scispace - formally typeset
Search or ask a question

Showing papers in "arXiv: Instrumentation and Detectors in 2005"


Posted Content
TL;DR: In this paper, the analysis of the LPC cluster usage (Clermont-Ferrand, France) in the EGEE Grid environment is done, and from the results a model for job arrival is proposed.
Abstract: With Grids, we are able to share computing resources and to provide for scientific communities a global trans-parent access to local facilities. In such an environment the problems of fair resource sharing and best usage arise. In this paper, the analysis of the LPC cluster usage (Clermont-Ferrand, France) in the EGEE Grid environment is done, and from the results a model for job arrival is proposed

79 citations


Posted Content
TL;DR: The Wide Angle Shower Apparatus (WASA) has been transferred from the storage ring CELSIUS (TSL, Uppsala, Sweden) to the cooler synchrotron COSY (FZ Juelich, Germany) as discussed by the authors.
Abstract: The Wide Angle Shower Apparatus (WASA) has been transferred from the storage ring CELSIUS (TSL, Uppsala, Sweden) to the cooler synchrotron COSY (FZ Juelich, Germany). In this presentation, the status and planning of the WASAatCOSY project are reported. The main physics aspects are rare decays of eta and eta' mesons and isospin violation in deuteron-deuteron interactions.

76 citations


Book ChapterDOI
TL;DR: In this article, the authors discuss performance considerations for near-equilibrium thermal detectors, including optimal filtering and energy resolution calculations, and provide a starting point for a brief discussion of electrothermal feedback, other noise sources, various non-ideal effects, and nonlinearity.
Abstract: Near-equilibrium thermal detectors operate as classical calorimeters, with energy deposition and internal equilibration times short compared to the thermal time constant of the device. Advances in fabrication techniques, cryogenics, and electronics have made it practical to measure deposited energy with unprecedented sensitivity and precision. In this chapter we discuss performance considerations for these devices, including optimal filtering and energy resolution calculations. We begin with the basic theory of simple equilibrium calorimeters with ideal resistive thermometers. This provides a starting point for a brief discussion of electrothermal feedback, other noise sources, various non-ideal effects, and nonlinearity. We then describe other types of thermometers and show how they fit into this theoretical framework and why they may require different optimizations and figures of merit. Most of this discussion is applicable also to power detectors, or bolometers, where the detector time constants may be short compared to variations in the incident signal power.

68 citations


Journal ArticleDOI
TL;DR: In this article, the design of a single beam, multiple species atom source in which the flux of any component can be separately adjusted has been described for ultracold atom experiments.
Abstract: We describe the design of a single beam, multiple species atom source in which the flux of any component can be separately adjusted. Using this design we have developed a 23Na-6Li atom source for ultracold atom experiments. The fluxes of lithium and sodium are independently tunable, allowing operation as a single 23Na or 6Li source as well as a double source with equal atomic fluxes in each component.

46 citations


Journal ArticleDOI
TL;DR: In this paper, the authors proposed a method to improve the sensitivity of the interferometer by 20-30 dB at low-frequency frequencies, which is equivalent to a S/N ratio of 2.5E-6.
Abstract: The measurement of the close-to-the-carrier noise of rf and microwave devices is a relevant issue in time and frequency metrology and in some fields of electronics, physics and optics. While phase noise is the main concern, amplitude noise is often of interest. The highest sensitivity is achieved with the bridge (interferometric) method, which consists of the amplification and synchronous detection of the noise sidebands after suppressing the carrier by vector subtraction of an equal signal. A substantial progress in understanding the flicker noise mechanism of the interferometer results in new schemes that improve by 20--30 dB the sensitivity at low Fourier frequencies. The article provides the complete theory and detailed design criteria, and reports on the implementation of a prototype. In real-time measurements, a background noise of -175 -180 dBrad^2/Hz has been obtained at f=1 Hz off the 100 MHz carrier. Exploiting correlation and averaging in similar conditions, the sensitivity exceeds -185 dBrad^2/Hz at f=1 Hz. A residual noise of -203 dBrad^2/Hz at f=250 Hz off the carrier has been obtained, while the ultimate noise floor is still limited by the averaging capability of the correlator. This is equivalent to a S/N ratio of 2E20 with a frequency spacing of 2.5E-6. Applications include the measurement of the properties of materials and the observation of weak flicker-type physical phenomena, out of reach for other instruments. We measured the flicker noise of a by-step attenuator (-171 dB[rad^2]/Hz at f=1 Hz) and of the ferrite noise of a reactive power divider (-173.7 dB[rad^2]/Hz at f=1 Hz) without need of correlation.

