scispace - formally typeset
Search or ask a question

Showing papers by "Arduino A. Mangoni published in 1995"


Journal ArticleDOI
TL;DR: In congestive heart failure patients, baseline compliance index was significantly less than in normotensive and hypertensive subjects, but the compliance index showed a marked increase after 4 weeks of benazepril administration, and the increase was also marked after 8 weeks of angiotensin-converting enzyme inhibitor treatment.
Abstract: Congestive heart failure is characterized by a clear-cut impairment of arterial compliance of medium-sized arteries, but whether this alteration is irreversible or can be favorably affected by cardiovascular drugs currently used in congestive heart failure treatment is unknown. We studied 9 congestive heart failure patients (New York Heart Association class II; age, [mean +/- SEM] 60.7 +/- 3.3 years) receiving diuretic and digitalis treatment in whom arterial compliance was assessed at the level of the radial artery by an echotracking device capable of measuring the arterial diameter along the entire cardiac cycle. Beat-to-beat arterial blood pressure was concomitantly measured by a Finapres device that allowed diameter-pressure curves and compliance-pressure curves (Langewouters' formula) to be calculated for the entire systolic-diastolic blood pressure range. Arterial compliance was expressed as the area under the compliance-pressure curve normalized for pulse pressure (compliance index). Data were collected before and after 4 and 8 weeks of oral administration of benazepril (10 mg/day). Ten healthy subjects were studied before and after an observational period of 4 weeks (5 subjects) or 8 weeks (5 subjects), and 9 age-matched mildly essential hypertensive subjects studied before and after 4 to 12 weeks of benazepril administration served as control subjects. In congestive heart failure patients, baseline compliance index was significantly less than in normotensive and hypertensive subjects. However, the compliance index showed a marked increase after 4 weeks of benazepril administration (+95.7 +/- 24.9%, P < .05); the increase was also marked after 8 weeks of angiotensin-converting enzyme inhibitor treatment (+77.7 +/- 4.2%, P < .05).(ABSTRACT TRUNCATED AT 250 WORDS)

57 citations


Journal ArticleDOI
TL;DR: In obese and lean subjects baseline radial artery diameter values correlated highly with body weight, body surface area, and body mass index, and both diameter and compliance remained higher in obese than lean subjects after forearm ischemia.
Abstract: Obesity is characterized by a number of cardiovascular alterations, and whether these alterations involve arterial compliance is unknown. In 12 young, obese, normotensive subjects (age, 23.9±1.3 years; mean±SEM) and 12 age- and sex-matched lean control subjects we measured blood pressure, radial artery diameter, and radial artery compliance continuously over the systodiastolic pressure range with a Finapres device and recently developed echo-tracking device. Measurements were obtained at baseline and after prolonged ischemia, that is, when diameter and compliance are increased. Blood pressure values were normal in both groups (obese subjects: 109.2±4.9/68.2±2.7 mm Hg; lean control subjects: 108.2±4.1/60.7±3.8 mm Hg), but in addition to a marked increase in body mass index (38.5±0.8 versus 23.1±0.9 kg/m 2 , P P =NS), increases in left ventricular wall thickness and left ventricular mass index (121.5±4.8 versus 103.4±3.3 kg/m 2 , P P P

