scispace - formally typeset
Y

Yu-Hang Ji

Researcher at Chinese Academy of Sciences

Publications -  5
Citations -  36

Yu-Hang Ji is an academic researcher from Chinese Academy of Sciences. The author has contributed to research in topics: Atom interferometer & Observational error. The author has an hindex of 2, co-authored 5 publications receiving 15 citations.

Papers
More filters
Posted ContentDOI

Joint mass-and-energy test of the equivalence principle at the 10 − 10 level using atoms with specified mass and internal energy

TL;DR: In this article, the authors used rubidium atoms with specified mass and internal energy to carry out a joint mass-energy test of the equivalence principle (EP), and they used the extended 4WDR to select atoms with a certain mass and angular momentum state, and form a dual-species atom interferometer.
Journal ArticleDOI

Laser frequency shift up to 5 GHz with a high-efficiency 12-pass 350-MHz acousto-optic modulator

TL;DR: Combining the ±1st order diffraction, laser signals with up to 10 GHz frequency difference can be obtained, which fulfill most frequency shift requirements of laser cooling and coherent manipulation experiments with alkali metal atoms.
Journal ArticleDOI

Suppression of Coriolis error in weak equivalence principle test using ^[85]Rb-^[87]Rb dual-species atom interferometer

TL;DR: In this paper, the problem of Coriolis error in weak equivalence principle (WEP) test using atom interferometer has been studied theoretically and experimentally, and the measurement errors of Eotvos coefficient (eta) in WEP test related to experimental parameters, such as horizontal-velocity difference and horizontal position difference of atomic clouds, horizontal-position difference of detectors and rotation compensation of Raman laser's mirror are calculated.
Journal ArticleDOI

Suppression of Coriolis error in weak equivalence principle test using 85 Rb- 87 Rb dual-species atom interferometer

TL;DR: In this article, the problem of Coriolis error in weak equivalence principle (WEP) test using atom interferometer has been studied theoretically and experimentally, and the measurement errors of Eötvõs coefficient (η) in WEP test related to experimental parameters, such as horizontal-velocity difference and horizontal-position difference of atomic clouds, horizontal position difference of detectors and rotation compensation of Raman laser's mirror are calculated.
Journal ArticleDOI

All acousto-optic modulator laser system for a 12 m fountain-type dual-species atom interferometer.

TL;DR: In this article, a laser system for 85Rb and 87Rb dual-species atom interferometers based on acousto-optic frequency shift and tapered amplifier laser technologies was proposed.