scispace - formally typeset
Search or ask a question

Showing papers by "David Montaigne published in 2020"


Journal ArticleDOI
TL;DR: Fast CS real-time single-breath-hold cine imaging reduces CMR scan duration by almost 20 times in daily practice while providing reliable measurements of both left and right ventricles.
Abstract: This study was conducted in order to evaluate the accuracy of a compressed sensing (CS) real-time single-breath-hold cine sequence for the assessment of left and right ventricular functional parameters in daily practice. Cardiac magnetic resonance (CMR) cine images were acquired from 100 consecutive patients using both the reference segmented multi-breath-hold steady-state free precession (SSFP) acquisition and a prototype single-breath-hold real-time CS sequence, providing the same slice number, position, and thickness. For both sequences, the left (LV) and right ventricular (RV) ejection fractions (EF) and end-diastolic volumes (EDV) were assessed as well as LV mass (LVM). The visualization of wall-motion disorders (WMD) and signal void related to mitral or tricuspid regurgitation was also analyzed. The CS sequence mean scan time was 23 ± 6 versus 510 ± 109 s for the multi-breath-hold SSFP sequence (p < 0.001). There was an excellent correlation between the two sequences regarding mean LVEF (r = 0.995), LVEDV (r = 0.997), LVM (r = 0.981), RVEF (r = 0.979), and RVEDV (r = 0.983). Moreover, inter- and intraobserver agreements were very strong with intraclass correlations of 0.96 and 0.99, respectively. On CS images, mitral or tricuspid regurgitation visualization was good (AUC = 0.85 and 0.81, respectively; ROC curve analysis) and wall-motion disorder visualization was excellent (AUC ≥ 0.97). CS real-time single-breath-hold cine imaging reduces CMR scan duration by almost 20 times in daily practice while providing reliable measurements of both left and right ventricles. There was no clinically relevant information loss regarding valve regurgitation and wall-motion disorder depiction. • Compressed sensing single-breath-hold real-time cine imaging is a reliable sequence in daily practice. • Fast CS real-time imaging reduces CMR scan time and improves patient workflow. • There is no clinically relevant information loss with CS regarding heart valve regurgitation or wall-motion disorders.

44 citations


Journal ArticleDOI
TL;DR: An association between higher TMAO concentrations and increased risk of MACE and all-cause mortality is revealed, thereby opening some avenues on the role of dysbiosis in cardiovascular risk, in T2D patients.
Abstract: OBJECTIVE Even though trimethylamine N-oxide (TMAO) has been demonstrated to interfere with atherosclerosis and diabetes pathophysiology, the association between TMAO and major adverse cardiovascular events (MACE) has not been specifically established in type 2 diabetes (T2D). RESEARCH DESIGN AND METHODS We examined the association of plasma TMAO concentrations with MACE and all-cause mortality in a single-center prospective cohort of consecutively recruited patients with T2D. RESULTS The study population consisted in 1463 SURDIENE participants (58% men), aged 65 ± 10 years. TMAO concentrations were significantly associated with diabetes duration, renal function, high-density lipoprotein cholesterol, soluble tumor necrosis factor receptor 1 (sTNFR1) concentrations (R2 = 0.27) and were significantly higher in patients on metformin, even after adjustment for estimated glomerular filtration rate (eGFR): 6.7 (8.5) vs 8.5 (13.6) µmol/L, respectively (PeGFR-adjusted = 0.0207). During follow-up (median duration [interquartile range], 85 [75] months), 403 MACE and 538 deaths were registered. MACE-free survival and all-cause mortality were significantly associated with the quartile distribution of TMAO concentrations, patients with the highest TMAO levels displaying the greatest risk of outcomes (P < 0.0001). In multivariate Cox models, compared with patients from the first 3 quartiles, those from the fourth quartile of TMAO concentration had an independently increased risk for MACE: adjusted hazard ratio (adjHR) 1.32 (1.02-1.70); P = 0.0325. Similarly, TMAO was significantly associated with mortality in multivariate analysis: adjHR 1.75 (1.17-2.09); P = 0.0124, but not when sTNFR1 and angiopoietin like 2 were considered: adjHR 1.16 (0.95-1.42); P = 0.1514. CONCLUSIONS We revealed an association between higher TMAO concentrations and increased risk of MACE and all-cause mortality, thereby opening some avenues on the role of dysbiosis in cardiovascular risk, in T2D patients.

