Pressure Drop due to Friction for Parallel Flow of Mixtures of Vapour and Water in a Downcomer
TLDR
In this article, the authors experimentally investigated the pressure drop due to friction for the flow of water containing bubbles in a non-heated downcomer and derived the ratio of the coefficient of friction in high pressure regions.Abstract:
In this paper, the author experimentally investigated the pressure drop due to friction for the flow of water containing bubbles in a non-heated downcomer. First, the pressure drop due to friction and dryness fraction for the parallel downward flow of the mixtures of air and water were measured in a vertical 1500 mm long and 19 mm inside diameter glass pipe. Next, the ratios of the coefficient of friction in high pressure regions were extensively computed from the results of the above experiment. Finally, in case we used nonheated downcomer, it was proposed that we might adopt 0.03 as an approximate value of the coefficient of friction.read more
Citations
More filters
Journal ArticleDOI
Sparged loop reactors