Journal ArticleDOI
TL;DR: Hearing loss in older adults, in fact, is associated independently with poorer cognitive functioning, incident dementia, and falls, and it is suggested that treating hearing loss more aggressively could help delay cognitive decline and dementia.
Abstract: For some years, policy makers and medical scientists have both begun to focus more on chronic noncommunicable diseases. It is well known that cardio-cerebrovascular disease, tumors, diabetes, and chronic obstructive pulmonary disease (COPD), are considered areas of major interest in many scientific projects and health programs. The economic impact of cardio-cerebrovascular disease in EU alone is more than EUR 200 billion, while tumors have an impact of EUR 150 billion. The direct and indirect cost of brain disorders exceeds EUR 700 billion a year. Among the brain disorders, the devastating impact of dementia on affected individuals and the burden imposed on their families and society has made prevention and treatment of dementia a public health priority. Interventions that could merely delay the onset of dementia by 1 year would result in a more than 10% decrease in the global prevalence of dementia in 2050. Unfortunately, there are no known interventions that currently have such effectiveness. The manifestations of age-related hearing loss in many older adults are subtle and, thus, hearing loss is often perceived as an unfortunate but inconsequential part of aging. Researchers report that hearing loss seems to speed up age-related cognitive decline. Researchers suggest that treating hearing loss more aggressively could help delay cognitive decline and dementia. Furthermore, there is an increasing interest in better understanding the pathophysiologic correlations between hearing loss and dementia. Hearing loss in older adults, in fact, is associated independently with poorer cognitive functioning, incident dementia, and falls. Further research investigating the basis of this connection as well as the pathomechanism of the two diseases will further our ability to treat dementia.

530 citations


Journal ArticleDOI
TL;DR: Results indicate that image guidance can improve hearing outcomes for many existing CI recipients without requiring additional surgery or the use of ‘experimental' stimulation strategies, hardware or software.
Abstract: The cochlear implant (CI) has been labeled the most successful neural prosthesis. Despite this success, a significant number of CI recipients experience poor speech understanding, and, even among the best performers, restoration to normal auditory fidelity is rare. While significant research efforts have been devoted to improving stimulation strategies, few developments have led to significant hearing improvement over the past two decades. We have recently introduced image processing techniques that open a new direction for advancement in this field by making it possible, for the first time, to determine the position of implanted CI electrodes relative to the nerves they stimulate using computed tomography images. In this article, we present results of an image-guided, patient-customized approach to stimulation that utilizes the electrode position information our image processing techniques provide. This approach allows us to identify electrodes that cause overlapping stimulation patterns and to deactivate them from a patient's map. This individualized mapping strategy yields significant improvement in speech understanding in both quiet and noise as well as improved spectral resolution in the 68 adult CI recipients studied to date. Our results indicate that image guidance can improve hearing outcomes for many existing CI recipients without requiring additional surgery or the use of 'experimental' stimulation strategies, hardware or software.

116 citations


Journal ArticleDOI
TL;DR: Evaluating the prevalence of ARHL and cognitive impairment in a large sample of subjects older than 65 years and correlate hearing function with cognitive function showed that mild cognitive impairment (MCI) was significantly associated with hearing impairment (CAPD and hearing threshold; odds ratio 1.6, p = 0.05) and that Alzheimer's disease (AD) was significant associated with CAPD.
Abstract: Age-related hearing loss (ARHL) and dementia are two highly prevalent conditions in the adult population. Recent studies have suggested that hearing loss is independently associated with poorer cognitive functioning. The aim of this study was to evaluate the prevalence of ARHL and cognitive impairment in a large sample of subjects older than 65 years and to correlate hearing function with cognitive function. A total of 488 subjects older than 65 years (mean age 72.8 years) participating in the Great Age Study underwent a complete audiological, neurological and neuropsychological evaluation as part of a multidisciplinary assessment. The prevalence of a hearing loss greater than 25 dB HL was 64.1%, of Central Auditory Processing Disorder (CAPD) was 14.3 and 25.3% of the subjects reported a hearing handicap as reported on the Hearing Handicap Inventory for the Elderly Screening Version questionnaire. Multiple logistic regression analysis corrected for gender, age and education duration showed that mild cognitive impairment (MCI) was significantly associated with hearing impairment (CAPD and hearing threshold; odds ratio 1.6, p = 0.05) and that Alzheimer's disease (AD) was significantly associated with CAPD (odds ratio 4.2, p = 0.05). Given that up to 80% of patients affected by MCI convert to AD, adding auditory tests to a screening cognitive battery might have value in the early diagnosis of cognitive decline.

