleDOI

Radiometric partial discharge detection

TL;DR: In this article, the authors provide an overview of some aspects of radiometric monitoring techniques and outline some research challenges which it is hoped will attract the attention of the many researchers who are continuing to advance the radiometric PD detection, measurement and location technology.
Journal ArticleDOI

Comparison of Three Techniques of Partial Discharge Measurements in Power Transformers

TL;DR: In this article, a comparison of partial discharge (PD) measurements taken on 140 large power transformers using radio-influence voltage (RIV) meters calibrated in pV according to NEMA 107 Standard and also with the aid of wide-band and narrow-band PD detectors calibrated in PC according to IEC Publication 270 is presented in the form of pC/?V ratios and compared to data from the literature.
Journal ArticleDOI

Simplification and cost reduction of visual corona tests

TL;DR: This study detects the visual corona onset by means of a commercial digital camera, which allows locating the critical corona points, thus greatly decreasing the costs of the corona instrumentation, while maintaining the accuracy and sensitivity of the detection method.
Journal ArticleDOI

Partial discharge. IV. Commercial PD testing

TL;DR: In this paper, the authors describe commercially available partial discharge (PD) detectors, along with their important characteristics, including the number of inputs used, the bandwidth of the detector, and the method of display processing.
Related Papers (5)