scispace - formally typeset
Search or ask a question

Showing papers in "Analytical chemistry insights in 2008"


Journal ArticleDOI
TL;DR: FTIR technique proves to be an efficient tool for detecting structural changes and probable binding sites induced by the presence of a metal pollutant, cadmium, in the marine environment.
Abstract: The aim of this study is to adopt the approach of metabolic fi ngerprinting through the use of Fourier Transform Infrared (FTIR) technique to understand changes in the chemical structure in Padina tetrastromatica (Hauck). The marine brown alga under study was grown in two different environmental conditions; in natural seawater (P. tetrastromatica (c)) and in seawater suplemented with 50 ppm of cadmium (P. tetrastromatica (t)) for a three-week period in the laboratory. The second derivative, IR specrum in the mid-infrared region (4000-400 cm −1 ) was used for discriminating and identifying various functional groups present in P. tetrastromatica (c). On exposure to Cd, P. tetrastromatica (t) accumulated 412 ppm of Cd and showed perturbation in the band structure in the mid-IR absorption region. Variation in spectral features of the IR bands of P. tetrastromatica (untreated and treated) suggests that cadmium ions bind to hydroxyl, amino, carbonyl and phosphoryl functionalities. This was attributable to the presence of the following specifi c bands. A band at 3666 cm −1 in untreated P. tetrastromatica (c) while a band at 3560 cm −1 in Cd-treated P. tetrastromatica (t) due to non bonded and bonded O-H respectively. Similarly, non bonded N-H for P. tetrastromatica (c) showed two bands at 3500 cm −1 and 3450 cm −1 due to the N-H stretching vibrations and a band at 1577cm −1 due to N-H bending vibrations, while an intense band at 3350 cm −1 due to bonded N-H stretching vibrations and at 1571 cm −1 due to bending vibrations was observed for Cd-treated P. tetrastromatica (t). Involvement of ester carbonyl group is characterized by the presence of a band at 1764 cm −1 in untreated P. tetrastromatica (c) while the Cd-treated P. tetrastromatica (t) showed the band at 1760 cm −1 . The intensity of the band at 1710 cm −1 in the control samples decreased drastically after cadmium treatment indicating carbonyl of COOH to be involved in metal chelation. A band at 1224 cm −1 for untreated P. tetrastromatica (c) and at 1220 cm −1 for Cd-treated P. tetrastromatica (t) is indicative of the involvement of phosphoryl group in metal binding. Several other such changes were also evident and discussed in this paper. Based on our observation, FTIR technique proves to be an effi cient tool for detecting structural changes and probable binding sites induced by the presence of a metal pollutant, cadmium, in the marine environment.

145 citations


Journal ArticleDOI
TL;DR: A literature platform of the structural elucidations so far investigated has been presented with detailed descriptions as applicable to microbial lipases, and a case study of Candida rugosa lipase has been discussed which highlights important structural features also common to most lipases.
Abstract: The structural elucidations of microbial lipases have been of prime interest since the 1980s. Knowledge of structural features plays an important role in designing and engineering lipases for speci...

44 citations


Journal ArticleDOI
TL;DR: GC-EI/SIM was more prone to interference issues than NCI methods, but gave good sensitivity for pesticides with poor NCI response, while GC-NCI/SRM is recommended for use where added selectivity or confirmation is required.
Abstract: A comparison of detection limits of gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) with gas chromatography-tandem mass spectrometry (GC-MS/MS) in selected reaction monitoring (SRM) mode with both electron ionization (EI) and negative-ion chemical ionization (NCI) are presented for over 50 pesticides ranging from organochlorines (OCs), organophosphorus pesticides (OPs) and pre-emergent herbicides used in the Canadian prairies (triallate, trifluralin, ethalfluralin). The developed GC-EI/SIM, GC-NCI/SIM, and GC-NCI/SRM are suitable for the determination of pesticides in air sample extracts at concentrations <100 pg µL−1 (<100 pg m−3 in air). No one method could be used to analyze the range of pre-emergent herbicides, OPs, and OCs investigated. In general GC-NCI/SIM provided the lowest method detection limits (MDLs commonly 2.5–10 pg µL−1) along with best confirmation (<25% RSD of ion ratio), while GC-NCI/SRM is recommended for use where added selectivity or confirmation is required (such as parathion-ethyl, tokuthion, carbofenothion). GC-EI/SRM at concentration <100 pg µL−1 was not suitable for most pesticides. GC-EI/SIM was more prone to interference issues than NCI methods, but gave good sensitivity (MDLs 1–10 pg µL−1) for pesticides with poor NCI response (OPs: sulfotep, phorate, aspon, ethion, and OCs: alachlor, aldrin, perthane, and DDE, DDD, DDT).