99 citations


Journal ArticleDOI
TL;DR: Investigating the degree and progression of hearing preservation over a longitudinal postoperative period in a large consecutive cohort of implanted patients with preoperative residual hearing indicated that residual hearing was preserved for the majority of implant patients with the Hybrid-L24 and the CI422 implant.
Abstract: Objectives: In recent years, it has been possible to preserve hearing after cochlear implantation in patients with significant amounts of low-frequency residual hearing. Due to the dimensions and characteristics of the cochlear implants (CIs) Nucleus® Hybrid™-L24 and Nucleus Freedom™ CI422, both can be used to preserve residual hearing. The aim was to investigate the degree and progression of hearing preservation over a longitudinal postoperative period in a large consecutive cohort of implanted patients with preoperative residual hearing who received either the Nucleus Hybrid-L24 or the Nucleus Freedom CI422 implant. The intention was to examine potential characteristics and triggers of resulting postoperative hearing loss which may support a differentiation of CI candidacy criteria for a certain implant type. Methods: A retrospective data analysis of patient files on consecutively implanted subjects presenting with a severe-to-profound sensorineural hearing loss at frequencies >1,500 Hz and substantial residual hearing at frequencies ≤1,500 Hz, implanted with a Nucleus Hybrid-L24 (n = 97) or a CI422 implant (n = 100), was undertaken. A single-subject repeated-measure design comparing the mean threshold shift for pure-tone thresholds under headphones up to 24 months after implantation was used. Results: Hearing preservation is observed in the majority of subjects with either implant (250-1,500 Hz frequency range). Hybrid-L24 patients exhibited a median hearing loss of 10 dB at initial fitting (n = 97) and of 15 dB after 24 months (n = 51). A 14.4-dB decrease in median hearing loss at initial fitting (n = 100) and a 30-dB decrease after 24 months (n = 28) was observed with the CI422 electrode. At initial fitting, 54.6% of the Hybrid-L24 (n = 97) and 49.0% of the CI422 (n = 100) subjects showed a mean threshold shift Conclusions: The results indicate that residual hearing was preserved for the majority of implanted patients with the Hybrid-L24 and the CI422 implant. Patients implanted with the Hybrid-L24 implant demonstrate greater stability and less median hearing loss over time than those with the CI422 implant. Assessments of onset and stability of hearing loss prior to implantation are important factors to consider during candidacy evaluation for electrode selection to potentially maximize the performance outcome for each patient.

92 citations


Journal ArticleDOI
TL;DR: Evidence is provided for the supposition that implant recipients with bilateral acoustic hearing have access to binaural cues, which should, in theory, provide greater benefit in noisy listening environments, and it is possible that in more realistic listening environments for which the diffuse noise is not directed toward the processor/hearing aid mic, hearing preservation patients have bINAural cues for improved speech understanding.
Abstract: The purpose of this study was to examine the availability of binaural cues for adult, bilateral cochlear implant (CI) patients, bimodal patients and hearing preservation patients using a multiple-baseline, observational study design. Speech recognition was assessed using the Bamford-Kowal-Bench Speech-in-Noise (BKB-SIN) test as well as the AzBio sentences [Spahr AJ, et al: Ear Hear 2012;33:112-117] presented in a multi-talker babble at a +5 dB signal-to-noise ratio (SNR). Test conditions included speech at 0° with noise presented at 0° (S0N0), 90° (S0N90) and 270° (S0N270). Estimates of summation, head shadow (HS), squelch and spatial release from masking (SRM) were calculated. Though nonwwe of the subject groups consistently showed access to binaural cues, the hearing preservation patients exhibited a significant correlation between summation and squelch whereas the bilateral and bimodal participants did not. That is to say, the two effects associated with binaural hearing - summation and squelch - were positively correlated only for the listeners with bilateral acoustic hearing. This finding provides evidence for the supposition that implant recipients with bilateral acoustic hearing have access to binaural cues, which should, in theory, provide greater benefit in noisy listening environments. It is likely, however, that the chosen test environment negatively affected the outcomes. Specifically, the spatially separated noise conditions directed noise toward the microphone (mic) port of the behind-the-ear (BTE) hearing aid and implant processor. Thus, it is possible that in more realistic listening environments for which the diffuse noise is not directed toward the processor/hearing aid mic, hearing preservation patients have binaural cues for improved speech understanding.

