scispace - formally typeset
Journal ArticleDOI

A synthetic double sampling control chart for the process mean

Reads0
Chats0
TLDR
In this paper, the authors proposed a synthetic double sampling chart that integrates the double sampling (DS) chart and the conforming run length chart, which offers performance improvements in terms of the zero-state Average Run Length (ARL) and Average Number of Observations to Sample (ANOS).
Abstract
This article proposes a synthetic double sampling chart that integrates the Double Sampling (DS) chart and the conforming run length chart. The proposed procedure offers performance improvements in terms of the zero-state Average Run Length (ARL) and Average Number of Observations to Sample (ANOS). When the size of a mean shift δ (given in terms of the number of standard deviation units) is small (i.e., between 0.4 and 0.6) and the mean sample size n= 5, the proposed procedure reduces the out-of-control ARL and ANOS values by nearly half, compared with both the synthetic and DS charts. In terms of detection ability versus the Exponentially Weighted Moving Average (EWMA) chart, the synthetic DS chart is superior to the synthetic or even the DS chart, as the former outperforms the EWMA chart for a larger range of δ values compared to the latter. The proposed procedure generally outperforms the EWMA chart in the detection of a mean shift when δ is larger than 0.5 and n= 5 or 10. Although the proposed procedu...

read more

Citations
More filters
Journal ArticleDOI

A synthetic control chart for the coefficient of variation

TL;DR: In this article, the salient features of the original CV chart and the conforming run length chart are integrated to produce a synthetic coefficient of variation (SynCV) chart, which is numerically compared with the originally proposed chart and upward EWMA-γ2 chart.
Journal ArticleDOI

A new synthetic control chart for monitoring process mean using auxiliary information

TL;DR: In this article, a new synthetic control chart that is based on a statistic that utilizes information from both the study and auxiliary variables was proposed and the proposed synthetic chart performs uniformly better than the classical synthetic chart when detecting different kinds of shifts in the process mean under both zerostate and steady-state run length performances.
Journal ArticleDOI

Optimal design of the double sampling X chart with estimated parameters based on median run length

TL;DR: It is argued that the median run length (MRL) provides a more intuitive and credible interpretation of a typical chart's performance and a new optimal design procedure is developed to compute the chart's optimal parameters for minimizing the out-of-control MRL.
Journal ArticleDOI

The Effect of Measurement Errors on the Synthetic x̄ Chart

TL;DR: The performance of the synthetic chart is investigated when measurement errors exist using a linearly covariate error model and shown that the performance is significantly affected in the presence of measurement errors.
Journal ArticleDOI

Optimal designs of the double sampling X¯ chart with estimated parameters

TL;DR: In this paper, the authors evaluate the performance of the DS X ¯ chart when process parameters are estimated by means of a new proposed theoretical method, and show that performances with estimated parameters are different from that with known parameters, and propose three optimal design procedures.
References
More filters
Journal ArticleDOI

Fast initial response for CUSUM quality-control schemes: give your CUSUM a head start

TL;DR: In this article, the average run length and the distribution of run length for CUSUM schemes with the fast initial response (FIR) feature were compared to standard CUSUME schemes.
Journal Article

Detecting a shift in fraction nonconforming using runlength control charts with 100% inspection

TL;DR: When 100% inspection in the order of production is in progress, an alternative approach to the p-chart or the Poisson-based CUSUM chart is to monitor the lengths of runs of conforming items between successive nonconforming items.
Journal ArticleDOI

Detecting a Shift in Fraction Nonconforming Using Run-Length Control Charts with 100% Inspection

TL;DR: When 100% inspection in the order of production is in progress, an alternative approach to the p-chart or the Poisson-based CUSUM chart is to monitor the lengths of runs of conforming items between successive nonconforming items.
Journal ArticleDOI

A Synthetic Control Chart for Detecting Small Shifts in the Process Mean

TL;DR: In this article, a synthetic control chart that is an integration of the Shewhart X chart and the conforming run length chart is presented, which is used to detect anomalies.
Journal Article

Double sampling X charts

TL;DR: In this article, the double sampling X chart is proposed, which is the counterpart to double sampling plans, which offers better statistical efficiency (in terms of statistical efficiency) than double sampling plan.
Related Papers (5)