34 citations


Posted Content
TL;DR: In this article, the power spectrum density of the fractional amplitude fluctuation alpha was measured using Schottky and tunnel diodes in single-channel and correlation configuration, and the measurement methods were extended to the relative intensity noise (RIN) of optical beams.
Abstract: The close-in AM noise is often neglected, under the assumption that it is a minor problem as compared to phase noise. With the progress of technology and of experimental science, this assumption is no longer true. Yet, information in the literature is scarce or absent. This report describes the measurement of the AM noise of rf/microwave sources in terms of Salpha(f), i.e., the power spectrum density of the fractional amplitude fluctuation alpha. The proposed schemes make use of commercial power detectors based on Schottky and tunnel diodes, in single-channel and correlation configuration. There follow the analysis of the front-end amplifier at the detector output, the analysis of the methods for the measurement of the power-detector noise, and a digression about the calibration procedures. The measurement methods are extended to the relative intensity noise (RIN) of optical beams, and to the AM noise of the rf/microwave modulation in photonic systems. Some rf/microwave synthesizers and oscillators have been measured, using correlation and moderate averaging. As an example, the flicker noise of a low-noise quartz oscillator (Wenzel 501-04623E) is Salpha = 1.15E-13/f, which is equivalent to an Allan deviation of sigma_alpha = 4E-7. The measurement systems described exhibit the world-record lowest background noise.

26 citations


Posted Content
TL;DR: In this paper, the authors present a survey of the literature on noise in oscillators, focusing on the use of the Laplace transform to describe the oscillator and its phase noise.
Abstract: Time, and equivalently frequency, is the most precisely measured physical quantity. It is therefore inevitable that virtually all domains of engineering and physics need reference oscillators. The oscillator noise can be decomposed into amplitude noise and phase noise. The latter, far more important, affects timing, for it is related to precision and accuracy of measurements. The oscillator, inherently, turns the phase noise of the internal parts into frequency noise. This is a necessary consequence of the Barkhausen condition, which states that the loop gain must be of one, with zero phase, for stationary oscillation. There follows that oscillator phase noise, which is the integral of the frequency noise, diverges in the long run. This is the Leeson effect. The topics covered can be divided into three parts. Chapter 1 addresses language and general physical mechanisms. Chapter 2 aims at understanding the inside of commercial oscillators through the analysis of the specifications. Chapter 3 and 4 focus on the use of the Laplace transform to describe the oscillator and its phase noise. Since spring 2004, I had the opportunity to give some seminars on noise in oscillators at the Jet Propulsion Laboratory, at the IEEE Frequency Control Symposium, at the FEMTO-ST Laboratory, and at the Universite' Henri Poincare'. These seminars had the purpose to provide a TUTORIAL, as opposed to a report on advanced science, addressed to a variety of people including technicians, PhD students, and senior scientists. This booklet derives from these seminars, and from numerous discussions with colleagues.

25 citations


Posted ContentDOI
TL;DR: In this paper, the authors investigate the possibility of designing an inner tracker pixel detector whose data could be used for selecting events at the First Level Trigger at the Super-LHC, where the detector consists of two layers of 20x50x10 um3 pixels at very close radial proximity from each other.
Abstract: We report on preliminary design studies of a pixel detector for CMS at the Super-LHC. The goal of these studies was to investigate the possibility of designing an inner tracker pixel detector whose data could be used for selecting events at the First Level Trigger. The detector considered consists of two layers of 20x50x10 um3 pixels at very close radial proximity from each other so that coincidences of hits between the two layers amount to a track transverse momentum (pT) cut. This cut reduces the large amount of low-momentum data expected at SLHC while keeping the tracking efficiency very high for the high pT tracks. Preliminary results on the performance of such a detector are presented.

