scispace - formally typeset
Proceedings ArticleDOI

Initial study on pulse wave velocity acquired from one hand using two synchronized wireless reflectance pulse oximeters

Kejia Li, +1 more
- Vol. 2011, pp 6907-6910
Reads0
Chats0
TLDR
This paper presents an approach to measure PWV using two synchronized, wireless pulse oximeters placed on the wrist and fingertip of the same hand, and shows that PWV values for inflection points are larger than those calculated at waveform feet.
Abstract
Pulse wave velocity (PWV) has garnered attention as a means to estimate vessel elasticity. This paper presents an approach to measure PWV using two synchronized, wireless pulse oximeters placed on the wrist and fingertip of the same hand. A MATLAB interface acquires and time-aligns these incoming photoplethysmograms (PPGs), and then it calculates PWVs using time differences at three waveform features: the foot, inflection point, and peak of the rising slope in each PPG. Consistent with expectations, PWV values for inflection points are larger than those calculated at waveform feet, since PWV is known to increase with increased intra-arterial pressure. However, the presence of pulse wave reflections complicates the interpretation of PWVs calculated from the PPG peaks since the reflected components impose a varying time delay on the related peaks.

read more

Citations
More filters
Journal ArticleDOI

A Wireless Reflectance Pulse Oximeter With Digital Baseline Control for Unfiltered Photoplethysmograms

TL;DR: This paper presents a small, low-cost pulse oximeter design appropriate for wearable and surface-based applications that also produces quality, unfiltered photo-plethysmograms (PPGs) ideal for emerging diagnostic algorithms.
Journal ArticleDOI

Signal Processing of Multimodal Mobile Lifelogging Data Towards Detecting Stress in Real-World Driving

TL;DR: This work describes a set of algorithms designed to process multiple streams of lifelogging data for stress detection in the context of real world driving and results were positive and ensemble classification models provided a maximum accuracy for binary detection of stress in the real-world.
Proceedings ArticleDOI

Magnetic plethysmograph transducers for local blood pulse wave velocity measurement

TL;DR: The developed transducers provide a reliable, easy modality for detecting pulse waveform on superficial arteries and could potentially be utilized for cuffless, continuous evaluation of BP at various superficial arterial sites.
Proceedings ArticleDOI

A novel method for pulse transit time estimation using wrist bio-impedance sensing based on a regression model

TL;DR: This work explores the measurement of PTT using two bio-impedance (Bio-Z) sensors placed on the wrist 7.5 cm apart such that they can be integrated into a wrist watch.
Proceedings ArticleDOI

Exploration and validation of alternate sensing methods for wearable continuous pulse transit time measurement using optical and bioimpedance modalities

TL;DR: Results indicate that the PTT calculated from the Bio-Z and PPG sensors placed at a close distance correlates well with the more established PTT measurement using the ECG in conjunction with PPG, with correlation coefficient as high as 0.92.
References
More filters
Journal ArticleDOI

Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.

TL;DR: This article examines the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis.
Journal ArticleDOI

Utility of the photoplethysmogram in circulatory monitoring.

TL;DR: Overall, the photoplethysmogram provides a wealth of circulatory information, but its complex etiology may be a limitation in some novel applications.
Journal ArticleDOI

Predicting Arterial Stiffness From the Digital Volume Pulse Waveform

TL;DR: It is concluded that support vector machine-based classification and regression techniques provide effective prediction of arterial stiffness from the simple measurement of the digital volume pulse.
Journal ArticleDOI

Chest Pulse-Wave Velocity: A Novel Approach to Assess Arterial Stiffness

TL;DR: A new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor is presented, relying on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum.
Proceedings ArticleDOI

Measurement of local pulse wave velocity in arteriosclerosis by ultrasonic Doppler method

TL;DR: Local PWV at a point several millimeters along the aorta is precisely obtained by dividing distance between these points by resultant transit delay time, and will prove useful, especially for noninvasive diagnosis of early stage arteriosclerosis.