scispace - formally typeset
Search or ask a question
Institution

AOAC International

About: AOAC International is a based out in . It is known for research contribution in the topics: European union & Vitamin. The organization has 17 authors who have published 66 publications receiving 458 citations. The organization is also known as: Association of Official Agricultural Chemists & AOAC.


Papers
More filters
Journal ArticleDOI
TL;DR: Probability of Detection (POD) characterizes method response with respect to concentration as a continuous variable and provides a tool for graphical representation of response curves for qualitative methods.
Abstract: A statistical model is presented for use in validation of qualitative methods. This model, termed Probability of Detection (POD), harmonizes the statistical concepts and parameters between quantitative and qualitative method validation. POD characterizes method response with respect to concentration as a continuous variable. The POD model provides a tool for graphical representation of response curves for qualitative methods. In addition, the model allows comparisons between candidate and reference methods, and provides calculations of repeatability, reproducibility, and laboratory effects from collaborative study data. Single laboratory study and collaborative study examples are given.

103 citations

Journal ArticleDOI
TL;DR: A colorimetric method for the determination of total antioxidant activity in a variety of foods and beverages was validated in both a single-laboratory validation and a collaborative laboratory validation study.
Abstract: A colorimetric method for the determination of total antioxidant activity in a variety of foods and beverages was validated in both a single-laboratory validation and a collaborative laboratory validation study. The procedure involved extraction of the antioxidants directly into a methanol-water solution containing a known amount of 2,2'-diphenyl-1-picrylhydrazyl (DPPH), thus promoting the rapid reaction of extracted materials with DPPH. The reaction was monitored by spectrophotometric measurement of the absorbance loss at 517 nm. Antioxidant activity was quantified relative to a dilution series of vitamin E analog standards (Trolox), which were analyzed in parallel simultaneously with the food and beverage samples. The antioxidant activities of the samples ranged from 131 to 131 000 micromole Trolox equivalents/100 g. Statistical analysis of the results showed that nine of the 11 matrixes gave acceptable HorRat values, indicating that the method performed well in these cases. The acceptable matrixes include pomegranate juice, blueberry juice, carrot juice, green tea, wine, rosemary spice, ready-to-eat cereal, and yogurt. Two samples failed the HorRat test: the first was an almond milk that had an antioxidant level below the practical LOQ for the method; the second was a sample of canola oil with added omega-3 fatty acid that was immiscible in the reaction medium.

41 citations

Journal ArticleDOI
TL;DR: Based on the results from this study, 3M Petrifilm AC Plates are equivalent to standard plating methodology and can be used as an alternative procedure for the enumeration of test organisms used in AOAC Methods.
Abstract: A multilaboratory study was conducted to determine the equivalence of the 3M Petrifilm Aerobic Count Plate and standard plating methodology for measuring viable bacteria and spores recovered from hard-surface carriers (stainless steel and porcelain), also known as "control carrier counts," used in AOAC antimicrobial efficacy test methods. Six laboratories participated in the study in which carriers inoculated with Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella enterica, and spores of Bacillus subtilis were evaluated using 3M Petrifilm Aerobic Count (AC) plates and standard plating side-by-side. The data were analyzed using a matched-pair t-test to determine the between-method effect with confidence intervals. For all test organisms pooled across all laboratories, the mean difference in log10 concentration between the standard plate count method and 3M Petrifilm AC Plates was -0.012, with a 95% confidence interval of (-0.090, +0.066), which was well within the -0.5, +0.5 interval established as the acceptance criterion. The between-carrier SD averaged 0.139; the between-replicate SD was 0.050. The carrier reproducibility, given that a single replicate per carrier is done, was estimated to be 0.148. Although differences were seen in the final concentrations of the test organisms among laboratories, there were no statistical differences between the enumeration methods. Based on the results from this study, 3M Petrifilm AC Plates are equivalent to standard plating methodology and can be used as an alternative procedure for the enumeration of test organisms used in AOAC Methods 955.14, 955.15, 964.02, and 966.04.

22 citations

Journal ArticleDOI
TL;DR: The method for the determination of As, Cd, Hg, and Pb in foods by pressure digestion and inductively coupled plasma (ICP)/MS, previously published in J. AOAC Int.
Abstract: The method for the determination of As, Cd, Hg, and Pb in foods by pressure digestion and inductively coupled plasma (ICP)/MS, previously published in J. AOAC Int. 90, 844-856 (2007), was approved as First Action 2013.06 on April 9, 2013 by the Method- Centric Committee for Elemental Contaminants in Food. Digestion occurs using nitric acid in a closed vessel with elevated temperature and pressure by conventional or microwave-assisted heating. Determination occurs using ICP/MS. The elemental concentration ranges for As were 0.06-21.4, for Cd 0.03-28.3, for Hg 0.04-0.6, and for Pb 0.01-2.4 in mg/kg dry matter. The repeatability RSD (RSDr) ranged from 3.8 to 24% for As, 2.6 to 6.9% for Cd, 4.8 to 8.3% for Hg, and 2.9 to 27% for Pb. Reproducibility RSD (RSDR) ranged from 9.0 to 28% for As, 2.8 to 18% for Cd, 9.9 to 24% for Hg, and 8 to 50% for Pb.

22 citations


Network Information
Related Institutions (5)
Food and Drug Administration
19.5K papers, 691.2K citations

80% related

Center for Food Safety and Applied Nutrition
3K papers, 104.2K citations

79% related

Health Canada
6.2K papers, 291.9K citations

76% related

Central Science Laboratory
2K papers, 87.2K citations

73% related

PerkinElmer
4.7K papers, 102K citations

70% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20216
20203
20183
20178
20164
20151