Reliability of a human pose tracking algorithm for measuring upper limb joints: comparison with photography-based goniometry

Reads0
Chats0
TLDR
Li et al. as discussed by the authors evaluated if the results of the pose tracking algorithm are as reliable as human raters in upper limb movements. But, the reliability of this method has not been fully established.
Abstract
Abstract Background Range of motion (ROM) measurements are essential for diagnosing and evaluating upper extremity conditions. Clinical goniometry is the most commonly used methods but it is time-consuming and skill-demanding. Recent advances in human tracking algorithm suggest potential for automatic angle measuring from RGB images. It provides an attractive alternative for at-distance measuring. However, the reliability of this method has not been fully established. The purpose of this study is to evaluate if the results of algorithm are as reliable as human raters in upper limb movements. Methods Thirty healthy young adults (20 males, 10 females) participated in this study. Participants were asked to performed a 6-motion task including movement of shoulder, elbow and wrist. Images of movements were captured by commercial digital cameras. Each movement was measured by a pose tracking algorithm (OpenPose) and compared with the surgeon-measurement results. The mean differences between the two measurements were compared. Pearson correlation coefficients were used to determine the relationship. Reliability was investigated by the intra-class correlation coefficients. Results Comparing this algorithm-based method with manual measurement, the mean differences were less than 3 degrees in 5 motions (shoulder abduction: 0.51; shoulder elevation: 2.87; elbow flexion:0.38; elbow extension:0.65; wrist extension: 0.78) except wrist flexion. All the intra-class correlation coefficients were larger than 0.60. The Pearson coefficients also showed high correlations between the two measurements ( p < 0.001). Conclusions Our results indicated that pose estimation is a reliable method to measure the shoulder and elbow angles, supporting RGB images for measuring joint ROM. Our results presented the possibility that patients can assess their ROM by photos taken by a digital camera. Trial registration This study was registered in the Clinical Trials Center of The First Affiliated Hospital, Sun Yat-sen University (2021–387).

read more

Citations
More filters
Journal ArticleDOI

Digital health in musculoskeletal care: where are we heading?

TL;DR: BMC Musculoskeletal Disorders launched a collection on digital health to get a sense of where the wind is blowing, and what impact these technologies are and will have on musculo-keletal medicine as discussed by the authors .
Journal ArticleDOI

Development of Serious Games for the Rehabilitation of the Human Vertebral Spine for Home Care

TL;DR: In this paper , the authors developed aesthetically pleasing, smooth, and attractive games, while maintaining the essence of seriousness that is required for rehabilitation, to assist health professionals in the physiotherapy of patients with spinal pain for clinical and home applications.
Journal ArticleDOI

The reliability and validity of joint range of motion measurement using zoom and a smartphone application

TL;DR: In this article , the authors evaluated the reliability and validity of measuring the range of motion of joints using a remote videoconferencing system (Zoom) and a smartphone application.
Journal ArticleDOI

Reproducibility and validity of knee joint position estimation using markerless motion capture

TL;DR: In this paper , the authors propose a framework called FTA (FTA-FTA), which is an extension of FTA-GCC, and achieve 0.4±0.6歳: 0.74,0.97) r=0.74 ,p <0.01< 0.
References
More filters
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement.

TL;DR: An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement

TL;DR: In this article, an alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability, which is often used in clinical comparison of a new measurement technique with an established one.
Journal ArticleDOI

OpenPose: Realtime Multi-Person 2D Pose Estimation Using Part Affinity Fields

TL;DR: OpenPose as mentioned in this paper uses Part Affinity Fields (PAFs) to learn to associate body parts with individuals in the image, which achieves high accuracy and real-time performance.
Journal ArticleDOI

Reliability of goniometric measurements.

TL;DR: The intratester and intertester variability and reliability of goniometric measurements taken by four physical therapists on upper and lower extremity motions of normal male subjects indicate the necessity for using the same tester when effects of treatment are evaluated.
Journal ArticleDOI

Reliability of five methods for assessing shoulder range of motion.

TL;DR: Inter-rater and intra- rater agreement trials were undertaken to ascertain the reliability of visual estimation, goniometry, still photography, "stand and reach" and hand behind back reach for six different shoulder movements.