20 citations


ReportDOI
TL;DR: A recent workshop on SuperB in Italy as discussed by the authors focused on the machine and the detector and experimental issues, with a theoretical introduction of Marco Ciuchini and was structured in two working groups.
Abstract: This paper is based on the outcome of the activity that has taken place during the recent workshop on "SuperB in Italy" held in Frascati on November 11-12, 2005. The workshop was opened by a theoretical introduction of Marco Ciuchini and was structured in two working groups. One focused on the machine and the other on the detector and experimental issues. The present status on CP is mainly based on the results achieved by BaBar and Belle. Estabilishment of the indirect CP violation in B sector in 2001 and of the direct CP violation in 2004 thanks to the success of PEP-II and KEKB e+e- asymmetric B Factories operating at the center of mass energy corresponding to the mass of the Y(4s). With the two B Factories taking data, the Unitarity Triangle is now beginning to be overconstrained by improving the measurements of the sides and now also of the angles alpha, and gamma. We are also in presence of the very intriguing results about the measurements of sin(2 beta) in the time dependent analysis of decay channels via penguin loops, where b --> s sbar s and b --> s dbar d. Tau physics, in particular LFV search, as well as charm and ISR physics are important parts of the scientific program of a SuperB Factory. The physics case together with possible scenarios for the high luminosity SuperB Factory based on the concepts of the Linear Collider and the related experimental issues are discussed.

15 citations


Journal ArticleDOI
TL;DR: The architecture is based on parallel, independently running instrument handlers communicating with a main control program, which greatly simplifies their maintenance and expansion and an easy way of automation is achieved.
Abstract: In order to simplify and optimize the operation of our home made torque magnetometer we created a new software system. The architecture is based on parallel, independently running instrument handlers communicating with a main control program. All programs are designed as command driven state machines which greatly simplifies their maintenance and expansion. Moreover, as the main program may receive commands not only from the user interface, but also from other parallel running programs, an easy way of automation is achieved. A program working through a text file containing a sequence of commands and sending them to the main program suffices to automatically have the system conduct a complex set of measurements. In this paper we describe the system's architecture and its implementation in LabVIEW.

14 citations


Journal ArticleDOI
TL;DR: In this article, a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described.
Abstract: The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with gamma-rays indicate a high VUV light collection efficiency resulting in ~5.5 photoelectrons per 1 keV of deposited energy. The energy resolution (FWHM) is 18% and 22%, for 122 keV and 511 keV gamma-rays, respectively. An algorithm for the reconstruction of the scintillation coordinates in (x,y) plane was developed and tested. The position resolution is estimated to be 6.9 mm (sigma) for 122 keV gamma-rays.

Posted Content
TL;DR: In this paper, the authors show that the bias in the luminosity weighted centre of mass energy can be measured from the shift of the mean of the two distributions in the centre of energy.
Abstract: Wakefields in the main accelerator introduce a correlation between the z position of an electron in the bunch and its energy. Due to the disruption of the bunch in the interaction not all parts of the bunch contribute with the same weight to the luminosity. The combination of both effects introduces a bias in the luminosity weighted centre of mass energy. A detailed study can be found in [6]. For the TESLA design the effect is on average 150ppm with a spread of 30ppm and a maximum of 350ppm which is on the edge of being relevant. Figure 1 shows the centre of mass energy and the energy difference of colliding particles for TESLA. The histogram shows the real simulated distribution while the points show the artificial case where the energies have been ordered randomly. The bias can be seen from the shift of the mean of the two distributions in the centre of mass energy. The two distributions agree well in the energy difference. This means that the bias cannot be measured using the Bhabha acolinearity, which is proposed to measure the beam energy spectrum due to beamstrahlung [7]. If one does not want to rely completely on beam simulations methods using annihilation data are thus the only way to control such effects.

Journal ArticleDOI
TL;DR: In this paper, the authors describe five high-voltage (60 to 550V peak to peak), high-speed (1-300ns rise time; 1.3-300MHz bandwidth) linear amplifiers for driving capacitive or resistive loads such as electro-optic modulators.
Abstract: We describe five high-voltage (60 to 550V peak to peak), high-speed (1-300ns rise time; 1.3-300MHz bandwidth) linear amplifiers for driving capacitive or resistive loads such as electro-optic modulators. The amplifiers use bipolar transistors in various topologies. Two use electron tubes to overcome the speed limitations of high-voltage semiconductors. All amplifiers have been built. Measured performance data is given for each.

Journal ArticleDOI
TL;DR: In this paper, a sealed Ta crucible, easily fabricated from Ta tubing and sealed in a standard arc furnace, was used to perform differential thermal analysis on metallic alloys containing volatile elements.
Abstract: Differential thermal analysis on metallic alloys containing volatile elements can be highly problematic. Here we show how measurements can be performed in commercial, small-sample, equipment without modification. This is achieved by using a sealed Ta crucible, easily fabricated from Ta tubing and sealed in a standard arc furnace. The crucible performance is demonstrated by measurements on a mixture of Mg and MgB$_2$, after heating up to 1470$^{\circ}{\rm C}$. We also show data, measured on an alloy with composition Gd$_{40}$Mg$_{60}$, that clearly shows both the liquidus and a peritectic, and is consistent with published phase diagram data.