32 citations


Journal ArticleDOI
TL;DR: In this paper, the authors quantified IFNγsecreting T cells reactive against the main viral SARS-CoV-2 antigens using a standardised enzyme-linked immunospot assay (ELISpot).
Abstract: Objectives : Assessment of the adaptive immune response against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is crucial for studying long-term immunity and vaccine strategies. We quantified IFNγ-secreting T cells reactive against the main viral SARS-CoV-2 antigens using a standardised enzyme-linked immunospot assay (ELISpot). Methods : Overlapping peptide pools built from the sequences of M, N and S viral proteins and a mix (MNS) were used as antigens. Using IFNγ T-CoV-Spot assay, we assessed T-cell and antibody responses in mild, moderate and severe SARS-CoV-2 patients and in control samples collected before the outbreak. Results : Specific T cells were assessed in 60 consecutive patients (mild, n = 26; moderate, n = 10; and severe patients, n = 24) during their follow-up (median time from symptom onset [interquartile range]: 36 days [28;53]). T cells against M, N and S peptide pools were detected in n = 60 (100%), n = 56 (93.3%), n = 55 patients (91.7%), respectively. Using the MNS mix, IFNγ T-CoV-Spot assay showed a specificity of 96.7% (95% CI, 88.5–99.6%) and a specificity of 90.3% (75.2–98.0%). The frequency of reactive T cells observed with M, S and MNS mix pools correlated with severity and with levels of anti-S1 and anti-RBD serum antibodies. Conclusion : IFNγ T-CoV-Spot assay is a reliable method to explore specific T cells in large cohorts of patients. This test may become a useful tool to assess the long-lived memory T-cell response after vaccination. Our study demonstrates that SARS-CoV-2 patients developing a severe disease achieve a higher adaptive immune response.

26 citations


Journal ArticleDOI
TL;DR: Exposure to elevated serum TN-C concentrations at enrolment in participants with type 2 diabetes would be associated with increased risk of death and major adverse CV events (MACE) during follow-up, and includingTN-C as a prognostic biomarker could improve risk stratification in these individuals.
Abstract: Tenascin-C (TN-C) is an extracellular matrix glycoprotein highly expressed in inflammatory and cardiovascular (CV) diseases. Serum TN-C has not yet been specifically studied in individuals with type 2 diabetes, a condition associated with chronic low-grade inflammation and increased CV disease risk. In this study, we hypothesised that elevated serum TN-C at enrolment in participants with type 2 diabetes would be associated with increased risk of death and major adverse CV events (MACE) during follow-up. We used a prospective, monocentric cohort of consecutive type 2 diabetes participants (the SURDIAGENE [SUivi Renal, DIAbete de type 2 et GENEtique] cohort) with all-cause death as a primary endpoint and MACE (CV death, non-fatal myocardial infarction or stroke) as a secondary endpoint. We used a proportional hazard model after adjustment for traditional risk factors and the relative integrated discrimination improvement (rIDI) to assess the incremental predictive value of TN-C for these risk factors. We monitored 1321 individuals (58% men, mean age 64 ± 11 years) for a median of 89 months. During follow-up, 442 individuals died and 497 had MACE. Multivariate Cox analysis showed that serum TN-C concentrations were associated with an increased risk of death (HR per 1 SD: 1.27 [95% CI 1.17, 1.38]; p < 0.0001) and MACE (HR per 1 SD: 1.23 [95% CI 1.13, 1.34]; p < 0.0001). Using TN-C concentrations on top of traditional risk factors, prediction of the risk of all-cause death (rIDI: 8.2%; p = 0.0006) and MACE (rIDI: 6.7%; p = 0.0014) improved significantly, but modestly. In individuals with type 2 diabetes, increased serum TN-C concentrations were independently associated with death and MACE. Therefore, including TN-C as a prognostic biomarker could improve risk stratification in these individuals.

