scispace - formally typeset
Search or ask a question

Showing papers by "Jennifer A. Smith published in 2010"


Journal ArticleDOI
TL;DR: The pre-print version of the Published Article can be accessed from the link below - Copyright @ 2010 Springer Verlag as discussed by the authors, which can be viewed as a preprint of the published article.
Abstract: This is the pre-print version of the Published Article, which can be accessed from the link below - Copyright @ 2010 Springer Verlag

717 citations


Journal ArticleDOI
TL;DR: In this article, the authors measured the transverse momentum and pseudorapidity distributions in proton-proton collisions at root s = 7 TeV with the inner tracking system of the CMS detector at the LHC.
Abstract: Charged-hadron transverse-momentum and pseudorapidity distributions in proton-proton collisions at root s = 7 TeV are measured with the inner tracking system of the CMS detector at the LHC. The charged-hadron yield is obtained by counting the number of reconstructed hits, hit pairs, and fully reconstructed charged-particle tracks. The combination of the three methods gives a charged-particle multiplicity per unit of pseudorapidity dN(ch)/d eta vertical bar(vertical bar eta vertical bar<0.5) = 5.78 +/- 0.01(stat) +/- 0.23(stat) for non-single-diffractive events, higher than predicted by commonly used models. The relative increase in charged-particle multiplicity from root s = 0.9 to 7 TeV is [66.1 +/- 1.0(stat) +/- 4.2(syst)]%. The mean transverse momentum is measured to be 0.545 +/- 0.005(stat) +/- 0.015(syst) GeV/c. The results are compared with similar measurements at lower energies.

464 citations


Journal ArticleDOI
TL;DR: In this article, the trajectories of charged particles produced in the collisions were reconstructed using the all-silicon Tracker and their momenta were measured in the 3.8 T axial magnetic field.
Abstract: The first LHC pp collisions at centre-of-mass energies of 0.9 and 2.36 TeV were recorded by the CMS detector in December 2009. The trajectories of charged particles produced in the collisions were reconstructed using the all-silicon Tracker and their momenta were measured in the 3.8 T axial magnetic field. Results from the Tracker commissioning are presented including studies of timing, efficiency, signal-to-noise, resolution, and ionization energy. Reconstructed tracks are used to benchmark the performance in terms of track and vertex resolutions, reconstruction of decays, estimation of ionization energy loss, as well as identification of photon conversions, nuclear interactions, and heavy-flavour decays.

194 citations


Journal ArticleDOI
TL;DR: In this article, the performance of high-level trigger, identification, and reconstruction algorithms for a broad range of muon momenta was evaluated using a large data sample of cosmic-ray muons recorded in 2008.
Abstract: The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10 GeV/c to about 1% at 500 GeV/c.

115 citations


Journal ArticleDOI
TL;DR: In this article, the operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described and the stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of light monitoring system is presented.
Abstract: The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.

100 citations


Journal ArticleDOI
TL;DR: In this paper, noise rejection algorithms are applied to LHC collision data at the trigger level or in the offline analysis to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the physics trigger operation.
Abstract: Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation.

88 citations


Journal ArticleDOI
TL;DR: In this paper, the Pre-print version of the article can be accessed from the link below - Copyright @ 2010 IOP, and the official published version can be found in the link above.
Abstract: This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOP

86 citations


Journal ArticleDOI
TL;DR: The size of the correlated particle emission region is seen to increase significantly with the particle multiplicity of the event, and the signal is observed in the form of an enhancement of pairs of same-sign charged particles with small relative four-momentum.
Abstract: Bose-Einstein correlations have been measured using samples of proton-proton collisions at 0.9 and 2.36 TeV center-of-mass energies, recorded by the CMS experiment at the CERN Large Hadron Collider. The signal is observed in the form of an enhancement of pairs of same-sign charged particles with small relative four-momentum. The size of the correlated particle emission region is seen to increase significantly with the particle multiplicity of the event.

67 citations


Journal ArticleDOI
TL;DR: The Cosmic Run At Four Tesla (CMS) data-taking exercise was conducted by the CMS Collaboration in late 2008 to complete the commissioning of the experiment for extended operation.
Abstract: The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities.

