scispace - formally typeset
Journal ArticleDOI

Motion artifact reduction in photoplethysmography using independent component analysis

B.S. Kim, +1 more
- 21 Feb 2006 - 
- Vol. 53, Iss: 3, pp 566-568
Reads0
Chats0
TLDR
The motion artifacts were reduced by exploiting the quasi-periodicity of the PPG signal and the independence between the P PG and the motion artifact signals by the combination of independent component analysis and block interleaving with low-pass filtering.
Abstract
Removing the motion artifacts from measured photoplethysmography (PPG) signals is one of the important issues to be tackled for the accurate measurement of arterial oxygen saturation during movement. In this paper, the motion artifacts were reduced by exploiting the quasi-periodicity of the PPG signal and the independence between the PPG and the motion artifact signals. The combination of independent component analysis and block interleaving with low-pass filtering can reduce the motion artifacts under the condition of general dual-wavelength measurement. Experiments with synthetic and real data were performed to demonstrate the efficacy of the proposed algorithm.

read more

Citations
More filters
Journal ArticleDOI

Dynamical analysis of biological signals with the 0-1 test

TL;DR: It is demonstrated that the PPG signal, as a time series, on a healthy individual, is a quasi-periodic signal.
Journal ArticleDOI

SPARE: A Spectral Peak Recovery Algorithm for PPG Signals Pulsewave Reconstruction in Multimodal Wearable Devices.

TL;DR: In this paper, a spectral peak recovery algorithm for photoplethysmographic (PPG) signals was proposed, which exploits the local semiperiodicity of the pulsewave signal, together with the information about the cardiac rhythm provided by an available simultaneous ECG, to reconstruct its full waveform, even when affected by strong artifacts.
Journal ArticleDOI

Evaluation of Objective Distortion Measures for Automatic Quality Assessment of Processed PPG Signals for Real-Time Health Monitoring Devices

- 01 Jan 2022 - 
TL;DR: In this article , the authors present four types of objective distortion measures and evaluate their performance in terms of quality prediction accuracy, Pearson correlation coefficient and computational time, which is performed on different kinds of PPG waveform distortions introduced by the predictive coding, compressed sampling, discrete cosine transform and discrete wavelet transform.
Proceedings ArticleDOI

FitBeat: A Lightweight System for Accurate Heart Rate Measurement during Exercise

TL;DR: Experimental results involving 10 subjects show that the average error of FitBeat is around 4 beats per minute, which improves heart rate accuracy of the default heart rate tracker of Moto 360 by 10x.
Journal ArticleDOI

Spot and continuous monitoring of heart rate by combining time and frequency domain analysis of photoplethysmographic signals at rest conditions

TL;DR: The results show that the proposed method is efficient in estimating the HR and the results are comparable with other methods, which can be targeted to wearable devices to accurately monitor the HR at rest conditions.
References
More filters
Book

Independent Component Analysis

TL;DR: Independent component analysis as mentioned in this paper is a statistical generative model based on sparse coding, which is basically a proper probabilistic formulation of the ideas underpinning sparse coding and can be interpreted as providing a Bayesian prior.
Journal ArticleDOI

Fast and robust fixed-point algorithms for independent component analysis

TL;DR: Using maximum entropy approximations of differential entropy, a family of new contrast (objective) functions for ICA enable both the estimation of the whole decomposition by minimizing mutual information, and estimation of individual independent components as projection pursuit directions.
Journal ArticleDOI

A dynamical model for generating synthetic electrocardiogram signals

TL;DR: A dynamical model based on three coupled ordinary differential equations is introduced which is capable of generating realistic synthetic electrocardiogram (ECG) signals and may be employed to assess biomedical signal processing techniques which are used to compute clinical statistics from the ECG.
BookDOI

Design of Pulse Oximeters

TL;DR: In this paper, the authors present a user interface for a pulse oximeter, based on an interface provided by Lozano-Nieto and Schowalter, with a discussion of the application of pulse oximetry.
Journal ArticleDOI

A new method for pulse oximetry possessing inherent insensitivity to artifact

TL;DR: It is demonstrated that this new methodology results in a reduced sensitivity to common classes of motion artifact, while retaining the generality to be combined with conventional signal processing techniques.