scispace - formally typeset
Search or ask a question

Showing papers by "Barry Blumenfeld published in 1983"


Journal Article•DOI•
TL;DR: In this paper, the spatial resolution and response of the segmented cathode pads of the PEP-4 TPC have been measured with data taken at 8.5 atmospheres of 80% Argon-20% Methane gas with a 4kG magnetic field.
Abstract: The spatial resolution and response of the segmented cathode pads of the PEP-4 TPC have been measured with data taken at 8.5 atmospheres of 80% Argon-20% Methane gas with a 4kG magnetic field. The dependence of the spatial resolution and pad response on drift distance and track-anode crossing angle is presented.

28 citations


Journal Article•DOI•
TL;DR: In this paper, the results obtained with the LBL Time Projection Chamber (TPC) regarding the particle identification by the measurement of the ionization losses in the relativistic rise region were presented.
Abstract: We present here some results obtained with the LBL Time Projection Chamber (TPC) regarding the particle identification by the measurement of the ionization losses in the relativistic rise region. This includes the method of calibration using 55Fe sources, the measurement of the resolution using cosmic rays, which shows an equivalent K-? separation of 4.8 standard deviations at 3.5 GeV/c, and the preliminary results obtained with multihadronic events from e+e- annihilations.

13 citations


Journal Article•
TL;DR: In this article, the LBL Time Projection Chamber is used for particle identification by the measurement of the ionization losses in the relativistic rise region, which shows an equivalent K-pi.. separation of 4.8 standard deviations at 3.5 GeV/c, and preliminary results obtained with multihadronic events from e/sub +/e/sub -/ annihilations.
Abstract: The authors present here some results obtained with the LBL Time Projection Chamber regarding the particle identification by the measurement of the ionization losses in the relativistic rise region. This includes the method of calibration using /sup 55/Fe sources, the measurement of the resolution using cosmic rays, which shows an equivalent K-..pi.. separation of 4.8 standard deviations at 3.5 GeV/c, and the preliminary results obtained with multihadronic events from e/sub +/e/sub -/ annihilations.

13 citations


Journal Article•DOI•
TL;DR: The PEP-4 hexagonal barrel calorimeter, with lead-laminate layers and 5×lOmm2 Geiger-mode discharge cells, has demonstrated excellent stability and uniformity in operation.
Abstract: The PEP-4 hexagonal barrel calorimeter, with lead-laminate layers and 5×lOmm2 Geiger-mode discharge cells, has demonstrated excellent stability and uniformity in operation. The use of projective geometry in half degree-wide cathode strips at ±60 degrees to the sense wire channels provides excellent spatial resolution and reconstruction capability. The electronic noise-to-signal ratio without preamplification is sufficiently low that individual 50 pC Geiger discharges are accurately measured and used for energy calibration. Measurements made at 14.5 GeV e± beam energy have provided preliminary spectra of Bhabhas and of photon-photon invariant mass. The latter show that ?o's can be reconstructed.

8 citations


Journal Article•DOI•
TL;DR: In this article, a Geiger-mode electromagnetic shower calorimeter has been constructed for PEP-4, which consists of six trapezoidal modules covering 75% of 4 π solid angle in a hexagonal array.

7 citations


Journal Article•DOI•
TL;DR: In this paper, two cylindrical drift chambers have been designed and constructed to trigger the Time Projection Chamber and to assist in tracking and momentum reconstruction, with data collected from cosmic rays and actual e+e-collisions during recent experimental runs.
Abstract: A svstem of two cylindrical drift chambers has been designed and constructed to trigger the Time Projection Chamber and to assist in tracking and momentum reconstruction. Performance of these chambers has been studied with data collected from cosmic rays and actual e+e-collisions during recent experimental runs.

7 citations


Journal Article•DOI•
TL;DR: The Time Projection Chamber has operated in the PEP colliding beams at SLAC since January 1982 as mentioned in this paper and has been calibrated and monitored using a computer-controlled test pulser system.
Abstract: The Time Projection Chamber has operated in the PEP colliding beams at SLAC since January 1982. Its signal processing system, containing 16020 channels, has been calibrated and monitored using a computer-controlled test pulser system. We describe the test system and review measurements made with the system of signal processing electronics.

5 citations


Journal Article•DOI•
TL;DR: A.H. Aiharae, M.D. Alston-GarnjostG, D.A. BarbaroGaltieria, A.T. Day', P.J. Derby, R.R. Van Dalen', R.E. Pripstein, and W-M.
Abstract: A large muon detection system has been constructed and is fully operational in the PEP 4 facility. It is more than 99.6% efficient. The system is rugged and reliable. It is possible to verify the integrity of all the chambers in a few minutes. Associated software for identifying muons has been written and is working.

5 citations


Journal Article•
TL;DR: The Time Projection Chamber has operated in the PEP colliding beams at SLAC since January 1982 and has been calibrated and monitored using a computer controlled test pulser system.
Abstract: The Time Projection Chamber has operated in the PEP colliding beams at SLAC since January 1982. Its signal processing system, containing 16020 channels, has been calibrated and monitored using a computer controlled test pulser system. The authors describe the test system and review measurements made with the system of signal processing electronics.

4 citations