A xenon gas scintillation proportional counter coupled to a photoionization detector

D.F. Anderson
- 01 Dec 1980 - 
- Vol. 178, Iss: 1, pp 125-130
Reads0
Chats0
TLDR
In this article, a photoionization detector was used to detect the light from a xenon filled gas scintillation proportional counter with an energy resolution of 9.5% fwhm.
About
This article is published in Nuclear Instruments and Methods.The article was published on 1980-12-01. It has received 56 citations till now. The article focuses on the topics: Photoionization detector & Scintillation.

read more

Citations
More filters
Journal ArticleDOI

Reflective UV photocathodes with gas-phase electron extraction: solid, liquid, and adsorbed thin films

TL;DR: In this article, the photoemission quantum efficiency of reflective photocathodes in methane gas has been investigated in the spectral range between 140 and 250 nm, and the spectral response of solid metals and CsI, as well as of liquid and solid TMAE film, have been measured.
Journal ArticleDOI

Theory of ring imaging Cherenkov counters

TL;DR: A short review of Cherenkov radiation and its use for particle identification with threshold and differential counters is presented in this article, where the focusing principles of Ring Imaging Cherankov (RICH) counters are then developed and applied successively to gas and liquid radiators.
Book

Gaseous Radiation Detectors: Fundamentals and Applications

TL;DR: In this article, the authors describe the drift and diffusion of charges in gases, collisional excitations and charge multiplication in uniform fields, and drift chambers and time projection chambers for time degeneracy and aging.
Journal ArticleDOI

A historical survey of ring imaging Cherenkov counters

TL;DR: Ring Imaging Cherenkov (RICH) counters as discussed by the authors have been used for particle identification since 1977, and have been classified into three groups, each developed over the last sixteen years, but based on different techniques and readout methods.
Journal ArticleDOI

Coupling of a BaF2 scintillator to a TMAE photocathode and a low-pressure wire chamber

TL;DR: In this article, the short wavelength component of a BaF2 scintillator has been successfully coupled to a tetrakis(dimethylamino)ethylene (TMAE) photocathode and a low-pressure wire chamber.
References
More filters
Journal ArticleDOI

Coded aperture imaging - Predicted performance of uniformly redundant arrays

TL;DR: A general expression for the signal-to-noise ratio (SNR) has been developed for the URA as a function of the type of object being imaged and the design parameters of the aperture.
Journal ArticleDOI

Ionization fluctuations and resolution of ionization chambers and semiconductor detectors

TL;DR: In this paper, the Fano factor for a variety of gases and for Si and Ge was calculated by Fano's approximate method, and the authors concluded that the ultimate fwhm of gas ionization chambers may be 7 keV at an α-particle energy of 6 MeV.
Journal ArticleDOI

Progress in high-accuracy proportional chambers

TL;DR: In this paper, the position of the ion cloud, using pulses induced in cathode strips arising from absorption of low-energy X-rays, is defined for ionizing events punctually localized in the volume of a proportional chamber, and the mean position of corresponding avalanches are well defined.
Journal ArticleDOI

Tomographical imaging using uniformly redundant arrays.

TL;DR: This paper investigates the performance of two URA apertures when used in a close-up tomographic imaging system and shows that a URA based on m sequences is superior to one based on quadratic residues.
Journal ArticleDOI

A large area, gas scintillation proportional counter

TL;DR: In this paper, an improved gas scintillation proportional counter with a measured overall energy resolution of 9.3% at 5.9 keV has been built, which is sufficiently well defined to allow the use of pulse-shape discrimination to reject 86% of the non-X-ray events in a space environment.
Related Papers (5)