28 citations


Journal ArticleDOI
TL;DR: Stability of Palm-Based Standard Reference Materials remained stable at temperatures of 0 °C, 6 °C and 24 °C upon storage for one year and repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%.
Abstract: This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of –20 °C, 0 °C, 6 °C and 24 °C upon storage for one year.

18 citations


Journal ArticleDOI
TL;DR: The reverse-phase high performance liquid chromatography method for determining the amounts BZ-3 and its metabolite 2,4-dihydroxybenzophenone (DHB) in human urine was developed and was suitable for use when a large number of samples need to be analyzed.
Abstract: BackgroundBenzophenone-3 (BZ-3) is a common ultraviolet (UV) absorbing compound in sunscreens. It is the most bioavailable species of all UV-absorbing compounds after topical application and can be found in plasma and urine.ObjectivesThe aim of this study was to develop a reverse-phase high performance liquid chromatography (HPLC) method for determining the amounts BZ-3 and its metabolite 2,4-dihydroxybenzophenone (DHB) in human urine. The method had to be suitable for handling a large number of samples. It also had to be rapid and simple, but still sensitive, accurate and reproducible. The assay was applied to study the urinary excretion pattern after repeated whole-body applications of a commercial sunscreen, containing 4% BZ-3, to 25 healthy volunteers.MethodsEach sample was analyzed with regard to both conjugated/non-conjugated BZ-3 and conjugated/non-conjugated DHB, since both BZ-3 and DHB are extensively conjugated in the body. Solid-phase extraction (SPE) with C8 columns was followed by reverse-pha...

17 citations


Journal ArticleDOI
TL;DR: Four simple, rapid and sensitive spectrophotometric methods have been proposed for the determination of enalapril maleate in pharmaceutical formulations and results of analysis are validated statistically.
Abstract: Four simple, rapid and sensitive spectrophotometric methods have been proposed for the determination of enalapril maleate in pharmaceutical formulations. The first method is based on the reaction of carboxylic acid group of enalapril maleate with a mixture of potassium iodate (KIO3) and iodide (KI) to form yellow colored product in aqueous medium at 25 ± 1°C. The reaction is followed spectrophotometrically by measuring the absorbance at 352 nm. The second, third and fourth methods are based on the charge transfer complexation reaction of the drug with p-chloranilic acid (pCA) in 1, 4-dioxan-methanol medium, 2, 3-dichloro 5, 6-dicyano 1, 4-benzoquinone (DDQ) in acetonitrile-1,4 dioxane medium and iodine in acetonitrile-dichloromethane medium. Under optimized experimental conditions, Beer’s law is obeyed in the concentration ranges of 2.5–50, 20–560, 5–75 and 10–200 μg mL−1, respectively. All the methods have been applied to the determination of enalapril maleate in pharmaceutical dosage forms. Results of analysis are validated statistically.

16 citations


Journal ArticleDOI
TL;DR: The proposed spectrofluorimetric method based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium to form a highly fluorescent derivative allowed its successful application to the analysis of P XT in spiked human plasma.
Abstract: New simple spectrofluorimetric method with enhanced sensitivity has been developed and validated for the determination of the antidepressant paroxetine (PXT) in its dosage forms and plasma The method was based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium (pH 8) to form a highly fluorescent derivative that was measured at 545 nm after excitation at 490 nm The factors affecting the reaction was carefully studied and optimized The kinetics of the reaction was investigated, and the reaction mechanism was presented Under the optimized conditions, linear relationship with good correlation coefficient (09993) was found between the fluorescence intensity and PXT concentration in the range of 80–800 ng ml−1 The limits of detection and quantitation for the method were 25 and 77 ng ml−1, respectively The precision of the method was satisfactory; the values of relative standard deviations did not exceed 3% The proposed method was successfully applied to the determination of PXT in its pharmaceutical tablets with good accuracy; the recovery values were 1002 ± 161% The results obtained by the proposed method were comparable with those obtained by the official method The proposed method is superior to the previously reported spectrofluorimetric method for determination of PXT in terms of its higher sensitivity and wider linear range The high sensitivity of the method allowed its successful application to the analysis of PXT in spiked human plasma The proposed method is practical and valuable for its routine application in quality control and clinical laboratories for analysis of PXT

