A
Anna Bergamaschi
Researcher at Paul Scherrer Institute
Publications - 106
Citations - 3348
Anna Bergamaschi is an academic researcher from Paul Scherrer Institute. The author has contributed to research in topics: Detector & Photon counting. The author has an hindex of 26, co-authored 99 publications receiving 2959 citations. Previous affiliations of Anna Bergamaschi include University of Trieste.
Papers
More filters
Journal ArticleDOI
Performance of single-photon-counting PILATUS detector modules
P. Kraft,Anna Bergamaschi,Ch. Broennimann,Roberto Dinapoli,E. F. Eikenberry,B. Henrich,Ian Johnson,Aldo Mozzanica,Christian M. Schlepütz,Philip R. Willmott,Bernd Schmitt +10 more
TL;DR: Characterization of PILATUS single-photon-counting X-ray detector modules regarding charge sharing, energy resolution and rate capability is presented and the performance of the detector was tested with surface diffraction experiments at the synchrotron.
Journal ArticleDOI
PILATUS: A single photon counting pixel detector for X-ray applications
B. Henrich,Anna Bergamaschi,Ch. Broennimann,Roberto Dinapoli,E. F. Eikenberry,Ian Johnson,M. Kobas,P. Kraft,Aldo Mozzanica,Bernd Schmitt +9 more
TL;DR: The PILATUS hybrid pixel detector as discussed by the authors combines silicon sensors with CMOS processing chips by a 2D micro bump-bonding interconnection technology developed at the Paul Scherrer Institute.
Journal ArticleDOI
The Materials Science beamline upgrade at the Swiss Light Source
Philip R. Willmott,D. Meister,Steven J. Leake,M. Lange,Anna Bergamaschi,M. Böge,Marco Calvi,Claudia Cancellieri,Nicola Casati,Antonio Cervellino,Q. Chen,Christian David,Uwe Flechsig,Fabia Gozzo,B. Henrich,S. Jäggi-Spielmann,B. Jakob,Irakli Kalichava,Petri Karvinen,J. Krempasky,A. Lüdeke,R. Lüscher,S. Maag,Christoph Quitmann,M. L. Reinle-Schmitt,Thomas J. Schmidt,Bernd Schmitt,Andreas Streun,Ismo Vartiainen,M. Vitins,X. Wang,R. J. Wullschleger +31 more
TL;DR: The wiggler X-ray source of the Materials Science beamline at the Swiss Light Source has been replaced with a 14 mm-period cryogenically cooled in-vacuum undulator to best exploit the increased brilliance of this new source.
Journal ArticleDOI
The MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source
Anna Bergamaschi,Antonio Cervellino,Roberto Dinapoli,Fabia Gozzo,B. Henrich,Ian Johnson,P. Kraft,Aldo Mozzanica,Bernd Schmitt,Xintian Shi +9 more
TL;DR: A report on the characterization, calibration and performances of the MYTHEN photon-counting silicon microstrip detector at the powder diffraction station at the Swiss Light Source is given.
Journal ArticleDOI
Characterization and Calibration of PILATUS Detectors
P. Kraft,Anna Bergamaschi,Christian Brönnimann,Roberto Dinapoli,E. F. Eikenberry,H. Graafsma,B. Henrich,Ian Johnson,M. Kobas,Aldo Mozzanica,Christian M. Schlepütz,Bernd Schmitt +11 more
TL;DR: Pilatus as discussed by the authors is a silicon hybrid pixel detector system for detecting X-rays in single photon counting mode, which is suitable for various X-ray applications such as diffraction and imaging techniques.