Journal ArticleDOI
TL;DR: In this article, the design of a low-noise amplifier intended as the input front-end for the measurement of the low-frequency components (below 10 Hz) of a 50 Ohm source was analyzed.
Abstract: This article analyzes the design of a low-noise amplifier intended as the input front-end for the measurement of the low-frequency components (below 10 Hz) of a 50 Ohm source. Low residual flicker is the main desired performance. This feature can only be appreciated if white noise is sufficiently low, and if an appropriate design ensures dc stability. An optimal solution is proposed, in which the low-noise and dc-stability features are achieved at a reasonable complexity. Gain is accurate to more than 100 kHz, which makes the amplifier an appealing external front-end for fast Fourier transform (FFT) analyzers.

Posted Content
TL;DR: In this paper, a simple and low-cost implementation of a fast electronic coincidence detector based on PECL logic with a TTL-compatible interface is presented, which has negligible dead time and the coincidence window is adjustable with a minimum width of 1 ns.
Abstract: We present a simple and low-cost implementation of a fast electronic coincidence detector based on PECL logic with a TTL-compatible interface The detector has negligible dead time and the coincidence window is adjustable with a minimum width of 1 ns Coincidence measurements of two independent sources of Bose-Einstein distributed photocounts are presented using different coincidence window widths

Posted Content
TL;DR: In this article, a simulation of the performance of a glass RPC detector at the single hadron level for different readout pad dimensions is presented, and the results are then used in a parametric form to obtain a preliminary estimate of the contribution of DHCAL to the reconstruction of the energy flow at the ILC detector.
Abstract: Glass RPC detectors are an attractive candidate for the active part of a highly granular digital hadron calorimeter (DHCAL) at the ILC. A numerical study, based on the GEANT3 simulation package, of the performance of such a calorimeter is presented in this work. A simplified model for the RPC response, tuned on real data, is implemented in the simulation. The reliability of the simulation is demonstrated by comparison to existing data collected with a large volume calorimeter prototype exposed to a pion beam in an energy range from 2 GeV to 10 GeV. In view of an optimization of the readout pitch, a detailed study of the energy and position resolution at the single hadron level for different read-out pad dimensions is presented. These results are then used in a parametric form to obtain a preliminary estimate of the contribution of DHCAL to the reconstruction of the energy flow at the ILC detector.

Journal ArticleDOI
TL;DR: The Q&A experiment as mentioned in this paper provides a feasible way of exploring the quantum vacuum through the detection of vacuum birefringence effect generated by QED loop diagram and detection of the polarization rotation effect produced by photon-interacting (pseudo-)scalar particles.
Abstract: The Q & A experiment, first proposed and started in 1994, provides a feasible way of exploring the quantum vacuum through the detection of vacuum birefringence effect generated by QED loop diagram and the detection of the polarization rotation effect generated by photon-interacting (pseudo-)scalar particles. Three main parts of the experiment are: (1) Optics System (including associated Electronic System) based on a suspended 3.5-m high finesse Fabry-Perot cavity, (2) Ellipsometer using ultra-high extinction-ratio polarizer and analyzer, and (3) Magnetic Field Modulation System for generating the birefringence and the polarization rotation effect. In 2002, the Q & A experiment achieved the Phase I sensitivity goal. During Phase II, we set (i) to improve the control system of the cavity mirrors for suppressing the relative motion noise, (ii) to enhance the birefringence signal by setting-up a 60-cm long 2.3 T transverse permanent magnet rotatable to 10 rev/s, (iii) to reduce geometrical noise by inserting a polarization-maintaining optical fiber (PM fiber) as a mode cleaner, and (iv) to use ultra-high extinction-ratio (10^{-9}) polarizer and analyzer for ellipsometry. Here we report on (iii) & (iv); specifically, we present the properties of the PM-fiber mode-cleaner, the transfer function of its suspension system, and the result of our measurement of high extinction-ratio polarizer and analyzer.

