scispace - formally typeset
Journal ArticleDOI

Heat Transfer Characteristics of One-and Two-Tube-Pass Split-Flow Heat Exchangers

K. N. Murty
- 01 Dec 1983 - 
- Vol. 4, Iss: 3, pp 26-34
TLDR
In this article, the heat transfer process in a split-flow heat exchanger designated as G type by TEMA standards is analyzed for two cases: with one tube pass and with two tube passes.
Abstract
The heat transfer process in a split-flow heat exchanger designated as G type by TEMA standards is analyzed for two cases: with one tube pass and with two tube passes. Equations are presented for the shell fluid temperature distribution as a function of exchanger length or surface area. The thermal performance of the two-tube-pass exchanger is compared with those of a 1:1 counterflow exchanger and a one-pass split-flow exchanger. Results are presented in terms of temperature efficiency, reduced thermal flux (NTU), and thermal flow rate ratio.

read more

Citations
More filters
Journal ArticleDOI

Thermal performance of split-flow heat exchangers

TL;DR: In this paper, the thermal performance of the split-flow heat exchanger is compared with that of the conventional shell and tube exchanger, and the optimum entrance and exit locations of the shellside flow in the split flow exchanger are discussed.
References
More filters
Book

Process heat transfer

TL;DR: In this article, the authors provide fundamental instruction in heat transfer while employing the methods and language of industry using a course given at the Polytechnic Institute of Brooklyn over a period of years.
Related Papers (5)