scispace - formally typeset
Search or ask a question

Showing papers by "Arlen D. Hanssen published in 2013"


Journal ArticleDOI
TL;DR: These guidelines include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation.
Abstract: These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.

1,716 citations


Journal ArticleDOI
TL;DR: These guidelines include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation.
Abstract: These guidelines are intended for use by infectious disease specialists, orthopedists, and other healthcare professionals who care for patients with prosthetic joint infection (PJI). They include evidence-based and opinion-based recommendations for the diagnosis and management of patients with PJI treated with debridement and retention of the prosthesis, resection arthroplasty with or without subsequent staged reimplantation, 1-stage reimplantation, and amputation.

682 citations


Journal ArticleDOI
TL;DR: PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology.
Abstract: We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.

161 citations


Journal ArticleDOI
TL;DR: The authors' standardized followup of patients undergoing TKA at routine intervals allowed us to discover a higher rate of revision resulting from tibial debonding, and the use of this particular tibIAL tray for primary TKA is discontinued.
Abstract: Background We observed isolated tibial component debonding from the cement in one modern primary TKA design (NexGen LPS 3° tibial tray; Zimmer, Warsaw, IN, USA). This failure mechanism is sparsely reported in the literature.

86 citations


Journal ArticleDOI
TL;DR: It is demonstrated that the use of a standardized clinical pathway reduced hospital LOS, improved clinical outcomes and patient satisfaction while reducing costs for identical surgical procedures.

38 citations


Journal ArticleDOI
TL;DR: Esophago-gastro-duodenoscopy with biopsy was associated with an increased risk of prosthetic joint infection in patients with hip or knee arthroplasties, and this association will need to be confirmed in other epidemiological studies and adequately powered prospective clinical trials prior to recommending antibiotic prophylaxis in these patients.
Abstract: Background There are no prospective data regarding the risk of prosthetic joint infection following routine gastrointestinal endoscopic procedures. We wanted to determine the risk of prosthetic hip or knee infection following gastrointestinal endoscopic procedures in patients with joint arthroplasty. Methods We conducted a prospective, single-center, case-control study at a single, tertiary-care referral center. Cases were defined as adult patients hospitalized for prosthetic joint infection of the hip or knee between December 1, 2001 and May 31, 2006. Controls were adult patients with hip or knee arthroplasties but without a diagnosis of joint infection, hospitalized during the same time period at the same orthopedic hospital. The main outcome measure was the odds ratio (OR) of prosthetic joint infection after gastrointestinal endoscopic procedures performed within 2 years before admission. Results 339 cases and 339 controls were included in the study. Of these, 70 cases (21%) cases and 82 controls (24%)...

32 citations


Journal ArticleDOI
TL;DR: Although CRP and ESR are well established in the diagnosis of infection, no role currently exists for them in predicting the outcomes of irrigation and debridement with insert exchange for the treatment of acute hematogenous total knee arthroplasty infection.
Abstract: The roles of C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) are well established in the diagnosis of total joint infection. However, it is not entirely clear what value preoperative CRP and ESR have in predicting outcomes following irrigation and debridement with insert exchange for acute hematogenous total knee arthroplasty infection. The total joint registry at the authors' institution was reviewed to identify all patients who underwent irrigation and debridement with insert exchange for a diagnosis of acute hematogenous infection of a primary total knee arthroplasty. Patient medical records were then reviewed for preoperative white blood cell count and CRP and ESR levels; interval from symptom onset to surgery; infecting organism; and any additional surgery for infection. Average patient age was 72 years (range, 51-91 years). Forty-four patients were men and 26 were women. Mean follow-up was 54 months (range, 12-176 months). Seventy-two procedures (69 patients) met the inclusion criteria. Of these, 20 (28%) additional procedures for infection were performed and were classified as treatment failures. Average CRP was 173.7 mg/L in the successful group and 159.0 mg/L in the failed group (P=.31). Mean ESR at the time of irrigation and debridement with insert exchange was 61.3 mm/hr in both groups (P=.49). Although CRP and ESR are well established in the diagnosis of infection, no role currently exists for them in predicting the outcomes of irrigation and debridement with insert exchange for the treatment of acute hematogenous total knee arthroplasty infection.

10 citations


Patent
20 Nov 2013
TL;DR: In this article, a prosthetic implant with a stem component is implanted in a cavity in an end of a bone where the hollow sleeve provides an axial channel that extends through the length of the hollow body for receiving the stem component.
Abstract: Methods for supporting a prosthetic implant in a patient are disclosed. In some embodiments, a hollow sleeve and a prosthetic implant with a stem component are implanted in a cavity in an end of a bone where the hollow sleeve provides an axial channel that extends through the length of the hollow sleeve for receiving the stem component. In some embodiments, the hollow sleeve is capable of being impacted into the cavity for obtaining a press fit of the hollow sleeve in the cavity. In some embodiments, the hollow sleeve is formed with a porous material.

5 citations



Patent
17 Jul 2013
TL;DR: In this paper, a tibial augment for use with a knee joint prosthesis, composed of annular members of different stock sizes, each size being configured to fit within a cavity formed in a human tibia, is described.
Abstract: A tibial augment for use with a knee joint prosthesis, composed of annular members of different stock sizes, each size being configured to fit within a cavity formed in a human tibia. The augment may include a stepped distal surface. A provisional (temporary) tibial augment used to ensure a proper fit for the permanent augment is also provided. The provisional may include grooves configured to cooperate with a set of ribs on a tong-like holder used for removing the provisional from the cavity. A pusher for use implanting the tibial augment is also provided. In addition, a system for creating a cavity in a human tibia is also described. The system preferably includes a guide with a slot therein and a set of osteotomes that are inserted within different portions of the slot. Methods for using the tools and/or implanting the prosthetic devices discussed above are also described.