84 citations


Journal ArticleDOI
TL;DR: The present study is a brief literature review on the issues and prospects relating to the unique relationship between hearing and cognitive decline, with a general introduction to the main topics before focusing on rehabilitation training with hearing aids and cochlear implants to combat cognitive decline.
Abstract: Sensorineural systems play a crucial role in the diagnosis, treatment and management of several neurological disorders. The function of the eye and ear represents a unique window for testing various c

76 citations


Journal ArticleDOI
TL;DR: The long-term results of ABI surgery reveal significant auditory benefit in most children, and open set auditory recognition in many.
Abstract: Auditory brainstem implants (ABIs) can provide useful auditory perception and language development in deaf children who are not able to use a cochlear implant (CI). We prospectively followed up a consecutive group of 64 deaf children up to 12 years following ABI surgery. The etiology of deafness in these children was: cochlear nerve aplasia in 49, auditory neuropathy in 1, cochlear malformations in 8, bilateral cochlear postmeningitic ossification in 3, neurofibromatosis type 2 in 2, and bilateral cochlear fractures due to a head injury in 1. Thirty-five children had other congenital nonauditory disabilities. Twenty-two children had previous CIs with no benefit. Fifty-eight children were fitted with the Cochlear 24 ABI device and 6 with the MedEl ABI device, and all children followed the same rehabilitation program. Auditory perceptual abilities were evaluated on the Categories of Auditory Performance (CAP) scale. No child was lost to follow-up, and there were no exclusions from the study. All children showed significant improvement in auditory perception with implant experience. Seven children (11%) were able to achieve the highest score on the CAP test; they were able to converse on the telephone within 3 years of implantation. Twenty children (31.3%) achieved open set speech recognition (CAP score of 5 or greater) and 30 (46.9%) achieved a CAP level of 4 or greater. Of the 29 children without nonauditory disabilities, 18 (62%) achieved a CAP score of 5 or greater with the ABI. All children showed continued improvements in auditory skills over time. The long-term results of ABI surgery reveal significant auditory benefit in most children, and open set auditory recognition in many.

54 citations


Journal ArticleDOI
TL;DR: Clinical implications are that all aidable frequencies should be amplified in individuals with bimodal hearing, and verification of audibility at 125 Hz is unnecessary unless it is the only aidable frequency.
Abstract: We examined the effects of acoustic bandwidth on bimodal benefit for speech recognition in adults with a cochlear implant (CI) in one ear and low-frequency acoustic hearing in the contralateral ear. The primary aims were to (1) replicate Zhang et al. [Ear Hear 2010;31:63-69] with a steeper filter roll-off to examine the low-pass bandwidth required to obtain bimodal benefit for speech recognition and expand results to include different signal-to-noise ratios (SNRs) and talker genders, (2) determine whether the bimodal benefit increased with acoustic low-pass bandwidth and (3) determine whether an equivalent bimodal benefit was obtained with acoustic signals of similar low-pass and pass band bandwidth, but different center frequencies. Speech recognition was assessed using words presented in quiet and sentences in noise (+10, +5 and 0 dB SNRs). Acoustic stimuli presented to the nonimplanted ear were filtered into the following bands: <125, 125-250, <250, 250-500, <500, 250-750, <750 Hz and wide-band (full, nonfiltered bandwidth). The primary findings were: (1) the minimum acoustic low-pass bandwidth that produced a significant bimodal benefit was <250 Hz for male talkers in quiet and for female talkers in multitalker babble, but <125 Hz for male talkers in background noise, and the observed bimodal benefit did not vary significantly with SNR; (2) the bimodal benefit increased systematically with acoustic low-pass bandwidth up to <750 Hz for a male talker in quiet and female talkers in noise and up to <500 Hz for male talkers in noise, and (3) a similar bimodal benefit was obtained with low-pass and band-pass-filtered stimuli with different center frequencies (e.g. <250 vs. 250-500 Hz), meaning multiple frequency regions contain useful cues for bimodal benefit. Clinical implications are that (1) all aidable frequencies should be amplified in individuals with bimodal hearing, and (2) verification of audibility at 125 Hz is unnecessary unless it is the only aidable frequency.

52 citations


Journal ArticleDOI
TL;DR: Preoperative assessment of the distance between the round and oval windows may direct the surgeon before CI hearing-preservation surgery and showed that only very inferiorly located CO entered the scala tympani without causing trauma to the spiral ligament and spiral lamina.
Abstract: Background: The optimal insertion route for an electrode array in hearing preservation cochlear implantation (CI) surgery is still tentative. Both cochleostomy (CO) and round window (RW) techniques are used today. In the present study we analyzed size variations and topographic anatomy of the ‘hook' region of the human cochlea to better comprehend the Testo effects of various electric array insertion modes. Material and Methods: Size variations of the cochlear ‘hook' region were assessed in 23 human, microdissected temporal bones by measuring the distances between the oval and round windows, also outlining the spiral ligament/spiral lamina. Influence of size variations on spiral ligament position and fundamentals for different surgical approaches were evaluated in a subset of ‘small' and ‘large' cochleae performing different types of CO. In addition, the relationship between the microdissected accessory canal housing the inferior cochlear vein and the RW was analyzed. Results: The lateral vestibular wall and the cochlear ‘hook' displayed large anatomic variations that greatly influenced the size of the potential surgical area. Results showed that only very inferiorly located CO entered the scala tympani without causing trauma to the spiral ligament and spiral lamina. An inferior approach may challenge the inferior cochlear vein. Conclusion: Preoperative assessment of the distance between the round and oval windows may direct the surgeon before CI hearing-preservation surgery. CO techniques, especially in ‘small' ears, may lead to frequent damage to the inner ear structures. In those cases with substantial residual hearing, CI surgery may be better performed through a RW approach. i 2014 S. Karger AG, Basel