67 citations


Journal ArticleDOI
TL;DR: In this article, a measurement of the underlying activity in scattering processes with transverse momentum scale in the GeV region is performed in proton-proton collisions at 0.9 TeV, using data collected by the CMS experiment at the LHC.
Abstract: A measurement of the underlying activity in scattering processes with transverse momentum scale in the GeV region is performed in proton-proton collisions at sqrt(s) = 0.9 TeV, using data collected by the CMS experiment at the LHC. Charged hadron production is studied with reference to the direction of a leading object, either a charged particle or a set of charged particles forming a jet. Predictions of several QCD-inspired models as implemented in PYTHIA are compared, after full detector simulation, to the data. The models generally predict too little production of charged hadrons with pseudorapidity eta 0.5 GeV/c, and azimuthal direction transverse to that of the leading object.

65 citations


Journal ArticleDOI
TL;DR: In this paper, the Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise.
Abstract: The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected.

Journal ArticleDOI
TL;DR: In this paper, a detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers.
Abstract: The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location.

Journal ArticleDOI
TL;DR: The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned as mentioned in this paper, and the energy response of the HCAL determined from test beam data has been checked.
Abstract: The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked.

Journal ArticleDOI
TL;DR: Although a high correlation was observed in the DNAm profile between PBC and TBL, there was variation across samples from different DNA resources and donors, and the two sources of the DNA samples could be accurately predicted.
Abstract: Epidemiological studies of DNA methylation (DNAm) profiles may hold substantial promise for identifying mechanisms through which genetic and environmental factors jointly contribute to disease risk. Different cell types are likely to have different DNAm patterns. We investigate the DNAm differences between two types of biospecimens available in many genetic epidemiology studies. We compared DNAm patterns in two different DNA samples from each of 34 participants in the Genetic Epidemiology Network of Arteriopathy study (20 Caucasians and 14 African-Americans). One was extracted from peripheral blood cells (PBC) and the other from transformed B-lymphocytes (TBL). The genome-wide DNAm profiles were compared at over 27,000 genome-wide methylation sites. We found that 26 out of the 34 participants had correlation coefficients higher than 0.9 between methylation profiles of PBC and TBL. Although a high correlation was observed in the DNAm profile between PBC and TBL, we also observed variation across samples from different DNA resources and donors. Using principal component analysis of the DNAm profiles, the two sources of the DNA samples could be accurately predicted. We also identified 3,723 autosomal DNAm sites that had significantly different methylation statuses in PBC compared to TBL (Bonferroni corrected p value <0.05). Both PBC and TBL provide a rich resource for understanding the DNAm profiles in humans participating in epidemiologic studies. While the majority of DNAm findings in PBC and TBL may be consistent, caution must be used when interpreting results because of the possibility of cell type-specific methylation modification.

Journal ArticleDOI
TL;DR: The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap as discussed by the authors, which was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking.
Abstract: The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.

Journal ArticleDOI
TL;DR: In this article, the resolution and linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons.
Abstract: The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008.

Journal ArticleDOI
TL;DR: In this article, a search for quark compositeness in the form of quark contact interactions, based on hadronic jet pairs (dijets) produced in proton-proton collisions at sqrt(s) = 7 TeV, is described.
Abstract: A search for quark compositeness in the form of quark contact interactions, based on hadronic jet pairs (dijets) produced in proton-proton collisions at sqrt(s)=7 TeV, is described. The data sample of the study corresponds to an integrated luminosity of 2.9 inverse picobarns collected with the CMS detector at the LHC. The dijet centrality ratio, which quantifies the angular distribution of the dijets, is measured as a function of the invariant mass of the dijet system and is found to agree with the predictions of the Standard Model. A statistical analysis of the data provides a lower limit on the energy scale of quark contact interactions. The sensitivity of the analysis is such that the expected limit is 2.9 TeV; because the observed value of the centrality ratio at high invariant mass is below the expectation, the observed limit is 4.0 TeV at the 95% confidence level.

Journal ArticleDOI
TL;DR: In this paper, the performance of the Silicon Strip Tracker with cosmic ray muons has been investigated in the presence of the 3.8 T magnetic field produced by the superconducting solenoid.
Abstract: During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.

Journal ArticleDOI
TL;DR: In this article, the authors used cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests to align the CMS muon system.
Abstract: The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.

