scispace - formally typeset
Search or ask a question

Showing papers by "Gabriel Blaj published in 2015"


Journal ArticleDOI
TL;DR: An overview of area detectors developed for use at the Linac Coherent Light Source (LCLS) with particular emphasis on their impact on science is offered.
Abstract: Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

104 citations


ReportDOI
P. Abbamonte1, F. Abild Pedersen, Paul D. Adams2, Musa Ahmed2  +203 moreInstitutions (47)
01 Jun 2015

50 citations


Journal ArticleDOI
TL;DR: In this article, the authors present the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance, showing that the newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged.
Abstract: The Medipix3RX is the latest version of the Medipix3 photon counting ASICs, which implements two new operational modes, with respect to the Medipix2 ASIC, aimed at eliminating charge shared events (referred to as Charge Summing Mode (CSM)) and at providing spectroscopic information (referred to as Colour Mode (CM)). The Medipix3RX is a redesign of the Medipix3v0 ASIC and corrects for the underperformance of CSM features observed in the previous version. This paper presents the results from synchrotron X-rays tests to evaluate the Medipix3RX ASIC performance. The newly implemented CSM algorithm eliminates the charge sharing effect at the same time as allocating the event to the readout pixel corresponding to the sensor pixel where the X-ray photon impinged. The new pixel trimming circuit led to a reduced dispersion between pixels. Further results of the linearity for all the gain modes, energy resolution and pixel uniformity are also presented.

18 citations


Proceedings ArticleDOI
TL;DR: ePix10k as discussed by the authors is a variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras.
Abstract: ePix10k is a variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras The ASIC is optimized for high dynamic range application requiring high spatial resolution and fast frame rates ePix ASICs are based on a common platform composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog to digital converters per column The ePix10k variant has 100um×100um pixels arranged in a 176×192 matrix, a resolution of 140e- rms and a signal range of 35pC (10k photons at 8keV) In its final version it will be able to sustain a frame rate of 2kHz A first prototype has been fabricated and characterized Performance in terms of noise, linearity, uniformity, cross-talk, together with preliminary measurements with bump bonded sensors are reported here

2 citations


06 Aug 2015
TL;DR: Free Electron Lasers opened a new window on imaging the motion of atoms and molecules at SLAC as mentioned in this paper, using 120Hz pulses with 1012 - 1013 photons in 10 femtoseconds.
Abstract: Free Electron Lasers opened a new window on imaging the motion of atoms and molecules. At SLAC, FEL experiments are performed at LCLS using 120Hz pulses with 1012 - 1013 photons in 10 femtoseconds (billions of times brighter than the most powerful synchrotrons). This extreme detection environment raises unique challenges, from obvious to surprising. Radiation damage is a constant threat due to accidental exposure to insufficiently attenuated beam, focused beam and formation of ice crystals reflecting the beam onto the detector. Often high power optical lasers are also used (e.g., 25TW), increasing the risk of damage or impeding data acquisition through electromagnetic pulses (EMP). The sample can contaminate the detector surface or even produce shrapnel damage. Some experiments require ultra high vacuum (UHV) with strict design, surface contamination and cooling requirements - also for detectors. The setup is often changed between or during experiments with short turnaround times, risking mechanical and ESD damage, requiring work planning, training of operators and sometimes continuous participation of the LCLS Detector Group in the experiments. The detectors used most often at LCLS are CSPAD cameras for hard x-rays and pnCCDs for soft x-rays.

2 citations