51 citations


Journal ArticleDOI
TL;DR: Analyses of predictive factors in this population provide a convincing argument to recommend treatment with cochlear implantation as early as possible in elderly patients with confirmed diagnosis of a severe-to-profound hearing loss and with only limited benefit from hearing aid use in one ear.
Abstract: Objective - To analyze predictive factors of cochlear implant outcomes and postoperative complications in the elderly. Study design - Prospective, longitudinal study performed in 10 tertiary referral centers. Methods - Ninety-four patients aged 65-85 years with a profound, postlingual hearing loss were evaluated before implantation, at time of activation, and 6 and 12 months after cochlear implantation. Speech perception and lipreading were measured using disyllabic word recognition in quiet and noise, and lipreading using disyllabic words and sentences. The influence of preoperative factors on speech perception in quiet and noise at 12 months was tested in a multivariate analysis. Complications, presence of tinnitus and of vestibular symptoms were collected at each evaluation. Results - The effect of age was observed only in difficult noisy conditions at SNR 0 dB. Lipreading ability for words and sentences was negatively correlated with speech perception in quiet and noise. Better speech perception scores were observed in patients with shorter duration of hearing deprivation, persistence of residual hearing for the low frequencies, the use of a hearing aid before implantation, the absence of cardiovascular risk factors, and in those with implantation in the right ear. General and surgical complications were very rare, and the percentage of vestibular symptoms remained stable over time. Conclusion - This study demonstrates that cochlear implantation in the elderly is a well-tolerated procedure and an effective method to improve communication ability. Advanced age has a low effect on cochlear implant outcome. Analyses of predictive factors in this population provide a convincing argument to recommend treatment with cochlear implantation as early as possible in elderly patients with confirmed diagnosis of a severe-to-profound hearing loss and with only limited benefit from hearing aid use in one ear.

45 citations


Journal ArticleDOI
TL;DR: It is found that CVRFs adversely affect hearing acuity and diagnosis should be accompanied by detecting and treating C VRFs, according to the presented outline, which may augment hearing rehabilitation and improve the general health and the well-being of the patient.
Abstract: The purpose of this paper is to provide a contemporary review of the correlation between cardiovascular risk factors (CVRFs) and hearing impairment (HI) . We conducted a comprehensive review of the literature in order to assess the effects of the different CVRFs on HI. We focused on the pathological findings in the inner ear and their correlation with cochlear function in population-based studies. We found that CVRFs adversely affect hearing acuity. HI diagnosis should be accompanied by detecting and treating CVRFs, according to the presented outline, which may augment hearing rehabilitation and improve the general health and the well-being of the patient. © 2014 S. Karger AG, Basel.

Journal ArticleDOI
TL;DR: Coupling the FMT to the short incus process may be a viable alternative in cases where the surgical approach is limited to an extended antrotomy.
Abstract: Introduction: Since 1996, the preferred approach for positioning the active middle-ear implant Vibrant Soundbridge© is a mastoidectomy and a posterior tympanotomy. With this device, placement of the floating mass transducer (FMT) on the long incus process is the standard method for treatment of mild-to-severe sensorineural hearing loss in the case of normal middle-ear anatomy. The aim of this study was to determine the vibrational effectiveness of FMT placement at the short incus process. Materials and Methods: An extended antrotomy and a posterior tympanotomy were performed in 5 fresh human temporal bones. As a control for normal middle-ear function, the tympanic membrane was stimulated acoustically and the vibration of the stapes footplate and the round-window (RW) membrane were (sequentially) measured by laser Doppler vibrometry. Vibration responses for coupling of an FMT to the long incus process (standard coupling) were compared to those for coupling to the short incus process. Results: Apart from narrow frequency bands near 3 and 9 kHz for the stapes footplate and RW membrane, respectively, the velocity responses presented no significant differences between standard coupling of the FMT and coupling to the short incus process. Conclusion: Coupling the FMT to the short incus process may be a viable alternative in cases where the surgical approach is limited to an extended antrotomy. A reliable technique for attachment to the short incus process has yet to be developed.