Journal ArticleDOI
TL;DR: Verbal autopsy can consistently measure AIDS mortality with a set of nine criteria and addition of a handful of questions related to opportunistic infections would enable other widely used verbal autopsy tools to apply this validated method in areas for which HIV testing and hospital records are unavailable or incomplete.
Abstract: Background Verbal autopsy is currently the only option for obtaining cause of death information in most populations with a widespread HIV/AIDS epidemic. Methods With the use of a data-driven algorithm, a set of criteria for classifying AIDS mortality was trained. Data from two longitudinal community studies in Tanzania and Zimbabwe were used, both of which have collected information on the HIV status of the population over a prolonged period and maintained a demographic surveillance system that collects information on cause of death through verbal autopsy. The algorithm was then tested in different times (two phases of the Zimbabwe study) and different places (Tanzania and Zimbabwe). Results The trained algorithm, including nine signs and symptoms, performed consistently based on sensitivity and specificity on verbal autopsy data for deaths in 15e44-year-olds from Zimbabwe phase I (sensitivity 79%; specificity 79%), phase II (sensitivity 83%; specificity 75%) and Tanzania (sensitivity 75%; specificity 74%) studies. The sensitivity dropped markedly for classifying deaths in 45e59-year-olds. Conclusions Verbal autopsy can consistently measure AIDS mortality with a set of nine criteria. Surveillance should focus on deaths that occur in the 15e44-year age group for which the method performs reliably. Addition of a handful of questions related to opportunistic infections would enable other widely used verbal autopsy tools to apply this validated method in areas for which HIV testing and hospital records are unavailable or incomplete.

Journal ArticleDOI
TL;DR: In this paper, the performance of the detector during these dedicated runs is reported, with a typical detection efficiency of 90% of channels being operational with typical efficiency of 98% of the channels being available.
Abstract: In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.

Journal ArticleDOI
TL;DR: In this article, the performance of the drift tube barrel muon detector at the Four Tesla Cosmonautic Run at Four Tesla (CMS-4 Tesla) was investigated.
Abstract: Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 microns, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector.

Journal ArticleDOI
TL;DR: In this article, a large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate of the electromagnetic calorimeter.
Abstract: A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in lead tungstate is measured to be 160+5/-6 plus or minus 8 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy.

Journal ArticleDOI
TL;DR: In this article, a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC, is presented.

Journal ArticleDOI
TL;DR: In this paper, a preprint version of the article can be accessed from the link below - Copyright 2010 IOP and the official published version can be found in the link above.
Abstract: This is the Pre-print version of the Article. The official published version of the paper can be accessed from the link below - Copyright 2010 IOP

Journal ArticleDOI
TL;DR: In this paper, the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter are discussed and compared from test beam data taken in the years 2004 and 2006.
Abstract: This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns.

Journal ArticleDOI
TL;DR: The Cosmic Run At Four Tesla (CMS) data taking exercise was held in 2008 as discussed by the authors, with the goal of commissioning the experiment for extended operation, with all installed detector systems participating.
Abstract: The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data.

Journal ArticleDOI
TL;DR: This well-sampled cohort with acute HCV infection was characterized by dynamic coinfection with multiple viral subtypes, representing a highly complex virologic landscape extremely early in infection.
Abstract: Introduction. Acute hepatitis C virus (HCV) infection is rarely studied, but virus sequence evolution and hostvirus dynamics during this early stage may influence the outcome of infection. Hypervariable region 1 (HVR1) is genetically diverse and under selective pressure from the host immune response. We analyzed HVR1 evolution by frequent sampling of an acutely infected HCV cohort. Methods. Three or more pretreatment samples were obtained from each of 10 acutely infected subjects. Polymerase chain reaction amplification was performed with multiple primer combinations to identify the full range of sequences present. Positive samples were cloned and sequenced. Phylogenetic analyses were used to assess viral diversity. Results. Eight of the 10 subjects were coinfected with at least 2 HCV subtypes. Multiple subtypes were detected in individual samples, and their relative proportions changed through acute infection. The subjects with the most complex subtype structure also had a dynamic viral load; however, changes in viral load were not directly linked to changes in subtype. Conclusions. This well-sampled cohort with acute HCV infection was characterized by dynamic coinfection with multiple viral subtypes, representing a highly complex virologic landscape extremely early in infection.

Journal ArticleDOI
TL;DR: In this paper, the performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008.
Abstract: The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams.

Journal ArticleDOI
TL;DR: In this article, the Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps and their performance has been evaluated using data taken during a cosmic ray run in fall 2008.
Abstract: The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 mu m to 243 mu m. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns.