J
John W. Lehmann
Researcher at Mayo Clinic
Publications - 14
Citations - 2037
John W. Lehmann is an academic researcher from Mayo Clinic. The author has contributed to research in topics: Catheter ablation & Internal medicine. The author has an hindex of 10, co-authored 12 publications receiving 1901 citations. Previous affiliations of John W. Lehmann include Montreal Heart Institute.
Papers
More filters
Journal ArticleDOI
Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial.
Douglas L. Packer,Robert C. Kowal,Kevin R. Wheelan,James M. Irwin,Jean Champagne,Peter G. Guerra,Marc Dubuc,Vivek Y. Reddy,Linda Nelson,Richard G. Holcomb,John W. Lehmann,Jeremy N. Ruskin,Stop Af Cryoablation Investigators +12 more
TL;DR: The STOP AF trial demonstrated that cryoballoon ablation is a safe and effective alternative to antiarrhythmic medication for the treatment of patients with symptomatic paroxysmal AF, for whom at least one antiarrHythmic drug has failed, with risks within accepted standards for ablation therapy.
Journal ArticleDOI
Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation.
Paul Khairy,Patrick Chauvet,John W. Lehmann,Jean Lambert,Laurent Macle,Jean-François Tanguay,Martin G. Sirois,Domenic Santoianni,Marc Dubuc +8 more
TL;DR: RF energy is significantly more thrombogenic than cryoenergy, with a higher incidence of thrombus formation and largerThrombus volumes, likely reflecting intact tissue ultrastructure with endothelial cell preservation.
Patent
Endovascular cryotreatment catheter
Miriam Lane,Leonilda Capuano,David Holtan,Jean-Pierre Lalonde,Claudia Lückge,Jean-Luc Pageard,Marwan Abboud,Johnny Al Asmar,Abderrahim Benrabah,Ken Chen,John W. Lehmann,Philippe Marchand,Robert Martin,Fredric L. Milder,Daniel Nahon +14 more
TL;DR: In this paper, an elongated catheter with a distal balloon assembly is adapted for endovascular insertion, where a secondary outer balloon surrounds a primary inner balloon, the primary balloon being filled with coolant and acting as the cooling chamber, the secondary balloon being coupled to a vacuum return lumen to serve as a robust leak containment device and thermal insulator around the balloon.
Journal ArticleDOI
The REDUCE pivotal trial: a prospective, randomized controlled pivotal trial of a dual intragastric balloon for the treatment of obesity
Jaime Ponce,George Woodman,James M. Swain,Erik B. Wilson,Wayne J. English,Sayeed Ikramuddin,Eric S. Bour,Steven A. Edmundowicz,Brad Snyder,Flavia Soto,Shelby Sullivan,Richard G. Holcomb,John W. Lehmann +12 more
TL;DR: The DBS was significantly more effective than diet and exercise in causing weight loss with a low adverse event profile and accommodation symptoms abated rapidly with support and medication.
Journal ArticleDOI
Incidence and Significance of Early Recurrences of Atrial Fibrillation After Cryoballoon Ablation Insights From the Multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial
Jason G. Andrade,Paul Khairy,Laurent Macle,Doug L. Packer,John W. Lehmann,Richard G. Holcomb,Jeremy N. Ruskin,Marc Dubuc +7 more
TL;DR: ERAF after cryoballoon ablation occurs in ≈50% of patients and is strongly associated with LR, and early reablation for ERAF is associated with excellent long-term freedom from recurrent AF.