16 citations


Journal ArticleDOI
TL;DR: An elevated renal resistive index with a threshold of 0.7 is an independent predictor of a first cardiovascular or renal event in type 2 diabetic patients, and this simple index should be implemented in the multiparametric staging of diabetes.
Abstract: The renal resistive index has been demonstrated to predict the progression of renal disease and recurrence of major cardiac events in high-risk cardiovascular patients, in addition to other comorbidities. We aimed to assess the prognostic significance of the renal resistive index in type 2 diabetic patients for primary prevention. From 2008 to 2011, patients with type 2 diabetes underwent cardiovascular evaluation, including renal resistive index assessment by renal Doppler ultrasound. The incidence of all-cause death, cardiovascular events, dialysis requirement or a twofold increase in creatinine was recorded. Survival curves were estimated by the Kaplan-Meier method. Two hundred sixty-six patients were included; 50% of the patients were men, an HbA1C level of 8.1 ± 1.7% (65 ± 13.6 mmol/mol) and a serum creatinine level of 8 [7-9] mg/L. The mean 24-hour systolic blood pressure, 24-hour diastolic blood pressure, and 24-hour pulse pressure were 133.4 ± 16.7, 76.5 ± 9.4, and 56.9 ± 12.4 mm Hg, respectively. The median renal resistive index was 0.7 [0.6-0.7] with a threshold of 0.7 predictive of monitored events. After adjustment of the 24-hour pulse pressure, age and 24-hour heart rate, a renal resistive index ≥0.70 remained associated with all-cause death (hazard ratio: 3.23 (1.16-8.98); P = .025) and the composite endpoint of major clinical events (hazard ratio: 2.37 (1.34-4.18); P = .003). An elevated renal resistive index with a threshold of 0.7 is an independent predictor of a first cardiovascular or renal event in type 2 diabetic patients. This simple index should be implemented in the multiparametric staging of diabetes.

8 citations


Journal ArticleDOI
TL;DR: Pre-operative ECG markers of myocardial damage identify a subgroup of AS patients at high risk of post-AVR cardiovascular complications irrespective of other prognostic factors and should help the multiparametric staging of cardiac damage to guide AVR.

8 citations


Journal ArticleDOI
TL;DR: Three-dimensional TEE measurements of MA dimensions display strong correlations with CT measurements in patients undergoing TMVR screening and should be proposed as a reasonable alternative to CT imaging in this vulnerable population.
Abstract: Background Three-dimensional (3D) transesophageal echocardiographic (TEE) imaging is frequently used as an initial screening tool in the evaluation of patients who are candidates for transcatheter mitral valve replacement (TMVR). However, little is known about the imaging correlation with the gold standard, computed tomographic (CT) imaging. The aims of this study were to test the quantitative differences between these two modalities and to determine the best 3D TEE parameters for TMVR screening. Methods Fifty-seven patients referred to the heart valve clinic for TMVR with prostheses specifically designed for the mitral valve were included. Mitral annular (MA) analyses were performed using commercially available software on 3D TEE and CT imaging. Results Three-dimensional TEE imaging was feasible in 52 patients (91%). Although 3D TEE measurements were slightly lower than those obtained on CT imaging, measurements of both projected MA area and perimeter showed excellent correlations, with small differences between the two modalities (r = 0.88 and r = 0.92, respectively, P Conclusions Three-dimensional TEE measurements of MA dimensions display strong correlations with CT measurements in patients undergoing TMVR screening. Three-dimensional TEE imaging should be proposed as a reasonable alternative to CT imaging in this vulnerable population.

6 citations


Journal ArticleDOI
TL;DR: Both pre-operative planning and periprocedural guidance of transcatheter mitral valve replacement (TMVR) are based on the independent analysis of transesophageal echocardiography and computed tomography scanner images.
Abstract: Both pre-operative planning and periprocedural guidance of transcatheter mitral valve replacement (TMVR) are based on the independent analysis of transesophageal echocardiography (echo) and computed tomography scanner (CT) images ([1][1]). Echo-CT fusion (Vivid E95, GE Healthcare, Horten, Norway) ([

5 citations



Journal ArticleDOI
TL;DR: Patients with aortic stenosis and prior mediastinal radiotherapy (XRT) represent a challenging group and the detrimental effects due to the pressure overload associated with AS may be compounded by the presence of radiation heart disease.
Abstract: Patients with aortic stenosis (AS) and prior mediastinal radiotherapy (XRT) represent a challenging group ([1–3][1]). The detrimental effects due to the pressure overload associated with AS may be compounded by the presence of radiation heart disease. Echocardiographic speckle-tracking strain

3 citations