scispace - formally typeset
Journal ArticleDOI

Motion artifact reduction in photoplethysmography using independent component analysis

B.S. Kim, +1 more
- 21 Feb 2006 - 
- Vol. 53, Iss: 3, pp 566-568
TLDR
The motion artifacts were reduced by exploiting the quasi-periodicity of the PPG signal and the independence between the P PG and the motion artifact signals by the combination of independent component analysis and block interleaving with low-pass filtering.
Abstract
Removing the motion artifacts from measured photoplethysmography (PPG) signals is one of the important issues to be tackled for the accurate measurement of arterial oxygen saturation during movement. In this paper, the motion artifacts were reduced by exploiting the quasi-periodicity of the PPG signal and the independence between the PPG and the motion artifact signals. The combination of independent component analysis and block interleaving with low-pass filtering can reduce the motion artifacts under the condition of general dual-wavelength measurement. Experiments with synthetic and real data were performed to demonstrate the efficacy of the proposed algorithm.

read more

Citations
More filters
Journal ArticleDOI

Accurate face alignment and adaptive patch selection for heart rate estimation from videos under realistic scenarios.

TL;DR: This paper proposes a joint face detection and alignment method which can produce alignment-friendly facial bounding boxes with reliable initial facial shapes, facilitating accurate and robust face alignment even in the presence of large pose variations and expressions.
Proceedings ArticleDOI

A new approach for heart rate monitoring using photoplethysmography signals contaminated by motion artifacts

TL;DR: A novel HR estimation approach based on GRidless spectral Estimation and SVM-based peak Selection, denoted by GRESS, was proposed, which first obtained the sparse spectrum of PPG using a continuous dictionary, then a simple spectral subtraction step was adopted to remove MA, and finally an S VM-based method was developed to select the spectral peak corresponding to HR.
Proceedings ArticleDOI

Motion Artifact Reduction in Photoplethysmography using Bayesian Classification for Physical Exercise Identification

TL;DR: Experimental results on subjects performing two different exercises show that an improvement of about 50% in the accuracy of HR estimation is achieved with the proposed approach.
Journal ArticleDOI

CASINOR: Combination of adaptive filters using single noise reference signal for heart rate estimation from PPG signals

TL;DR: A new algorithm is proposed for the removal of MA component from the PPG signal using accelerometer signals, which resulted in less error value, less computational time and improved accuracy.
Journal ArticleDOI

Review on Heart-Rate Estimation from Photoplethysmography and Accelerometer Signals During Physical Exercise

TL;DR: Algorithms for denoising of PPG signals using accelerometer signals are either in time domain or frequency domain and the datasets used to develop these techniques are described.
References
More filters
Book

Independent Component Analysis

TL;DR: Independent component analysis as mentioned in this paper is a statistical generative model based on sparse coding, which is basically a proper probabilistic formulation of the ideas underpinning sparse coding and can be interpreted as providing a Bayesian prior.
Journal ArticleDOI

Fast and robust fixed-point algorithms for independent component analysis

TL;DR: Using maximum entropy approximations of differential entropy, a family of new contrast (objective) functions for ICA enable both the estimation of the whole decomposition by minimizing mutual information, and estimation of individual independent components as projection pursuit directions.
Journal ArticleDOI

A dynamical model for generating synthetic electrocardiogram signals

TL;DR: A dynamical model based on three coupled ordinary differential equations is introduced which is capable of generating realistic synthetic electrocardiogram (ECG) signals and may be employed to assess biomedical signal processing techniques which are used to compute clinical statistics from the ECG.
BookDOI

Design of Pulse Oximeters

TL;DR: In this paper, the authors present a user interface for a pulse oximeter, based on an interface provided by Lozano-Nieto and Schowalter, with a discussion of the application of pulse oximetry.
Journal ArticleDOI

A new method for pulse oximetry possessing inherent insensitivity to artifact

TL;DR: It is demonstrated that this new methodology results in a reduced sensitivity to common classes of motion artifact, while retaining the generality to be combined with conventional signal processing techniques.
Related Papers (5)