Posted Content
TL;DR: In this paper, the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e+e- International Linear Collider (ILC) is presented, which consists of a tungsten/silicon sandwich calorimeter with pad readout.
Abstract: This paper presents the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e+e- International Linear Collider (ILC) The detector consists of a tungsten/silicon sandwich calorimeter with pad readout The study was performed for Bhabha scattering events assuming a zero crossing angle for the beams

Posted Content
TL;DR: In this paper, the authors reported the operation of a self-oscillating maser using a laser diode as the optical pumping source, and the maser output power was maximized when the laser spectrum is spread by modulating its frequency through the variation of its injection current.
Abstract: We report the operation of a $^{87}$Rb maser in the self-oscillating mode, using a laser diode as the optical pumping source. The maser uses a TE$_{021}$ cavity surrounding a cell containing the atoms and 11 Torr of N$_{2}$ as the buffer gas. The optical pumping is accomplished by using a commercial laser diode frequency-locked on the linear absorption line of an external rubidium cell. The maser output power is maximized when the laser spectrum is spread by modulating its frequency through the variation of its injection current. The maser output power is also presented for various modulation waveforms and frequencies. We find that the spurious sidebands induced by the modulation can be minimized. Finally, the linear dependence between the laser and maser frequencies is shown. We find that the relative maser frequency pulling from the laser is about $4.6 \times 10^{-3}$.

Posted Content
TL;DR: The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A, parasitic with PEP-II operation as mentioned in this paper, which can be used to test prototype components of the Beam Delivery System and Interaction Region.
Abstract: The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.

Posted Content
Johannes Haller1
TL;DR: In this paper, the first-level trigger is implemented in custom hardware and has been designed to reduce the data rate from the initial bunch-crossing rate of 40 MHz to around 75 kHz.
Abstract: Due to the huge interaction rates and the tough experimental environment of pp collisions at a centre-of-mass energy sqrt(s)=14TeV and luminosities of up to 10^34 cm^-2 s^-1, one of the experimental challenges at the LHC is the triggering of interesting events. In the ATLAS experiment a three-level trigger system is foreseen for this purpose. The first-level trigger is implemented in custom hardware and has been designed to reduce the data rate from the initial bunch-crossing rate of 40 MHz to around 75 kHz. Its event selection is based on information from the calorimeters and dedicated muon detectors. This article gives an overview over the full first-level trigger system including the Calorimeter Trigger, the Muon Trigger and the Central Trigger Processor. In addition, recent results are reported that have been obtained from test-beam studies performed at CERN where the full first-level trigger chain was established successfully for the first time and used to trigger the read-out of up to nine ATLAS sub-detector systems.

Posted Content
TL;DR: In this paper, the authors studied the impact of charged track resolution on Higgs mass and production cross-section measurement in the process, assuming the International Linear Collider (ILC) is operated at 500 GeV center of mass energies (CME) with integrated luminosities of 500 $fb^{-1}$.
Abstract: We have studied the impact of charged track resolution on Higgs mass and production cross section measurement in the process $e^+e^- \to Z^0 H, Z^0 \to \ell^+\ell^-, H \to X$ for Higgs masses between 120 and 160 GeV, and on smuon mass measurement using smuon pair production for three different mass pairs, assuming the International Linear Collider(ILC) is operated at 500 GeV center of mass energies (CME) with integrated luminosities of 500 $fb^{-1}$. The effect of initial state radiation (ISR), beamstrahlung and beam energy spread on Higgs and smuon mass measurement are also estimated. Using fast Monte Carlo simulations of the 2001 North American baseline detector designs (LD and SD), we find that the ISR and beamstrahlung have significant impact on Higgs and smuon mass measurement; Charged track momentum resolution affect Higgs mass significantly with better track performance yielding better Higgs mass resolution and precision for the track momentum resolution improvement up to a factor of about 5; Track momentum resolution has little effect on the measurement precision of the Higgsstrahlung cross section, the branching ratio of $H \to C\bar{C}$, the smuon and neutralino masses; Beam energy spread better than about 0.2% has little effect on Higgs, smuon and neutralino masses; The SD detector provides a more accurate measurement than the LD of the Higgs mass.

