scispace - formally typeset
Journal ArticleDOI

Timing properties of scintillation counters

B. Bengtson, +1 more
- 01 May 1970 - 
- Vol. 81, Iss: 1, pp 109-120
TLDR
In this article, the authors studied the shape of C / R curves and in particular the optimum of C/R values depend strongly on the type and dimension of scintillators.
About
This article is published in Nuclear Instruments and Methods.The article was published on 1970-05-01. It has received 108 citations till now. The article focuses on the topics: Scintillation counter.

read more

Citations
More filters
Journal ArticleDOI

Barium fluoride — Inorganic scintillator for subnanosecond timing

TL;DR: In this article, a BaF 2 crystal coupled to a XP 2020 Q photomultiplier with quartz window was used as a scintillator for light pulse shape investigation.
Journal ArticleDOI

Development of organic scintillators

TL;DR: The development of organic scintillators is reviewed with emphasis on work that has been reported since 1964 as mentioned in this paper, and the scintillation process is discussed, including response energy dependence, energy resolution, timing characteristics, pulse shape discrimination and anisotropy.
Journal ArticleDOI

Scintillation Properties of LuAG:Ce, YAG:Ce and LYSO:Ce Crystals for Gamma-Ray Detection

TL;DR: In this paper, the scintillation properties of LuAG:Ce and YAG-Ce crystals were compared with LYSO:ce crystal under?-ray excitation.
Journal ArticleDOI

The lower bound on the timing resolution of scintillation detectors

TL;DR: In this work, the Cramér-Rao lower bound on the timing resolution of a scintillation detector, based on the information contained in the full set of registered photons, is calculated and appears to be in good agreement with trends observed in the literature.
Journal ArticleDOI

Properties of the YAP : Ce scintillator

TL;DR: In this article, a 10 × 10 × 5 mm 3 YAB crystal coupled to the XP2020Q photomultiplier was studied, which exhibited an energy resolution of 5.7% for 662 keV γ-rays fron a 137 Cs source.
References
More filters
Journal ArticleDOI

Design of the constant fraction of pulse height trigger for optimum time resolution.

TL;DR: In this paper, the constant fraction of pulse height trigger has been shown to provide the optimum time resolution with a scintillator-photomultiplier system, and a circuit suitable for general use is presented.
Journal ArticleDOI

Time Resolution of Photomultiplier Systems

TL;DR: In this paper, the ability of a photomultiplier system to resolve time differences is presented in graphic form and the results are presented in parametric form and hence may be applied to a wide variety of scintillator•photomULTiplier combinations, provided the system is reasonably approximated by the model used in this work.
Journal ArticleDOI

A constant fraction of pulse height trigger for optimum time resolution

TL;DR: In this paper, a fast discriminator has been designed which triggers at a constant fraction of the input signal amplitude, when operated by the anode current pulse from a photomultiplier tube, making it possible to obtain optimum timing over a 100 : 1 dynamic range.
Journal ArticleDOI

A survey of the latest developments in delayed coincidence measurements

TL;DR: A survey of the techniques for measurement of sub-milli-mircosecond nuclear lifetimes by the delayed coincidence method is presented in this paper, where the time response and limitations of photomultiplier, plastic scintillator and associated electronics are discussed.
Journal ArticleDOI

Study of High Speed Photomultiplier Systems

TL;DR: In this article, a model for the response of a photomultiplier was presented, which was obtained from direct measurements on a 56 AVP photomULTiplier and used to predict quantities such as distribution of triggering times, pulse shapes, etc.
Related Papers (5)