16 citations


Journal ArticleDOI
TL;DR: The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.
Abstract: A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5) to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C18 reversed phase column (4.6 × 150 mm, 3.5 µ m), using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5) delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (λexcitation = 300 nm, λemission = 418 nm). The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error) were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation) was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD) and the limit of quantification (LOQ) of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.

13 citations


Journal ArticleDOI
TL;DR: It is indicated that it is possible to detect phosphorylated peptides with out the loss of phosphate group by MALDI TOF as well as MAL DI TOF TOF instruments with delayed extraction and in the reflector mode.
Abstract: Phosphopeptides with one and four phosphate groups were characterized by MALDI mass spectrometry. The molecular ion of monophosphopeptide could be detected both as positive and negative ions by MALDI TOF with delayed extraction (DE) and in the reflector mode. The tetraphospho peptide could be detected in linear mode. When MS/MS spectra of the monophospho peptides were obtained in a MALDI TOF TOF instrument by CID, b and y ions with the intact phosphate group were observed, in addition the b and y ions without the phosphate group. Our study indicates that it is possible to detect phosphorylated peptides with out the loss of phosphate group by MALDI TOF as well as MALDI TOF TOF instruments with delayed extraction and in the reflector mode.

10 citations


Journal ArticleDOI
TL;DR: The proposed method was successfully used in the determination of gold in several standard reference materials, environmental water samples (potable and polluted, and biological samples (blood and urine), geological, soil and complex synthetic mixtures, and results obtained agree well with those samples analyzed by atomic absorption spectrophotometry (AAS).
Abstract: A simple high sensitive, selective, and rapid spectrophotometric method for the determination of trace gold based on the rapid reaction of gold(III) with bis(salicylaldehyde)orthophenylenediamine (BSOPD) in aqueous and micellar media has been developed. BSOPD reacts with gold(III) in slightly acidic solution to form a 1:1 brownish-yellow complex, which has an maximum absorption peak at 490 nm in both aqueous and micellar media. The most remarkable point of this method is that the molar absorptivities of the gold-BSOPD complex form in the presence of the nonionic TritonX-100 surfactant are almost a 10 times higher than the value observed in the aqueous solution, resulting in an increase in the sensitivity and selectivity of the method. The apparent molar absorptivities were found to be 2.3 × 104 L mol−1 cm−1 and 2.5 × 105 L mol−1 cm−1 in aqueous and micellar media, respectively. The reaction is instantaneous and the maximum absorbance was obtained after 10 min at 490 nm and remains constant for over 24 h at room temperature. The linear calibration graphs were obtained for 0.1 –30 mg L−1 and 0.01 –30 mg L−1 of gold(III) in aqueous and surfactant media, respectively. The interference from over 50 cations, anions and complexing agents has been studied at 1 mg L−1 of Au(III); most metal ions can be tolerated in considerable amounts in aqueous micellar solutions. The Sandell’s sensitivity, the limit of detection and relative standard deviation (n = 9) were found to be 5 ng cm−2, 1 ng mL−1 and 2%, respectively in aqueous micellar solutions. Its sensitivity and selectivity are remarkably higher than that of other reagents in the literature. The proposed method was successfully used in the determination of gold in several standard reference materials (alloys and steels), environmental water samples (potable and polluted), and biological samples (blood and urine), geological, soil and complex synthetic mixtures. The results obtained agree well with those samples analyzed by atomic absorption spectrophotometry (AAS).