Posted Content
TL;DR: In this article, the authors proposed a bottomhole pressure calculation procedure from fluid level measurements, which allows to calculate BHP without shutting the well, which is common for fluid level casinghead pressure measurements.
Abstract: The ability to monitore bottomhole flowing pressure in pumping oil wells provides important information regarding both reservoir and artificial lift performance. Converting surface pressure measurements to bottomhole is currently accomplished by locating the fluid level in the annulus using a sonic device and then applying a correlation to estimate the density of the gas-cut liquid column above the perforations. This work proposes a flowing bottomhole pressure calculation procedure from fluid level measurements. The model is developed from experimental work and from theoretical arguments. The calculation procedure developed allows to calculate BHP without shutting the well, which is common for fluid level casinghead pressure measurements. Also this method allows to take into account real geometry of the The comparison of the calculated and measured pump intake pressure shows good accuracy of a technique. It allows to draw a conclusion for an opportunity to use this method in practice.

Posted Content
TL;DR: In this article, the authors applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC.
Abstract: The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.

Proceedings ArticleDOI
TL;DR: In this article, the feasibility of a microwave power standard based on the electromagnetic interaction with cold atoms was demonstrated, under the effect of the radiation, the internal state populations will undergo a Rabi oscillation and the measurement of its frequency will allow the determination of the electromagnetic field strength.
Abstract: We demonstrate the feasibility of a novel microwave power standard based on the electromagnetic interaction with cold atoms. Under the effect of the radiation, the internal state populations will undergo a Rabi oscillation. The measurement of its frequency will allow the determination of the electromagnetic field strength.

Posted Content
TL;DR: In this paper, a new particle identification device for Jlab 12 GeV program is proposed based on the measurement of time information obtained by means of a new photon detector and time measuring concept.
Abstract: A new particle identification device for Jlab 12 GeV program is proposed. It is based on the measurement of time information obtained by means of a new photon detector and time measuring concept. The expected time measurement precision for the Cherenkov time-of-flight detector is about or less than 10 picosecond for Cherenkov radiators with lengths less than 50 cm.

Proceedings ArticleDOI
TL;DR: In this paper, the effect of radiation damage after the exposure of a CCD detector to a realistic radiation dose, which is expected in the environment of detector operation at a future linear e+e-collider, is investigated.
Abstract: The Linear Collider Flavour Identification (LCFI) collaboration studies CCD detectors for quark flavour identification in the framework of a future linear e+e- collider. The flavour identification is based on precision reconstruction of charged tracks very close to the interaction point. Therefore, this detector will be exposed to a high level of radiation and thus an important aspect of the vertex detector development are radiation hardness studies. Results of detailed simulations of the charged transport properties of a CCD prototype chip are reported and compared with initial measurements. The simulation program allows to study the effect of radiation damage after the exposure of the detector to a realistic radiation dose, which is expected in the environment of detector operation at a future LC.

Proceedings ArticleDOI
TL;DR: In this paper, a 1D and 2D UV sealed photosensitive gaseous detectors with resistive electrodes were used for spectroscopy, hyperspectroscopy and flame detection.
Abstract: Hyperspectroscopy is a new method of surface image taking, providing simultaneously high position and spectral resolutions which allow one to make some conclusions about chemical compositions of the surfaces. We are now studying applications of the hyperspctroscopic technique to be used for medicine. This may allow one to develop early diagnostics of some illnesses, as for example, skin cancer. For image taking advanced MCPs are currently used, sensitive in the spectral interval of 450-850 nm. One of the aims of this work is to extend the hyperspectrocpic method to the UV region of spectra: 185-280 nm. For this we have developed and successfully tested innovative 1D and 2D UV sealed photosensitive gaseous detectors with resistive electrodes. These detectors are superior MCPs due to the very low rate of noise pulses and thus due to the high signal to noise ratio. Other important features of these detectors are that they have excellent position resolutions - 30 micron in digital form, are vibration stable and are spark protected. The first results from the application of these detectors for spectroscopy, hyperspectroscopy and the flame detection are presented.

Posted Content
TL;DR: In this article, an approach is proposed which allows evaluating the influence of the PWO crystals properties on the statistical term in the energy resolution of the electromagnetic calorimeter and gives important information about the nature of the radiation damage mechanism in scintillation crystals.
Abstract: Kinetics of radiation damage of the PWO crystals under irradiation and recovery were studied. Crystals were irradiated with dose corresponding to average one expected in the electromagnetic calorimeter (working dose irradiation). Radiation damage and recovery were monitored through measurements of PWO optical transmission. An approach is proposed which allows evaluating the influence of the PWO crystals properties on the statistical term in the energy resolution of the electromagnetic calorimeter. The analysis also gives important information about the nature of the radiation damage mechanism in scintillation crystals. The method was used during development of technology of the mass production of radiation hard crystals and during development of methods for crystals certification