Details on surgical steps and tips for enhancing outcomes for an open conjunctiva technique for the implantation of the Xen Gel Stent are provided, as well as reasoning as to when this approach should be used.
Abstract
The Xen Gel Stent lowers intraocular pressure by shunting aqueous humor to the subconjunctival space. While published studies include both open conjunctiva and closed conjunctiva approaches, most publications feature a closed conjunctiva, ab interno approach. While this approach is widely used, other approaches may be preferred for some patients. This paper provides details on surgical steps and tips for enhancing outcomes for an open conjunctiva technique for the implantation of the Xen Gel Stent, as well as reasoning as to when this approach should be used.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement.

TL;DR: In this paper, the safety and efficacy of two different techniques for implantation of the XEN Gel Stent, a minimally invasive surgical device for the treatment of refractory glaucoma, were compared.
Journal ArticleDOI

Microinvasive Glaucoma Surgery: An Evidence-Based Review.

TL;DR: In this paper, a review focusing on peer-reviewed evidence for Trabectome, iStent inject, Kahook Dual Blade, XEN® Gel Stent, and Hydrus® is presented.
Journal ArticleDOI

XEN Glaucoma Implant for the Management of Operated Uncontrolled Glaucoma: Results and Complications during a Long-Term Follow-Up.

TL;DR: In this article, the surgical and refractive outcomes of XEN glaucoma implant (Allergan, an Abbvie company, Irvine, CA, USA), a minimally invasive surgical device for the treatment of operated uncontrolled glauca, were retrospectively investigated.
Journal ArticleDOI

XEN Glaucoma Implant for the Management of Glaucoma in Naïve Patients versus Patients with Previous Glaucoma Surgery

TL;DR: In this article, the surgical and refractive outcomes of a XEN Gel Implant (Allergan, Abbvie Company, Irvine, CA, USA) in naive patients versus those with previous glaucoma surgery were analyzed.
References
More filters
Journal ArticleDOI

Wound healing in glaucoma filtering surgery.

TL;DR: The process of wound healing after glaucoma filtering surgery is summarized and the scientific rationale of several surgical and pharmacologic techniques introduced to enhance success in eyes with poor surgical prognoses is elucidated.
Journal ArticleDOI

Performance and Safety of a New Ab Interno Gelatin Stent in Refractory Glaucoma at 12 Months.

TL;DR: The gelatin stent reduced IOP and medication use without raising unexpected safety concerns, offering a minimally invasive surgical option for refractory glaucoma patients.
Journal ArticleDOI

Minimally invasive combined glaucoma and cataract surgery: clinical results of the smallest ab interno gel stent

TL;DR: This study demonstrated that the smaller diameter XEN 45 gel implant is statistically effective in reducing intraocular pressure and medications in glaucoma patients with a low rate of complications.
Journal ArticleDOI

Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results.

TL;DR: The XEN gel implant as a standalone procedure or combined with cataract surgery demonstrated safe and sustained IOP reduction after 1 year, and in all, 37% of patients required needling intervention.
Related Papers (3)