Journal ArticleDOI
TL;DR: It is found that patients with auditory symptoms have a larger dehiscence than patients with no auditory symptoms and the association between SCD length and location with air conduction loss and air-bone gap measured by pure-tone audiometric testing is examined.
Abstract: Superior canal dehiscence (SCD) is caused by an absence of bony covering of the arcuate eminence or posteromedial aspect of the superior semicircular canal. However, the clinical presentation of SCD syndrome varies considerably, as some SCD patients are asymptomatic and others have auditory and/or vestibular complaints. In order to determine the basis for these observations, we examined the association between SCD length and location with: (1) auditory and vestibular signs and symptoms; (2) air conduction (AC) loss and air-bone gap (ABG) measured by pure-tone audiometric testing, and (3) cervical vestibular-evoked myogenic potential (cVEMP) thresholds. 104 patients (147 ears) underwent SCD length and location measurements using a novel method of measuring bone density along 0.2-mm radial CT sections. We found that patients with auditory symptoms have a larger dehiscence (median length: 4.5 vs. 2.7 mm) with a beginning closer to the ampulla (median location: 4.8 vs. 6.4 mm from ampulla) than patients with no auditory symptoms (only vestibular symptoms). An increase in AC threshold was found as the SCD length increased at 250 Hz (95% CI: 1.7-4.7), 500 Hz (95% CI: 0.7-3.5) and 1,000 Hz (95% CI: 0.0-2.5), and an increase in ABG as the SCD length increased at 250 Hz (95% CI: 2.0-5.3), 500 Hz (95% CI: 1.6-4.6) and 1,000 Hz (95% CI: 1.3-3.3) was also seen. Finally, a larger dehiscence was associated with lowered cVEMP thresholds at 250 Hz (95% CI: -4.4 to -0.3), 500 Hz (95% CI: -4.1 to -1.0), 750 Hz (95% CI: -4.2 to -0.7) and 1,000 Hz (95% CI: -3.6 to -0.5) and a starting location closer to the ampulla at 250 Hz (95% CI: 1.3-5.1), 750 Hz (95% CI: 0.2-3.3) and 1,000 Hz (95% CI: 0.6-3.5). These findings may help to explain the variation of signs and symptoms seen in patients with SCD syndrome.

Journal ArticleDOI
TL;DR: Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.
Abstract: Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.

Journal ArticleDOI
TL;DR: Tinnitus is reduced after cochlear implantation in an important part of the patients, but in a small part implantation has a negative effect on tinnitus.
Abstract: This study retrospectively assessed the prevalence of tinnitus in cochlear implant patients and the changes after implantation in 212 patients implanted between 2000 and 2009. Patients were included at least 6 months after implantation and received 2 sets of questionnaires, one about the situation before implantation and one about the situation after implantation. Mostly standardized questionnaires assessed tinnitus handicap (Tinnitus Handicap Inventory, THI, and Tinnitus Handicap Questionnaire, THQ), tinnitus characteristics, hearing loss (Abbreviated Profile of Hearing Aid Benefit) and anxiety/depression (Hospital Anxiety and Depression Scale). Of the approached patients, 117 completed the full sets of questionnaires and 35 completed a short version. Preoperative tinnitus was reported by 51.3% of these patients, of which 55.6% reported a reduction or cessation of their tinnitus after implantation. However, 8.2% of the patients with tinnitus reported a postoperative deterioration of their tinnitus. In addition, among the patients without preoperative tinnitus, 19.6% reported the start of tinnitus after implantation. The self-reported change of tinnitus correlated with the pre- and postoperative scores on the THI and THQ. The THQ showed slightly more changes in scores after cochlear implantation compared to the THI. Overall hearing handicap and feelings of anxiety and depression decreased after implantation. In conclusion, tinnitus is reduced after cochlear implantation in an important part of the patients, but in a small part implantation has a negative effect on tinnitus. When tinnitus starts after implantation, the tinnitus handicap is mild.

Journal ArticleDOI
TL;DR: Evidence is provided supporting the long-term safety, feasibility and effectiveness of mastoid cartilage obliteration for children with suppurative cholesteatomatous ears and the potential for the delayed detection of recidivism with cavity obliteration.
Abstract: Objective: To analyze the long-term safety of mastoid obliteration with cartilage in children with suppurative cholesteatomatous ears. Methods:&

Journal ArticleDOI
TL;DR: The triamcinolone-acetonide-loaded poloxamer 407 hydrogel is an effective vehicle for sustained high-dose inner ear glucocorticoid delivery.
Abstract: The pharmacokinetic properties and tolerability of a triamcinolone acetonide poloxamer 407 hydrogel for intratympanic application were investigated in a guinea pig model. Evaluation of in vivo release kinetics showed very high initial perilymph drug levels, with clinically relevant levels present for a minimum of 10 days. Assessment of auditory brainstem response thresholds showed a minimal, delayed and transient threshold shift, which was apparent on day 3 and resolved by day 10. No relevant histological changes of the middle and inner ear structures were noted, and hair cell counts showed no significant differences between treated and untreated ears. Thus, the triamcinolone-acetonide-loaded poloxamer 407 hydrogel is an effective vehicle for sustained high-dose inner ear glucocorticoid delivery.

Journal ArticleDOI
Abstract: Otitis media (OM) represents a complex set of clinically defined disease phenotypes Epidemiological and pathological data suggest that inflammation of the middle ear occurs on a continuum of disease Here I review epidemiological data and apply mathematical modelling to better define the interrelation of OM phenotypes, including the relationship of upper respiratory tract infection to acute OM (AOM), of AOM to OM with effusion, and of recurrent OM to chronicity of effusion I use these mathematical models to represent OM graphically as a 'landscape of disease' This novel nosology may enable clinicians and researchers to better conceptualise middle ear inflammation in its various forms, although the limits of its application are also discussed

Journal ArticleDOI
TL;DR: The Epley maneuver was significantly more effective per maneuver than Semont or sham maneuvers for the short-term treatment of posterior canal BPPV and showed persistent resolution rates of positional vertigo and nystagmus without a fatigue phenomenon.
Abstract: We evaluated the short-term efficacy of Epley, Semont, and sham maneuvers for resolving posterior canal benign paroxysmal positional vertigo (BPPV) in a prospective multicenter randomized double-blind controlled study. Subjects were randomly divided into three groups: Epley (36 patients), Semont (32 patients), and sham (Epley maneuver for the unaffected side, 31 patients). Out of 14 institutes which participated in this study, 5 institutes had previous experience of the Epley but not the Semont maneuver and the other 9 had previous experience of both maneuvers. Each maneuver was repeated twice if there was still positional vertigo or nystagmus on day 0, and the presence of nystagmus and vertigo on positional testing were evaluated immediately, 1 day, and 1 week after treatment. After the first maneuver, the Epley group showed a significantly higher resolution rate of positional nystagmus than the Semont or sham groups (63.9, 37.5, and 38.7%, respectively). After the second maneuver, the resolution rate (83.3%) of the Epley group was significantly higher than that (51.6%) of the sham group. At 1 day and 1 week after treatment, the resolution rate of the Epley group was significantly higher than those of the other groups. Similar results were seen for the resolution of positional vertigo. The Epley maneuver showed persistent resolution rates of positional vertigo and nystagmus without a fatigue phenomenon. The Epley maneuver was significantly more effective per maneuver than Semont or sham maneuvers for the short-term treatment of posterior canal BPPV. The Semont maneuver showed a higher success rate than the sham maneuver, but it was not significantly different.

Journal ArticleDOI
TL;DR: Comparisons of auditory-cognitive processing in older-adult cochlear implants recipients with that of older normal-hearing listeners by means of behavioral and electrophysiologic manifestations of a high-load cognitive task suggest that the relative allotment of perceptual resources was substantially enhanced to maintain adequate performance in CI recipients.
Abstract: With the growing number of older adults receiving cochlear implants (CI), there is general agreement that substantial benefits can be gained. Nonetheless, variability in speech perception performance is high, and the relative contribution and interactions among peripheral, central-auditory, and cognitive factors are not fully understood. The goal of the present study was to compare auditory-cognitive processing in older-adult CI recipients with that of older normal-hearing (NH) listeners by means of behavioral and electrophysiologic manifestations of a high-load cognitive task. Auditory event-related potentials (AERPs) were recorded from 9 older postlingually deafened adults with CI (age at CI >60) and 10 age-matched listeners with NH, while performing an auditory Stroop task. Participants were required to classify the speaker's gender (male/female) that produced the words ‘mother' or ‘father' while ignoring the irrelevant congruent or incongruent word meaning. Older CI and NH listeners exhibited comparable reaction time, performance accuracy, and initial sensory-perceptual processing (i.e. N1 potential). Nonetheless, older CI recipients showed substantially prolonged and less efficient perceptual processing (i.e. P3 potential). Congruency effects manifested in longer reaction time (i.e. Stroop effect), execution time, and P3 latency to incongruent versus congruent stimuli in both groups in a similar fashion; however, markedly prolonged P3 and shortened execution time were evident in older CI recipients. Collectively, older adults (CI and NH) employed a combined perceptual and postperceptual conflict processing strategy; nonetheless, the relative allotment of perceptual resources was substantially enhanced to maintain adequate performance in CI recipients. In sum, the recording of AERPs together with the simultaneously obtained behavioral measures during a Stroop task exposed a differential time course of auditory-cognitive processing in older CI recipients that was not manifested in the behavioral end products of processing. These data may have implications regarding clinical evaluation and rehabilitation procedures that should be tailored specifically for this unique group of patients.