10 citations


Journal ArticleDOI
TL;DR: A validated high-performance liquid chromatographic (HPLC) method for determination of phenytoin (PHN), para-hydroxy metabolite ofpheny toin (POH) and sildenafil (SIL) in rabbit plasma is described, fully validated for linearity and range, selectivity, precision, stability, recovery, and robustness.
Abstract: A validated high-performance liquid chromatographic (HPLC) method for determination of phenytoin (PHN), para-hydroxy metabolite of phenytoin (POH) and sildenafil (SIL) in rabbit plasma is described. The method is based on extraction on Sep-Pak C18 solid support using ethyl acetate and ether as eluents and monitoring at 220 nm. The extracted samples were analyzed by HPLC using Agilent Zorbax Extended C18 column (150 mm × 4.6 mm internal diameter) and isocratic elution with a mobile phase consist of 29% acetonitrile and 71% sodium acetate solution (0.02 M, pH 4.6). The method was fully validated for linearity and range, selectivity, precision, stability, recovery, and robustness. The linearity of the method was in the range of 0.15 to 39 μg /ml for PHN and 0.15 to 33 μg/ml for both POH and SIL. Limits of detection (LOD) of PHN, POH, and SIL were 0.15 ± 0.01, 0.15 ± 0.01, and 0.15 ± 0.01 μg/ml, respectively. The % recovery of PHN, POH, and SIL from rabbit plasma were, 101.88 ± 0.12, 99.16 ± 0.25, and 99.49 ± 0.33, respectively. The method was applied on plasma collected from rabbits at different time intervals after receiving 30 mg/kg PHN-Na with (and without) 8 mg/kg SIL citrate.

Journal ArticleDOI
TL;DR: There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage.
Abstract: Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD), Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressure, inflammatory markers and cardiovascular mortality and morbidity were correlated with urine albumin analysed with a point-of-care testing (POCT) instrument, nephelometric determination of albumin and albumin/creatinine ratio in elderly males. The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years) in a cross-sectional study. We analyzed urine albumin with a HemoCue® Urine Albumin POCT instrument and a ProSpec® nephelometer and albumin/creatinine ratio. There were strong correlations between both systolic and diastolic blood pressure and all three urine albumin methods (p < 0.0001). There were also significant correlations between the different urine albumin measurements and serum amyloid A component, high-sensitivity C-reactive protein and interleukin-6. The three different urine albumin methods studied provided similar information in relation to cardiovascular disease. There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage. The good correlation between the studied urine albumin measurements show that all three methods can be used for monitoring urine albumin excretion.

Journal ArticleDOI
TL;DR: Sensitivity achieved in this method is sufficient to perform kinetic studies in humans and good linearity, accuracy, precision, robustness and ruggedness were achieved and detection limits were obtained.
Abstract: Micellar electrokinetic chromatography (MEKC) was investigated for the simultaneous determination of letrozole, imipramine and their metabolites in human urine samples over a concentration range of therapeutic interest. Experimental parameters such as pH of the running electrolyte, sodium dodecylsulphate (SDS) concentration, borate concentration, voltage, etc were investigated. Under optimal conditions of 25 mM SDS, 15 mM borate buffer (pH 9.2), 15% 2-propanol, as back- ground electrolyte; 28 kV and 40 oC, as voltage and cartridge temperature, respectively; resolution between the peaks was greater than 1.7. Before the determination, a solid phase extraction (SPE) procedure with a C18 cartridge was optimized. Good linearity, accuracy, precision, robustness and ruggedness were achieved and detection limits of 12.5 ng/mL for letrozole and its metabolite and 37.5 ng/mL, were obtained for imipramine and their metabolites. Real determinations of these analytes in two patient urines were carried out. Sensitivity achieved in this method is sufficient to perform kinetic studies in humans.

Journal ArticleDOI
TL;DR: The development of stable isotope dilution mass spectrometry for quantifying mevalonate and oxysterols in biological materials is reviewed, and the usefulness of this technique is demonstrated.
Abstract: For more than a decade, we have developed stable isotope dilution mass spectrometry methods to quantify key intermediates in cholesterol and bile acid biosynthesis, mevalonate and oxysterols, respectively. The methods are more sensitive and reproducible than conventional radioisotope (RI), gas-chromatography (GC) or high-performance liquid chromatography (HPLC) methods, so that they are applicable not only to samples from experimental animals but also to small amounts of human specimens. In this paper, we review the development of stable isotope dilution mass spectrometry for quantifying mevalonate and oxysterols in biological materials, and demonstrate the usefulness of this technique.