scispace - formally typeset
Search or ask a question

Showing papers by "BIA Separations (Slovenia) published in 2000"


Journal ArticleDOI
TL;DR: A heat release during the polymerization is analyzed and a mathematical model is derived for the prediction of the maximal thickness of the monolithic annulus having a uniform structure for GMA-EDMA monoliths.
Abstract: Monolithic supports have become the subject of extensive study in the past years. Despite their advantageous features and many successful chromatographic applications in the analytical scale, only a very few examples of larger volume monoliths were described. In the case of GMA−EDMA monoliths, this can be attributed to the fact that due to the exothermic polymerization a pronounced temperature increase inside the monolith significantly affects the structure. The temperature increase depends on the thickness of the monolith, and consequently, there is an upper limit that allows the preparation of a unit with a uniform structure. In the present work, we have analyzed a heat release during the polymerization and have derived a mathematical model for the prediction of the maximal thickness of the monolithic annulus having a uniform structure. On the basis of the calculations, two annuluses of different diameters were polymerized and merged into a single monolithic unit with a volume of 80 mL. In addition, a s...

167 citations


Journal ArticleDOI
TL;DR: In this article, the dynamic binding capacity of CIM® monolithic columns has been characterized for different linear velocities, up to a linear velocity of 2450 cm/h. Breakthrough experiments were performed for capacity determination.
Abstract: The characterization of CIM® DEAE monolithic columns in terms of dynamic binding capacity is presented in this paper. Breakthrough experiments were performed for capacity determination. Bovine serum albumin (BSA) was used as a model protein. It is shown that CIM® monolithic columns have good batch-to-batch reproducibility as well as long-term stability. The experiments performed under different linear velocities demonstrated that the dynamic capacity is unaffected at least up to a linear velocity of 2450 cm/h. Furthermore, the breakthrough curve slope is constant, indicating that the capacity would remain constant at even higher linear velocities. The adsorption isotherm of BSA dissolved in 20 mM Tris-HCl buffer shows a constant capacity of around 30 mg/mL of support down to a concentration of 20 μg/mL. The capacity is substantially influenced by the ionic strength; however, 20% of the maximal capacity is still preserved at 0.3 M NaCl.

74 citations


Journal ArticleDOI
TL;DR: The CIM disk applied as an enzyme reactor proved to be a successful replacement for conventionally used packed-bed columns and as such it was well suited for on-line monitoring of bioprocesses.

52 citations


Journal ArticleDOI
TL;DR: This method can be successfully applied not only to an in-process control of the purification of factor IX but also to other biopolymers from human plasma.

33 citations


Journal ArticleDOI
TL;DR: It is demonstrated that citric, isocitric, pyruvic, fumaric, malic, and alpha-ketoglutaric acid can be successfully separated using a CIM monolithic column of suitable user-adjustable length and the dynamic binding capacity is found to be flow-unaffected.
Abstract: The separation of organic acids on the anion-exchange monolithic support, commercially available as Convective Interaction Media (CIM), is presented in this study. It is demonstrated that citric, isocitric, pyruvic, fumaric, malic, and α-ketoglutaric acid can be successfully separated using a CIM monolithic column of suitable user-adjustable length. The effect of the mobile phase composition on the separation is investigated. CIM monolithic columns of adjustable length from 3 to 18 mm are compared regarding the resolution and the back pressure. It is shown that the CIM monolithic column of 12 mm in length enables a good separation of all six organic acids within 3 min and exhibits a linear dependence of back pressure versus flow rate. The resolution and the dynamic binding capacity are found to be flow-unaffected. A filtrated sample of bioprocess supernatant is analyzed without previous pretreatment, which indicates the possibility of online monitoring of small molecules during the bioprocess using CIM monolithic columns.

28 citations