Proceedings ArticleDOI
Standalone solar PV array fed SMC based PMSM driven water pumping system
Reads0
Chats0
TLDR
A sliding mode control (SMC) based vector control of permanent magnet synchronous motor (PMSM) drive used in solar water pumping system is presented and gives good performance under system parameter variations, load disturbances and sudden change in reference speed.Abstract:
A sliding mode control (SMC) based vector control of permanent magnet synchronous motor (PMSM) drive used in solar water pumping system is presented in this paper. The SMC gives good performance for motor-drive system under system parameter variations, load disturbances and sudden change in reference speed. The solar PV array is operated at maximum power point through a boost converter. The DC bus voltage of the system is held constant through the DC link voltage proportional-integral (PI) controller. The output of DC link voltage PI controller and the PV array feed forward term are used to generate reference speed command. The speed of PMSM is controlled through vector control. Switching signals for voltage source inverter (VSI) are generated using the hysteresis current controller. The proposed system is designed, modeled and simulated on MATLAB/Simulink platform. The starting, steady-state and dynamic performances of the system are examined for variable environmental conditions. A prototype of the system is also developed in the laboratory.read more
Citations
More filters
Journal ArticleDOI
Standalone photovoltaic array fed induction motor driven water pumping system
TL;DR: In this paper, the output power of a PV solar cell is fully used by proposing the P&O algorithm, where it is used to follow a maximum power point tracking (MPPT) technique.
Current Fed Switched Inverter Using Sliding Mode Controller (SMC) For Grid Application
Goba Galma,Balachandra Pattanaik +1 more
TL;DR: For the grid applications, the current fed switched inverter (CFSI) is designed to distribute the energy using the Photo-Voltaic system, which has high gain generation ratio and using less passive components.
Proceedings ArticleDOI
Adaptive SMC Based DTC of Position Sensorless PMSM Driven Solar PV Water Pumping System
TL;DR: An adaptive sliding mode controller (ASMC) based direct torque control of position sensorless permanent magnet synchronous motor (PMSM) driven single stage solar photovoltaic water pumping system is proposed and an ASMC based DTC is used as it reduces the influence of external disturbances and parameter variations on the proposed system.
Journal ArticleDOI
Optimization of Photovoltaic Water Pumping System Based on BLDC Motor for Agricultural Irrigation with Different MPPT Methods
TL;DR: In this paper , the authors presented a comparative analysis of different MPPT techniques for PV array fed water pumping system without batteries using brushless direct current (BLDC) motor, the system is configured to reduce both cost and complexity with simultaneous assurance of optimum power utilization of PV array.
References
More filters
Book
Sensorless vector and direct torque control
TL;DR: This paper presents a space-phasor model of A.C. machines based on artificial intelligence-based steady-state and transient analysis of electrical machines, estimators and investigates the role of magnetic saturation in the control of these machines.
Journal ArticleDOI
Maximum photovoltaic power tracking: an algorithm for rapidly changing atmospheric conditions
TL;DR: In this article, the authors developed an incremental conductance (IncCond) algorithm to track the maximum power operating point (MPOP) of photovoltaic (PV) power generation systems.
Book
Permanent Magnet Synchronous and Brushless DC Motor Drives
TL;DR: In this article, the authors present a real-time model of a two-phase PMSM transformation to rotor reference frames, where the PMSMs are used to estimate the position of the rotors.
Book
Pulse-width modulated DC-DC power converters
TL;DR: In this paper, the authors present a classification of power supplies in DC-DC Converters, including voltage, current, voltage, energy, and power, and discuss the relationship among them.
Journal ArticleDOI
Assessment of Perturb and Observe MPPT Algorithm Implementation Techniques for PV Pumping Applications
TL;DR: In this article, a detailed theoretical and experimental comparison of the two perturb and observe (P&O) implementation techniques on the basis of system stability, performance characteristics, and energy utilization for standalone PV pumping systems is presented.
Related Papers (5)
Double stage solar PV array fed water pump driven by permanent magnet synchronous motor
Shadab Murshid,Bhim Singh +1 more
Simulation and hardware implementation of PMSM driven solar water pumping system