scispace - formally typeset
Open AccessJournal ArticleDOI

The Liquid Membranes of the Thiocyanate Ion-Sensitive Electrode

Nobuhiko Ishibashi, +1 more
- 01 Aug 1973 - 
- Vol. 46, Iss: 8, pp 2454-2456
TLDR
In this article, a crystal violet or tetraphenylarsonium cation was used as an ion exchange-site in the liquid nitrobenzene membrane, which exhibits an ideal Nernstian response to the thiocyanate ion down to 10−5 M.
Abstract
Ion-selective electrode membranes responsive to the thiocyanate ion were prepared by using ion-association extraction systems. A crystal violet or tetraphenylarsonium cation was used as an ion exchange-site in the liquid nitrobenzene membrane. The liquid membrane electrode exhibits an ideal Nernstian response to the thiocyanate ion down to 10−5 M. The selectivity of the liquid membrane largely depends on the extractability of the diverse anion into nitrobenzene. The order of the selectivity coefficients, Kj, is as follows:ClO_4^->IO_4^->SCN^->I^->ClO_3^->NO_3^->Br^->BrO_3^->Cl^-High selectivities for thiocyanate over SO42−, H2PO4−, Cl−, BrO3−, and Br were observed. The membrane potential is independent of the pH variation in the region from pH 2 to 12.

read more

Citations
More filters
Journal ArticleDOI

Ion selective electrodes, potentiometry, and potentiometric titrations.

TL;DR: A selection of notable people and works related to Chromatogr, or “chim”, dating from 1970 to 1971, as well as specific cases up to and including 1971:.
Journal ArticleDOI

Theory and applications of ion-selective electrodes part II

TL;DR: A review on ion-selective electrodes is arranged in the same way as Part I in this paper, where substantial growth of the whole subject is emphasized, and progress in theory centres on the mechanism of the response of both solid and liquid membrane systems.
Journal ArticleDOI

Mn(III)—porphyrin-based thiocyanate-selective membrane electrodes: Characterization and application in flow injection determination of thiocyanate in saliva

TL;DR: In this article, a thiocyanate-selective solvent-polymeric membrane electrode was proposed for detection of thioxyanate in 22 human saliva samples with good correlation to a classical colorimetric method (r = 0.981).
Journal ArticleDOI

Ion-selective Electrodes Sensitive to Some Organic Compounds Used as Drugs

TL;DR: In this article, drug ion-selective electrodes with a liquid membrane have been developed which are sensitive to methacholine, neostigmine, N-1-methyl nicotinamide, diphenhydramine, vitamin B1 and vitamin B6.
Journal ArticleDOI

Prediction of selectivity coefficients of univalent anions for anion-selective electrode using support vector machine

TL;DR: In this article, support vector machine (SVM) was applied for the prediction of selectivity coefficients of anion-selective electrode for some univalent anions, which revealed the reliability of this model.
References
More filters
Journal ArticleDOI

Calcium-selective electrode with liquid ion exchanger.

James W. Ross
- 09 Jun 1967 - 
TL;DR: A simple calcium-selective electrode has been developed which is capable of measuring calcium ion activity in the presence of many common interfering ions.
Journal ArticleDOI

The Steady-State Properties of an Ion Exchange Membrane with Mobile Sites

TL;DR: A study of the properties of the steady states of a system composed of two solutions separated by an ion exchange membrane having mobile sites finds that the expressions of certain quantities, such as the difference of electric potential between the two solutions for zero current or the ratio of the fluxes of the counterions as functions of the external parameters of the system, are the same for both types of membranes.
Journal ArticleDOI

The distribution of salts of large cations between water and organic solvents: Part II. Factors affecting the magnitude of the distribution ratio

TL;DR: In this article, the results of the extraction of fourteen different quaternary cations with nineteen different anions into four different solvents were discussed in terms of the effects of the cation, the anion and the organic solvent on the distribution ratio.
Journal ArticleDOI

Perchlorate Ion-Selective Electrodes with the Liquid Membranes of the O-Phenanthroline Chelate or its Related Compounds

TL;DR: In this paper, the metal chelates of o-phenanthroline, a, a′-dipyridyl or bathophenanthroine were used as the ion exchanger in the liquid membrane of the perchlorate ion-selective electrode.
Journal ArticleDOI

Liquid Ion Exchanger Membrane Electrode Sensitive to Perrhenate and Thiocyanate; U-Shaped Potentiometric Titration Curves

TL;DR: The Orion perchlorate ion activity electrode as mentioned in this paper is sensitive to perrhenate and thiocyanate activities and the response is Nernstian over several orders of magnitude.
Related Papers (5)