T
Tabish Alam
Researcher at Central Building Research Institute
Publications - 63
Citations - 1123
Tabish Alam is an academic researcher from Central Building Research Institute. The author has contributed to research in topics: Nusselt number & Engineering. The author has an hindex of 11, co-authored 21 publications receiving 570 citations. Previous affiliations of Tabish Alam include Kyungpook National University & Academy of Scientific and Innovative Research.
Papers
More filters
Journal ArticleDOI
A comprehensive review on single phase heat transfer enhancement techniques in heat exchanger applications
Tabish Alam,Man-Hoe Kim +1 more
TL;DR: In this article, an effort has been made to categorize the active and passive methods and review the various heat transfer techniques applied in heat exchangers, and a combined method have also been recommended which include both active and active methods.
Journal ArticleDOI
Indoor Air Quality Improvement in COVID-19 Pandemic: Review
Nehul Agarwal,Nehul Agarwal,Chandan Swaroop Meena,Chandan Swaroop Meena,Binju P Raj,Binju P Raj,Lohit Saini,Lohit Saini,Ashok Kumar,Ashok Kumar,N. Gopalakrishnan,N. Gopalakrishnan,Anuj Kumar,Anuj Kumar,Nagesh Babu Balam,Nagesh Babu Balam,Tabish Alam,Tabish Alam,Nishant Raj Kapoor,Nishant Raj Kapoor,Vivek Aggarwal,Vivek Aggarwal +21 more
TL;DR: In this paper, a review of all the possible measures to improve the indoor air quality taking into account the affecting parameters has been done, which can deliberately help in bringing down the impact of declined air quality and prevent future biological attacks from affecting the occupant's health.
Journal ArticleDOI
Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater
TL;DR: In this article, the effect of geometrical parameters of the V-shaped perforated blocks on heat transfer and flow characteristics of rectangular duct, has been investigated experimentally and the experimental investigation encompassed the Geometrical parameter namely, relative blockage height (e / H ) of 04-10, relative pitch ratio ( P / e ) of 4-12 and open area ratio ( β ) of 5-25% at a fixed angle of attack ( α ) of 60°.
Journal ArticleDOI
Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs
Tabish Alam,Man-Hoe Kim +1 more
TL;DR: In this article, the effect of relative ribs pitch and relative ribs height on Nusselt number and friction factor have been studied for the range of Reynolds number from 4000 to 16,000.
Journal ArticleDOI
A critical review on artificial roughness provided in rectangular solar air heater duct
Tabish Alam,Man-Hoe Kim +1 more
TL;DR: In this paper, the Nusselt number and friction factor correlations for various roughness elements have been summarized and a comparison study of thermohydraulic performance of different roughness element has also been reported to understand the results of applications of artificial roughness.