Journal ArticleDOI
TL;DR: DACI provides an effective improvement of the speech perception in noise compared to the best-aided condition in subjects suffering from severe to profound MHL.
Abstract: The aim of this study was to investigate the efficacy of a direct acoustic cochlear implant (DACI) for speech understanding in noise in patients suffering from severe to profound mixed hearing loss (MHL) due to various etiologies compared to the preoperative best-aided condition. The study was performed at five tertiary referral centers in Europe (Belgium, Germany, Poland and Spain). Nineteen adult subjects with severe to profound MHL due to (advanced) otosclerosis, ear canal fibrosis, chronic otitis media, tympanosclerosis or previous cholesteatoma were implanted with a DACI (Codacs™ Investigational Device) combined with a conventional stapes prosthesis. Unaided and aided speech reception scores in quiet and in noise, preoperative and postoperative air and bone conduction thresholds and aided and unaided sound field thresholds were measured prospectively during the study. Subjective benefit analysis was determined through the Abbreviated Profile of Hearing Aid Benefit questionnaire. Quality of life was measured by the Health Utilities Index. All subjects were fitted preoperatively with hearing aids and/or a bone conduction implant on a headband before DACI implantation. This allows direct comparison between different hearing rehabilitation solutions. The mean speech reception threshold in noise improved significantly by 7.9 dB signal-to-noise ratio (SNR) after activation of the DACI compared to the preoperative best-aided condition. For all 19 subjects, a mean postoperative aided speech reception threshold of 2.6 dB SNR (standard deviation: 8.3 dB) was measured. On average, no significant shift in the bone conduction thresholds was noted 4-5 months after implantation. A mean sound field threshold improvement of 46 and 16 dB was measured compared to the preoperative unaided and best-aided condition, respectively. Speech perception tests in quiet showed a mean improvement of the word recognition scores by 65 and 48% at 65 dB SPL compared to the preoperative unaided and best-aided condition, respectively. In summary, DACI provides an effective improvement of the speech perception in noise compared to the best-aided condition in subjects suffering from severe to profound MHL.

Journal ArticleDOI
TL;DR: The data suggest that acoustic signals perceived as significantly softer than a CI signal can contribute to speech understanding in the bimodal condition and acoustic signals presented at maximum comfortable loudness levels provide nearly as much benefit as signals that have been balanced with aCI signal.
Abstract: The aim of this project was to determine for bimodal cochlear implant (CI) patients, i.e. patients with low-frequency hearing in the ear contralateral to the implant, how speech understanding varies as a function of the difference in level between the CI signal and the acoustic signal. The data suggest that (1) acoustic signals perceived as significantly softer than a CI signal can contribute to speech understanding in the bimodal condition, (2) acoustic signals that are slightly softer than, or balanced with, a CI signal provide the largest benefit to speech understanding, and (3) acoustic signals presented at maximum comfortable loudness levels provide nearly as much benefit as signals that have been balanced with a CI signal.

Journal ArticleDOI
TL;DR: There was no significant difference in PTA improvement between the 2 study groups; the short-term IT protocol led to better results in the evaluation of the hearing outcomes (following the criteria of Siegel and Furuhashi et al.) for up- and down-sloping audiometric curves.
Abstract: Objectives: To assess the therapeutic effectiveness of an intratympanic (IT) steroid protocol compared to a systemic steroid protocol. Methods:&

Journal ArticleDOI
TL;DR: Speech recognition can be improved even in experienced cochlear implant listeners, and senior CI users with long-term CI experience may benefit in a similar way from an auditory, phoneme-based computer training program as younger CI users.
Abstract: Objectives: Cochlear implantation requires acclimatization to the electrical input. Usually, cochlear implant (CI) listeners undergo an auditory rehabilitation program that includes auditory training sessions. Recently, it was shown that a phoneme-based training may improve speech perception abilities even in experienced CI listeners. The current study focuses on whether the effect of an auditory training program depends on the age of CI listeners. Design: Fifteen CI listeners took part in an auditory phoneme-based computer training program. Before and after training, speech recognition tests in moderate and difficult noise (+5 dB SNR and 0 dB SNR, respectively) were administered. Additionally, speech recognition was tested 6 months after the training (follow-up). A control group consisting of 12 subjects underwent audiometric testing without any auditory training. Results: Speech perception in moderate noise improved significantly during the training as revealed by comparing pre- and posttraining scores evaluated in the moderate noise condition. No significant change was observed for the difficult noise situation at 0 dB SNR. The speech perception measures of the control group remained unchanged. No significant effect of age on the training effect was observed. Conclusion: Speech recognition can be improved even in experienced CI listeners. When motivated to participate, senior CI users with long-term CI experience may benefit in a similar way from an auditory, phoneme-based computer training program as younger CI users.

