Journal ArticleDOI
TL;DR: In this article, the authors proposed a turbine inlet air cooling system that utilizes the cooling tower as primary source of cooling simultaneously with the chiller which serves as a secondary source at elevated wet bulb temperature.
Abstract: Free-cooling is a well-known concept in the HVAC industry in which the cold water produced by cooling tower is used directly to satisfy the requirement of the cooling load without assistance by the chiller, this concept, however, is not reported in the turbine inlet air cooling applications. Free-cooling works well as long as the ambient wet bulb temperature WBT is sufficiently low to produce cold water at the required temperature but once WBT reaches its threshold value hence free-cooling mode is ceased and the chiller kicks off working under its normal mode of operation i.e. free-cooling is either enabled or disabled. The proposed system in this paper provides in addition to the above modes of operation a novel mode that utilizes the cooling tower as primary source of cooling simultaneously with the chiller which serves as a secondary source at elevated WBT. This new feature significantly reduces the yearly operating hours of the chiller and possibly its size depending on the desired inlet air temperature, actual weather conditions and design WBT. Chiller size can vary between 0-100 percent as compared to a similar classical chiller system with significant reduction in the operating hours. The proposed system basically consists of chiller, cooling tower, cooling coils, interconnecting piping and controls. The arrangement of the system equipments changes with the operation modes in two configurations; dual water circulation loops and single water circulation loop. In the dual loops configurations the system has two separate loops such that the evaporator and the cooling coils are tied in one loop while the cooling tower and condenser in the other loop whereas in the single loop configuration all equipments are connected in series in one water circulation loop. This paper presents the major equipments and characteristics of the novel chiller scheme. In addition, the study outlines the potential reduction in the chiller load, size and operating hours under a generalized weather envelope. The paper in general portrays the feasibility of using the proposed cooling scheme for turbine inlet air cooling.Copyright © 2007 by ASME

5 citations


Network Information
Related Institutions (5)
Anadarko Petroleum
513 papers, 10.3K citations

82% related

Geoservices
484 papers, 7.9K citations

79% related

Western Atlas
844 papers, 15.5K citations

78% related

Total S.A.
2.4K papers, 69.5K citations

78% related

CGG
2K papers, 20.2K citations

78% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20172
20155
201410
20138
201212
20113