scispace - formally typeset
Proceedings ArticleDOI

Wind power plant from air conditioning exhaust using L Savonius wind turbine

Langlang Gumilar, +3 more
- Vol. 2097, Iss: 1, pp 030036
TLDR
In this article, a wind turbine is placed in front of the air conditioner blower, then the turbine is combined with the generator to convert residual wind from air conditioning to electrical energy again.
Abstract
Renewable energy is now a trending topic in research as a source of energy that free of pollution and alternative energy sources to substitute fossil energy sources. Research on renewable energy has always been developed to support energy security. Wind is one of the renewable energy sources that can be utilized to generate electrical energy. In this research will converting residual wind from air conditioning to electrical energy again. The advantage of using the exhaust from the air conditioning blower is that it has a relatively stable wind speed every time, although not as big as wind speeds available in nature. From the measurement with anemometer obtained the greatest wind speed is 6 m/s when its distance of 4 cm from the blower, and power of air conditioner 2,5 horsepower (HP) at temperature 16°C. Turbine can convert wind energy into electrical energy. The wind turbine is placed in front of the air conditioner blower, then the turbine is combined with the generator. Wind output from the blower is spread in all way, so made turbine type L Savonius. Generators used are a direct current generator (DC) and alternating current generator (AC). At the time testing, used Air Conditioner with power 0,5 HP, 1 HP, and 2,5 HP. In the test with air conditioner 0,5 HP obtained output voltage from the ac generator is 19,5 V and current is 0,65 A. Test using dc generator get output voltage is 35 V and the current is 0,37 A. In the test with air conditioner 1 HP obtained output voltage from the ac generator is 24 V and current is 0,52 A. Test using dc generator get output voltage is 37 V and current is 0,34 A. In the test with air conditioner 2,5 HP obtained output voltage from the ac generator is 24 V and current is 0,53 A. Test using dc generator get output voltage is 38 V and current is 0,34 A. Value of the output voltage of the generator is influenced by the amount of AC power consumption. Amount of voltage generated by the generator may can be used to turn on the surface-mount device light-emitting diode (SMD LED).

read more

Citations
More filters
Proceedings ArticleDOI

Analysis of Short Circuit on Four Types Wind Power Plants as Distributed Generation

TL;DR: The contribution of this paper to analyze the effect of wind power plants’ existence as distributed generation (DG) to short circuit currents in electrical power systems to testing of short circuit simulation on the IEEE 69 bus standard.
Proceedings ArticleDOI

Optimalization harmonic shunt passive filter using detuned reactor and capacitor bank to improvement power quality in hybrid power plant

TL;DR: In this paper, an optimal shunt passive filter using detuned reactors and capacitors bank was proposed to mitigate harmonics with fluctuate and dominant harmonic orders that change as well as in harmonic active filters.
Proceedings ArticleDOI

P-V and Q-V Curve Analysis of Four Types Wind Power Plants at Battery Charging Station

TL;DR: In this paper, the authors discussed how to maintain the stability of the bus voltage by interconnecting the wind power plant (WPP) with battery charging station (BCS).
Proceedings ArticleDOI

Analysis Voltage Stability in the Interconnection of Battery Charging Station and Renewable Energy

TL;DR: In this article, the authors examined voltage stability following BCS interconnection with electrical power systems and renewable energy using the IEEE 14 bus standard, which is the electric power system used in order to boost voltage instability and the function of distributed generation.
Proceedings ArticleDOI

Power Quality Enhancement on Hybrid Power Plants Using Shunt Passive Power Filter and Detuned Reactor

TL;DR: It can be concluded that the role of the detuned reactor can improve the performance of shunt passive filters.
References
More filters
Journal ArticleDOI

Turbine Stability-Constrained Available Wind Power of Variable Speed Wind Turbines for Active Power Control

TL;DR: In this paper, the turbine stability-constrained available wind power is defined and analyzed to sustain the power generation of scheduled wind turbines at a maximum level, and simulation results show that the VSWT dispatched according to the proposed AWP can maintain stable power generation with less pitch action and therefore better support secure and economic power system operations.
Proceedings ArticleDOI

Modular structure of wind turbine models in IEC 61400-27-1

TL;DR: In this paper, the modular structure of wind turbine models is described in a new standard IEC 61400-27 for electrical simulation models for wind power generation, which is intended for short-term power system stability analyses.
Book

Renewable Energy: A First Course

TL;DR: In this paper, the authors provide an in-depth introduction to renewable energy science, focusing mainly on renewable energy, but also addressing non-renewable energy (fossil fuels and nuclear technology).
Proceedings ArticleDOI

Study on modeling and simulation of non-grid-connected wind turbine

TL;DR: In this paper, the authors make an analysis on different methods for modeling non-grid-connected wind turbines, including rotor, transmission system and generator, based on the data gained from experiment, a model of small wind turbine is presented using system identification.
Proceedings ArticleDOI

Analysis of the passive yaw mechanism of small horizontal-axis wind turbines

TL;DR: In this article, the authors compared different passive yaw control mechanisms by considering both their technical viabilities and costs, and concluded that small wind turbines with a tilting tail hinge and an offset pivot axis are simpler and more economical than other passive-yaw-control small turbines.
Related Papers (5)