The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities.

Reads0
Chats0
TLDR
In this paper, the authors compare depth-dose profiles in an Alderson Rando phantom and a similarly shaped phantom of water which closely simulates the attenuation properties of human muscle.
Abstract
Comparative measurements were made of depth-dose profiles in an Alderson Rando phantom and a similarly shaped phantom of water which closely simulates the attenuation properties of human muscle. Measurements were carried out at three different kV settings of the X-ray generator, covering the lower-energy range of normal diagnostic practice over which attenuation differences are likely to be most important. The results show that whilst the Alderson phantom can undoubtedly be extremely useful in medical dosimetry, corrections to the dose distributions observed for diagnostic qualities of radiation may sometimes be necessary to allow for departures from tissue-equivalence.

read more

Citations
More filters
Journal ArticleDOI

Dose reduction in maxillofacial imaging using low dose Cone Beam CT

TL;DR: The use of CBCT for maxillofacial imaging results in a reduced absorbed and effective dose and the use of lead shielding leads to a further reduction of the absorbed doses of thyroid and cervical spine, as well as the effective dose.
Journal ArticleDOI

Advances in kilovoltage x-ray beam dosimetry

TL;DR: This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry and provides recommendations for clinical measurements based on the literature to date.
Journal ArticleDOI

Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations.

TL;DR: Although doses from child DXA examinations are low, it is still important to keep them as small as possible by setting appropriate values of the scan length before scan acquisition and by avoiding mistakes that lead to scans having to be unnecessarily repeated.
Journal ArticleDOI

Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality

TL;DR: The observed reduction of organ dose and total energy imparted could be achieved more efficiently by a reduction of tube current, and the application of in-plane selective shielding is therefore discouraged.
Journal ArticleDOI

16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation

TL;DR: Estimating CT dose on a 16-detector unit directly using thermoluminescent dosemeters (TLDs) and an anthropomorphic phantom found that the dose measured directly was 18% higher than the computer simulated dosimetry, in keeping with the previously recognised underestimation by computer simulation techniques compared with TLD measurements.
References
More filters
Journal ArticleDOI

Tissue substitutes in experimental radiation physics

TL;DR: In this review of tissue substitute materials, the historical development of the important systems is traced from the early 1900's and recommendations of systems having useful simulation properties are given.
Journal ArticleDOI

A TLD system based on lithium borate for the measurement of doses to patients undergoing medical irradiation

TL;DR: Preliminary measurements on solid glassy discs of lithium borate suggest that this form of the material may in some respects be superior for patient dosimetry, suggesting its closer approximation to soft tissue and its low cost.