Journal ArticleDOI
Horizontally installed cone differential pressure meter wet gas flow performance
Reads0
Chats0
TLDR
In this article, a wet gas response of the horizontally installed cone differential pressure (DP) meter is discussed, considering the significant influence of the liquid properties on wet gas flow patterns and the corresponding influence of flow pattern on the cone DP meter's liquid phase induced gas flow rate prediction error.About:
This article is published in Flow Measurement and Instrumentation.The article was published on 2009-08-01. It has received 49 citations till now. The article focuses on the topics: Wet gas & Separator (oil production).read more
Citations
More filters
Journal ArticleDOI
Orifice plate meter wet gas flow performance
Richard Steven,Andrew Hall +1 more
TL;DR: In this paper, a wet gas flow correlation for 2″ to 4″ orifice plate meters has been developed from multiple data sets from four wet gas test facilities, which corrects the liquid induced gas flow rate error for a known liquid flow rate to ±2% at a 95% confidence level.
Journal ArticleDOI
CFD prediction of the effects of the upstream elbow fittings on the performance of cone flowmeters
TL;DR: In this article, the effect of elbow fittings on the discharge coefficient of a cone flowmeter was investigated using an RNG k-e turbulence model with a wide range of Reynolds numbers.
Journal ArticleDOI
A combination method for metering gas–liquid two-phase flows of low liquid loading applying ultrasonic and Coriolis flowmeters
TL;DR: In this article, a new method for measuring the individual mass flowrate of gas-liquid two-phase flow of low liquid loading was proposed based on the combination of ultrasonic and Coriolis flowmeters.
Journal ArticleDOI
Horizontal oil–water two-phase flow measurement with information fusion of conductance ring sensor and cone meter
TL;DR: In this article, an information fusion between the conductance-ring sensor and the cone meter is proposed to measure phase fraction, overall and individual flow rate of oil-water two-phase flow.
Journal ArticleDOI
A new correlation for wet gas flow rate measurement with Venturi meter based on two-phase mass flow coefficient
Denghui He,Bofeng Bai +1 more
TL;DR: In this article, a new correlation for wet gas flow rate measurement with Venturi meter based on a two-phase mass flow coefficient was proposed, which linearly increases with the Lockhart-Martinelli parameter and decreases with the increase of the gas-to-liquid density ratio.
References
More filters
Journal ArticleDOI
A model for predicting flow regime transitions in horizontal and near horizontal gas-liquid flow
Yemada Taitel,A. E. Dukler +1 more
TL;DR: In this article, a generalized flow regime map based on this theory is presented, which is used for determining flow regime transitions in two-phase gas-liquid flow, and the mechanisms for transition are based on physical concepts and are fully predictive.
Journal ArticleDOI
Research Note: Two-Phase Flow through Sharp-Edged Orifices:
TL;DR: In this article, the velocity ratio is assumed to be constant during flow through the orifice, and on this basis analysis of the data leads to the following equations for velocity ratio: for X ≥ 1, K = (pL/pHOM)1/2 for X ≤ 1,
Journal ArticleDOI
Flow of Incompressible Two-Phase Mixtures through Sharp-Edged Orifices:
TL;DR: In this paper, the authors developed an equation for the flow of gas-liquid or vapour-liquid mixtures through sharp-edged orifices under conditions where the density change of the gas or liquid through the orifice is negligible.
Journal ArticleDOI
Orifice plate meter wet gas flow performance
Richard Steven,Andrew Hall +1 more
TL;DR: In this paper, a wet gas flow correlation for 2″ to 4″ orifice plate meters has been developed from multiple data sets from four wet gas test facilities, which corrects the liquid induced gas flow rate error for a known liquid flow rate to ±2% at a 95% confidence level.