scispace - formally typeset
Search or ask a question

Showing papers by "N. C. Ryder published in 2018"


Journal ArticleDOI
TL;DR: In this paper, the SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level A 288$\,$kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down.
Abstract: The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level A 288$\,$kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down Dedicated calibration campaigns were also performed with gamma and neutron sources This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/$\sqrt{E(MeV)}$ The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time Particle identification based on pulse-shape discrimination is demonstrated with calibration sources Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment The results obtained with this prototype proved essential in the design optimization of the final detector This paper is dedicated to our SCK$\cdot$CEN colleague, Edgar Koonen, who passed away unexpectedly in 2017 Edgar was part of the SoLid collaboration since its inception and his efforts were vital to get the experiment started He will be duly missed

47 citations


Journal ArticleDOI
TL;DR: In this paper, the SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level.
Abstract: The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288 kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down. Dedicated calibration campaigns were also performed with gamma and neutron sources. This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site. All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/√E(MeV). The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time. Particle identification based on pulse-shape discrimination is demonstrated with calibration sources. Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment. The results obtained with this prototype proved essential in the design optimization of the final detector.

36 citations


Journal ArticleDOI
TL;DR: In this article, the authors present a comprehensive optimisation study to maximize the light collection efficiency of scintillating cube elements used in the SoLid detector, and demonstrate that the required energy resolution of at least 14 % at 1 MeV can be achieved.
Abstract: This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and 6LiF:ZnS(Ag) screens. A precision test bench based on a 207Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1 MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the 6LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52±2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.

15 citations


Journal ArticleDOI
TL;DR: In this article, the authors present a comprehensive optimisation study to maximize the light collection efficiency of scintillating cube elements used in the SoLid detector, and demonstrate that the required energy resolution of at least 14 % at 1 MeV can be achieved.
Abstract: This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and $^6$LiF:ZnS(Ag) screens. A precision test bench based on a $^{207}$Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1~MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the $^6$LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52$\pm$2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.

9 citations


Journal ArticleDOI
TL;DR: The SoLid detector as discussed by the authors uses a combination of high-performance FPGAs with a gigabit Ethernet-based readout system, and its total power consumption is under 1 kW.
Abstract: The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.

7 citations


Journal ArticleDOI
TL;DR: The SoLid experiment as discussed by the authors was designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium.
Abstract: The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overline{ u}_e$ target for the inverse beta decay of ($\overline{ u}_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overline{ u}_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.

2 citations