56 citations


Journal ArticleDOI
TL;DR: Arterial compliance and arterial compliance modulation are impaired in congestive heart failure, and the impairment is manifest in mild congestiveheart failure as well.
Abstract: Congestive heart failure is accompanied by several hemodynamic alterations. To investigate whether these alterations include reduced arterial compliance, we studied 25 patients (age 57 +/- 2 years, mean +/- SE) with a mild or severe congestive heart failure based on clinical symptoms (New York Heart Association class II vs III or IV) and on echocardiographic alterations of left ventricular diastolic diameter and ejection fraction. Radial artery diameter and blood pressure were continuously measured by Doppler ultrasonography and a finger pressure device, respectively. Compliance was calculated by the Langewouters formula, and compliance values were derived throughout the systolic-diastolic pressure range. The area under the compliance-pressure curve normalized for pulse pressure was used to compare compliance values in the various groups. Data were obtained both in baseline condition and at the release from a 12-minute brachial artery occlusion. Fourteen healthy, age-matched subjects served as controls. Compared with the control group, patients with severe congestive heart failure showed a reduction of baseline compliance index (-48%, p < 0.01). Furthermore, while in control subjects compliance markedly increased after brachial artery occlusion (+43%, p < 0.01), in patients with severe congestive heart failure no increase occurred. No baseline compliance alteration was seen in patients with mild congestive heart failure in whom, however, the postischemic increase in compliance was also significantly blunted (-50% vs controls, p < 0.05). Thus, arterial compliance and arterial compliance modulation are impaired in congestive heart failure. Although more marked in severe congestive heart failure, the impairment is manifest in mild congestive heart failure as well.

48 citations


Journal ArticleDOI
TL;DR: Parental predisposition to hypertension is accompanied by cardiac and arteriolar structural changes qualitatively similar to those found in hypertensive patients, although arteriolars structural changes do not involve all vascular beds.
Abstract: Objective: To evaluate whether a predisposition to hypertension is associated with early cardiac and vascular alterations. Subjects: Twenty-five normotensive subjects with both parents hypertensive (group 1) and 28 age- and sex-matched control subjects with both parents normotensive (group 2). Methods: In the two groups the measurements included: clinic blood pressure; left ventricular end-diastolic diameter, septal wall thickness and posterior wall thickness (by echocardiography); minimal forearm and calf vascular resistances (i.e. resistance assessed immediately after prolonged ischaemia, which depends on arteriolar wall thickness); and baseline and postischaemic radial artery compliance-pressure curves over the systolodiastolic pressure range (by echotracking device and finger blood pressure). Results: Group 1 had a slightly higher clinic blood pressure, and septal and posterior wall thickness, than group 2. Minimal forearm vascular resistance was clearly greater in group 1 than in group 2, whereas minimal calf vascular resistance was not significantly different in the two groups. Radial artery compliance was also similar in the two groups. Conclusions: Parental predisposition to hypertension is accompanied by cardiac and arteriolar structural changes qualitatively similar to those found in hypertensive patients, although arteriolar structural changes do not involve all vascular beds. Arterial compliance is not altered in this condition. Vascular changes may be determined by mechanisms other than blood pressure elevation

35 citations


Journal ArticleDOI
TL;DR: In the anesthetized rat, ultrasound evaluation of the mechanical properties of the common carotid and femoral arteries is a reliable and reproducible technique.
Abstract: Objective : To validate ultrasound assessment of common carotid and femoral artery compliance and distensibility in the anesthetized rat. Materials and methods : A reproducibility study was performed by taking measurements twice on two different days in anesthetized Wistar-Kyoto (WKY) rats. The common carotid or femoral arterial diameter on one side and the contralateral arterial blood pressure were measured using a 10-MHz probe echo-Doppler device and an arterial catheter, respectively. The pressure and diameter data were stored in a computer programmed to calculate the arterial compliance and distensibility coefficients (Reneman formulas) and compliance and distensibility indices (arctangent model of Langewouters). A second experimental session was repeated 1 day later, and mean values, day-to-day mean differences and repeatability coefficients were calculated for each parameter. Results : For both the common carotid and the femoral artery, the mean values for heart rate, mean arterial pressure, arterial diameter, arterial compliance and arterial distensibility were similar on the first and second days ; mean day-to-day differences were small and repeatability coefficients were in the range 5-10% of the mean value for diameter and mean arterial pressure and 10-20% of the mean value for compliance and distensibility. Conclusions : In the anesthetized rat, ultrasound evaluation of the mechanical properties of the common carotid and femoral arteries is a reliable and reproducible technique.

7 citations