scispace - formally typeset
Search or ask a question

Showing papers by "Maurizio Galderisi published in 2005"


Journal ArticleDOI
TL;DR: Prevalence of concentric LV hypertrophy is suggested to be defined by coexistence of high LV mass with age-normalized RWTm >0.41 or RWTp <0.40, as well as in hypertensive subjects.
Abstract: There might be limitations in identifying concentric left ventricular (LV) geometry by ratio of diastolic posterior wall thickness (WT(p)) to cavity radius, defined as relative wall thickness (RWT(p)). This study has been designed to evaluate age effects on RWT(p). WT(p), mean of septal thickness and WT(p) (WT(m)), and cavity radius were cross-sectionally evaluated in 766 1- to 85-year-old, normotensive, nonobese subjects and 331 hypertensive Italians (used as a test series). RWT(p) > or =0.43 defined "traditional" concentric LV geometry. The ratios WT(m)/radius (RWT(m)) and RWT(p) increased by 0.005 and 0.006 per year of age in the age stratum up to 17 years and by 0.002 in the older age stratum (18 years or older; all P 0.41 or RWT(p) >0.40. Further studies are required to establish prognostic implications of our findings.

196 citations


Journal ArticleDOI
TL;DR: The therapy of LV DD and HF is not well established but ACE-inhibitors, angiotensin inhibitors, aldosterone antagonists and β-blockers show potential beneficial effect on diastolic properties.
Abstract: Left ventricular (LV) diastolic dysfunction (DD) and diastolic heart failure (HF), that is symptomatic DD, are due to alterations of myocardial diastolic properties. These alterations involve relaxation and/or filling and/or distensibility. Arterial hypertension associated to LV concentric remodelling is the main determinant of DD but several other cardiac diseases, including myocardial ischemia, and extra-cardiac pathologies involving the heart are other possible causes. In the majority of the studies, isolated diastolic HF has been made equal to HF with preserved systolic function (= normal ejection fraction) but the true definition of this condition needs a quantitative estimation of LV diastolic properties. According to the position of the European Society of Cardiology and subsequent research refinements the use of Doppler echocardiography (transmitral inflow and pulmonary venous flow) and the new ultrasound tools has to be encouraged for diagnosis of DD. In relation to uncertain definitions, both prevalence and prognosis of diastolic heart failure are very variable. Despite an apparent lower death rate in comparison with LV systolic HF, long-term follow-up (more than 5 years) show similar mortality between the two kinds of HF. Recent studies performed by Doppler diastolic indexes have identified the prognostic power of both transmitral E/A ratio 1.5 (restrictive patterns). The therapy of LV DD and HF is not well established but ACE-inhibitors, angiotensin inhibitors, aldosterone antagonists and β-blockers show potential beneficial effect on diastolic properties. Several trials, completed or ongoing, have been planned to treat DD and diastolic HF.

140 citations


Journal ArticleDOI
TL;DR: Transthoracic Doppler echocardiographic-derived coronary flow reserve is an useful hemodynamic index to assess dysfunction of coronary microcirculation and is equally non invasive but cheaper, very accessible and prone to a reliable exploration of coronarymicrovascular territories.
Abstract: Transthoracic Doppler echocardiographic-derived coronary flow reserve is an useful hemodynamic index to assess dysfunction of coronary microcirculation. Isolated coronary microvascular abnormalities are overt by reduced coronary flow reserve despite normal epicardial coronary arteries. These abnormalities may occur in several diseases (arterial hypertension, diabetes mellitus, hypercholesterolemia, syndrome X, aortic valve disease, hypertrophic cardiomyopathy and idiopathic dilated cardiomyopathy). The prognostic role of impaired microvascular coronary flow reserve has been shown unfavourable especially in hypertrophic or idiopathic dilated cardiomyopathies. Coronary flow reserve reduction may be reversible, for instance after regression of left ventricular hypertrophy subsequent to valve replacement in patients with aortic stenosis, after anti-hypertensive treatment or using cholesterol lowering drugs. Coronary flow reserve may increase by 30% or more after pharmacological therapy and achieve normal level >3.0. In contrast to other non invasive tools as positron emission tomography, very expensive and associated with radiation exposure, transthoracic Doppler-derived coronary flow reserve is equally non invasive but cheaper, very accessible and prone to a reliable exploration of coronary microvascular territories, otherwise not detectable by invasive coronary angiography, able to visualize only large epicardial arteries.

90 citations


Journal ArticleDOI
TL;DR: The hypothesis is that in hypertension, pulse pressure may be considered as a marker of preclinical cardiovascular disease, similar to LV mass and PP/SV, rather than a cardiovascular risk factor.
Abstract: This study tests the hypothesis that high brachial pulse pressure might constitute preclinical cardiovascular disease, rather than a risk factor. We studied 1250 subjects (472 nonobese normotensive [ 63 mm Hg, and peripheral resistance high when >90th percentile of normal distribution. Among hypertensive subjects, 34% had high resistance; among them, 33% had high brachial pulse pressure, as opposed to 147 of 516 patients (28.5%) with normal resistance (P=not significant). After adjusting for age, sex, race, body mass index, heart rate, and center, left ventricular (LV) internal dimension and mass were lower with high resistance, and higher when brachial pulse pressure was high. PP/SV was 36% higher with high resistance than with normal resistance, and higher when brachial pulse pressure was high (all P<0.0001). Factorial analysis demonstrated that associations of high brachial pulse pressure with both higher PP/SV and LV mass were independent of other pressure components. Thus, because of these associations, our hypothesis is that in hypertension, pulse pressure may be considered as a marker of preclinical cardiovascular disease, similar to LV mass and PP/SV, rather than a cardiovascular risk factor.

