scispace - formally typeset
Journal ArticleDOI

Peak shifts in gas proportional scintillation counters

Reads0
Chats0
TLDR
In this paper, a xenon gas proportional scintillation counter working in or very near the ionization chamber region was tested under high X-ray fluxes from a 55 Fe source.
About
This article is published in Nuclear Instruments and Methods.The article was published on 1973-09-01. It has received 13 citations till now. The article focuses on the topics: Ionization chamber & Scintillation counter.

read more

Citations
More filters
Journal ArticleDOI

Detection of soft X-rays with a xenon proportional scintillation counter

TL;DR: In this article, soft X-rays were detected with a xenon proportional scintillation counter; for example, full widths at half maximum of 100 eV and 140 eV were obtained for the carbon and oxygen X-ray, respectively.
Journal ArticleDOI

The Scintillating Drift Chamber: A New Tool for High Accuracy, Very High Rate Particle Localization

TL;DR: In this article, a photomultiplier detects the photons emitted by the electrons drifting in a strong electric field in a short gap at the end of the drift space, where the absence of space charge leads to considerable high-rate capabilities; at 2x106/s mm2 no change of characteristics is observed.
Journal ArticleDOI

New Near-Infrared and Ultraviolet Gas-Proportional Scintillation Counters

TL;DR: In this article, a gas-proportional scintillation counters have been performed using a large alpha source, reasonable spectral resolution (< 25-k), and including the strong near-infrared transitions in noble gases excluded in all previous studies.
Journal ArticleDOI

The Energy Resolution and Window Area Capabilities of the Gas Proportional Scintillation Counter

TL;DR: In this paper, the relative efficiencies of tetraphenylbutadiene, p-terphenyl, diphenyl-stilbene, sodium salicylate and p-quaterphenyl were measured.
Journal ArticleDOI

A Parallel Plate Imaging Proportional Counter with High Background Rejection Capability

TL;DR: In this article, the results of studies of the scintillation produced by avalanches in a parallel plate proportional counter were presented, and it was shown that background rejection of greater than 90% may be achieved by risetime discrimination using the light pulse.
References
More filters
Journal ArticleDOI

Space Charge Effects in Proportional Counters

TL;DR: In this paper, a quantitative theory for the mean shift of the energy peak created by mono-energetic x rays was developed and confirmed experimentally, and a quantitative model for the effect of positive ions on the position and breadth of energy peak was proposed.
Journal ArticleDOI

Improved resolution for low energies with gas proportional scintillation counters.

TL;DR: In this article, the relative variance of the pulses from the gas proportional scintillation counter was measured for a full width half maximum of 500 eV for 59 keV and the possibility of using the counter for fast coincidence work is considered.
Journal ArticleDOI

New Concepts in Nuclear Pulse Amplifier Design

TL;DR: In this paper, a nuclear pulse amplifier with a linear lumped-element network was designed to approximate desirable overall transfer functions, and it was evaluated for overload recovery, crossover walk, pile-up distortion, common mode rejection, and noise-to-signal ratio.
Journal ArticleDOI

Gain stability in high-current photomultipliers at high variable counting rates

TL;DR: In this article, the energy resolution of 56AVP photomultiplier tube was found to deteriorate at high counting rates and this gain shift was nearly eliminated by keeping the voltages stabilized for the last two stages of the photomULTiplier chain.
Journal ArticleDOI

Improved energy resolution with X ray gas detectors

TL;DR: In this paper, the detection of the light pulses from a xenon counter gives a resolution of 11.2% for 5.9 keV and this value can be further improved.
Related Papers (5)