Journal ArticleDOI
TL;DR: A thorough knowledge of the anatomy of the skull base and the various skull base approaches is necessary to tackle GCTs, with good exposure of the tumor with minimal postoperative sequelae and good locoregional control.
Abstract: Objective: To study the clinical features, tumor characteristics and outcomes of giant cell tumors (GCTs) in the skull base based on long-term follow-up. We also

Journal ArticleDOI
TL;DR: Analysis based on participation restriction indicated that severe aural fullness leads to social isolation, and psychological factors and personal traits modify problems experienced by auralFullness.
Abstract: Objective: Aural fullness in M3ni2re's disease and the predisposing and consequential factors were investigated and possible consequences of aural fullness on par

Journal ArticleDOI
TL;DR: OVEMP recordings with the standard montage remain a reliable method for evaluation of SCDS, with excellent sensitivity and specificity.
Abstract: Objective: To compare the sensitivity and specificity of ocular vestibular evoked myogenic potentials (oVEMPs) using 2 electrode montages for the diagnosis of superior canal dehiscence syndrome (SCDS). Subjects: 16 SCDS patients (17 affected-SCDS ears, 15 contralateral-SCDS ears) and 12 controls (24 ears). Methods: oVEMPs were recorded in response to 500-Hz tone bursts using 2 electrode montages. For both montages the active electrode was placed approximately 5 mm below each eye and a ground electrode on the sternum. For montage 1 (standard), the reference electrode was centered 2 cm below each active electrode. For montage 2, the reference electrode was placed on the chin. Results: For either montage, the separation between oVEMP amplitudes in affected-SCDS ears and controls was significant (p 90%). Conclusion: oVEMP recordings with the standard montage remain a reliable method for evaluation of SCDS.

Journal ArticleDOI
TL;DR: Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated, and this imbalance is accompanied by an increased risk of falling in many patients.
Abstract: Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b).

Journal ArticleDOI
TL;DR: Observations suggest that subjects with a left sensorimotor dominance have developed more significant midline-crossing projections to the parietal cortex, allowing them to cope faster with a unilateral vestibular deficit.
Abstract: The subjective visual vertical (SVV) is an indicator of vestibular otolithic function and mainly processed by the nondominant parietal cortex. We investigated the hypothesis that recovery from SVV tilt after vestibular neuritis can be influenced by the body's lateral preference. This prospective cohort follow-up study included 254 consecutive adult patients with vestibular neuritis. The recovery from SVV tilt was faster in patients with a left hand or eye dominance than in those with a right dominance. While in left-handers the side of the neuritis did not affect the speed of recovery, in right-handed subjects, the recovery from a right-sided neuritis was significantly slower than from a left-sided affection. These observations suggest that subjects with a left sensorimotor dominance have developed more significant midline-crossing projections to the parietal cortex, allowing them to cope faster with a unilateral vestibular deficit.

Journal ArticleDOI
TL;DR: The pattern of vibration-induced VOR (ViVOR) is characterized by comparing the intensity and the axis of ViVOR with several clinical parameters of SCD and the location ofSCD with the vertical-to-torsional component ratio of the ViVORN was compared.
Abstract: A sound- and pressure-induced vestibuloocular reflex (VOR) has been described as vertical and torsional in superior canal dehiscence (SCD), and the rotational axes of induced VOR have been assumed to fit with the axis of the affected superior semicircular canal (SC). However, it has been difficult to characterize the pattern of vibration-induced VOR (ViVOR). We aimed to characterize the pattern of ViVOR by comparing the intensity and the axis of ViVOR with several clinical parameters of SCD. Ten symptomatic SCD patients were recruited. SCD size and location were measured on a reformatted image in the plane of the SC. Unilateral vibratory stimulation (100 Hz) was applied to the mastoid surface. ViVOR were recorded using 3D videooculography. The median 3D velocity of ViVOR was measured and the 3D vector trajectory plotted for reference against the axes of the human semicircular canals. A correlation between the magnitude of ViVOR and the size of SCD was evaluated. We also compared the location of SCD with the vertical-to-torsional component ratio of the ViVOR. ViVOR were present in 7 patients; 6 patients showed a substantial horizontal component in the excitatory direction in addition to strong torsional and weak vertical components. The computed rotational axes of ViVOR were located mostly between the axes of the ipsilateral SC and horizontal canal (HC) with a variable deviation to the axis of the ipsilateral posterior canal (PC). The magnitude of ViVOR was not related to the size of the SCD. The vertical-to-torsional component ratio of ViVOR tended to decline as the dehiscence was closer to the common crus. In SCD, mastoid vibration may stimulate the affected-side HC and PC as well as the SC. SCD can be suspected when excitatory horizontal torsional ViVOR direct to the side of the auditory symptoms.