65 citations


Journal ArticleDOI
TL;DR: The combination of DTI indices of the mitral annulus and mitral inflow velocities provides reliable parameters to predict LV filling pressure in patients with MR both in patientswith LV EF > 50% and < 50%.

39 citations


Journal ArticleDOI
TL;DR: HHD may generally allow a reliable cardiologic basic evaluation of outpatient or subjects admitted to non-cardiologic sections, more specifically in particular subgroups of patients, with a gain in terms of time, shortening patient waiting lists and reducing healthy costs.
Abstract: The ultrasonic industry has recently produced echocardiographic Hand Held Devices (miniaturized, compact and battery-equipped echocardiographic systems). Their potential usefulness has been successfully assessed in a wide range of clinical conditions. The aim of the study was to verify if the routine use of a basic model of echocardiographic Hand Held Device (HHD) could be an important diagnostic tool during outpatient cardiologic consulting or in non-cardiologic hospital sections. 87 consecutive patients were included in this study; they underwent routine physical examination, resting ECG and echocardiographic evaluation using a basic model of HHD performed by trained echocardiographists; the cardiologist, whenever possible, formulated a diagnosis. The percentage of subjects in whom the findings were judged reasonably adequate for final diagnostic and therapeutic conclusions was used to quantify the "conclusiveness" of HHD evaluation. Successively, all patients underwent a second echocardiographic evaluation, by an examiner with similar echocardiographic experience, performed using a Standard Echo Device (SED). The agreement between the first and the second echocardiographic exam was also assessed. Mean examination time was 6.7 ± 1.5 min. using HHD vs. 13.6 ± 2.4 min. using SED. The echocardiographic examination performed using HHD was considered satisfactory in 74/87 patients (85.1% conclusiveness). Among the 74 patients for whom the examination was conclusive, the diagnosis was concordant with that obtained with the SED examination in 62 cases (83.8% agreement). HHD may generally allow a reliable cardiologic basic evaluation of outpatient or subjects admitted to non-cardiologic sections, more specifically in particular subgroups of patients, with a gain in terms of time, shortening patient waiting lists and reducing healthy costs.

30 citations


Journal Article
TL;DR: Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening.
Abstract: Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

18 citations


Journal ArticleDOI
TL;DR: A 36-year-old male patient receiving long-term oral treatment with acenocoumarol, a synthetic coumarin anticoagulant, who experienced an increase in international normalized ratio (INR) and a hematoma in the left leg approximately 45 days after the initiation of treatment with rosuvastatin is described.

13 citations


Journal ArticleDOI
TL;DR: It is indicated that short-term hyperglycemia does not affect the vasodilatory response of coronary microcirculation in healthy subjects.
Abstract: Objective: There is some evidence that acute hyperglycemia (H) may cause vascular dysfunction in normal subjects. This study investigates whether acute, short-term H affects coronary vasodilatory function in healthy subjects. Design: Diastolic peak flow velocity in the left anterior descending coronary artery was measured at rest and after dipyridamole (0.56 mg/kg over 4 min) using transthoracic color Doppler echocardiography in 13 healthy men. Coronary flow reserve (CFR) was defined as the ratio of dipyridamole-induced coronary peak diastolic to resting peak diastolic flow velocity. CFR was measured both in euglycemia (E) and after 3 h H (∼14 mmol/liter) by a variable infusion of glucose and octreotide (0.4 mg/h) to prevent increase in insulin concentration. Results: Fasting plasma glucose increased to 14.3 ± 0.33 mmol/liter during the study and maintained variability within less than 10%. Plasma insulin remained nearly stable during H. Resting diastolic flow velocity was 18.5 ± 0.6 cm/sec in E and incre...

11 citations


Journal Article
TL;DR: Doppler echocardiographic evaluation of MAGs is a reliable, noninvasive tool to assess MAG patency and functional status of the vessel.

8 citations



Journal Article
TL;DR: Preliminary experiences show the possibility of improving and anticipating the diagnosis of several cardiac diseases but also the need to plan specific ultrasound training to avoid inappropriate use of HHE.
Abstract: In the last years the industry has created echocardiographic portable machines of reduced size, available for a growing number of operators. After the first experiences of the '70s, hand-held echocardiography (HHE) is earned interesting commercial positions. The transportability of these machines allows to perform examinations outside the echo-lab and provides diagnostic information in heterogeneous locations such as intensive care unit, emergency room and outpatient structures, at the bedside and even in ambulance. HHE can be useful for detection of several pathologies including aortic aneurysms and left ventricular hypertrophy, regional wall motion abnormalities, pericardial and pleural effusion. To date, four main kinds of HHE can be distinguished: a first, high-cost variety, including miniaturized machines, equipped with instrumentations of standard echocardiography and even new softwares for tissue Doppler and myocardial contrast echocardiography; a second kind of machines of high level but not miniaturized; a third (intermediate level and low cost), and a fourth one (basic level and very low cost), including "cardioscopes" corresponding to the ultrasound stethoscope, able to complete efficaciously the clinical examination. The introduction of HHE opens controversy about its diagnostic accuracy, the opportunity to establish the clinical scenario where it should be utilized and the identification of the potential users and the needed competence level. Preliminary experiences show the possibility of improving and anticipating the diagnosis of several cardiac diseases but also the need to plan specific ultrasound training to avoid inappropriate use of HHE.