scispace - formally typeset
Search or ask a question

Showing papers by "Roger J. Zemp published in 2016"


Journal ArticleDOI
01 Jan 2016-Small
TL;DR: Porphyrin nanodroplets may be useful for enhancing the visualization of tumors with ultrasound and/or photoacoustic imaging, and may be phase-changed into microbubbles using high pressure ultrasound, providing ultrasound contrast with single-bubble sensitivity.
Abstract: A novel class of all-organic nanoscale porphyrin nanodroplet agents is presented which is suitable for multimodality ultrasound and photoacoustic molecular imaging. Previous multimodality photoacoustic-ultrasound agents are either not organic, or not yet demonstrated to exhibit enhanced accumulation in leaky tumor vasculature, perhaps because of large diameters. In the current study, porphyrin nanodroplets are created with a mean diameter of 185 nm which is small enough to exhibit the enhanced permeability and retention effect. Porphyrin within the nanodroplet shell has strong optical absorption at 705 nm with an estimated molar extinction coefficient >5 × 10(9) m(-1) cm(-1) , allowing both ultrasound and photoacoustic contrast in the same nanoparticle using all organic materials. The potential of nanodroplets is that they may be phase-changed into microbubbles using high pressure ultrasound, providing ultrasound contrast with single-bubble sensitivity. Multispectral photoacoustic imaging allows visualization of nanodroplets when injected intratumorally in an HT1080 tumor in the chorioallantoic membrane of a chicken embryo. Intravital microscopy imaging of Hep3-GFP and HT1080-GFP tumors in chicken embryos determines that nanodroplets accumulated throughout or at the periphery of tumors, suggesting that porphyrin nanodroplets may be useful for enhancing the visualization of tumors with ultrasound and/or photoacoustic imaging.

80 citations


Journal ArticleDOI
TL;DR: Improved variants are identified with a 02–04 fold increase in photoacoustic signal-to-noise ratio after only a few evolutionary steps and enable more accurate spectral de-mixing and localization of protein-producing bacteria in vivo and serve as effective FRET acceptors for both fluorescence- and photoac acoustic-based detection of protease activity.
Abstract: A subset of the family of fluorescent proteins are the non-fluorescent chromoproteins which are promising probe molecules for use in photoacoustic imaging and as acceptor chromophores in Forster resonance energy transfer (FRET)-based biosensors. Typical approaches for fluorescent protein optimization by screening of large libraries of variants cannot be effectively applied to chromoproteins due to their characteristic lack of fluorescence. To address this challenge, we have developed a directed evolution method to iteratively screen large libraries of protein variants on the basis of their photoacoustic signal levels. By applying this procedure to the promising Ultramarine and cjBlue chromoprotein templates, we were able to identify improved variants with a 02–04 fold increase in photoacoustic signal-to-noise ratio after only a few evolutionary steps. These improved variants enable more accurate spectral de-mixing and localization of protein-producing bacteria in vivo and serve as effective FRET acceptors for both fluorescence- and photoacoustic-based detection of protease activity.

33 citations


Journal ArticleDOI
TL;DR: An automated speech-recognition-inspired classification algorithm for the acoustic diagnosis of PH that outperforms physicians that could be used to screen for PH and encourage earlier specialist referral is developed.
Abstract: We hypothesized that an automated speech- recognition-inspired classification algorithm could differentiate between the heart sounds in subjects with and without pulmonary hypertension (PH) and outperform physicians. Heart sounds, electrocardiograms, and mean pulmonary artery pressures (mPAp) were recorded simultaneously. Heart sound recordings were digitized to train and test speech-recognition-inspired classification algorithms. We used mel-frequency cepstral coefficients to extract features from the heart sounds. Gaussian-mixture models classified the features as PH (mPAp ≥ 25 mmHg) or normal (mPAp < 25 mmHg). Physicians blinded to patient data listened to the same heart sound recordings and attempted a diagnosis. We studied 164 subjects: 86 with mPAp ≥ 25 mmHg (mPAp 41 ± 12 mmHg) and 78 with mPAp < 25 mmHg (mPAp 17 ± 5 mmHg) (p < 0.005). The correct diagnostic rate of the automated speech-recognition-inspired algorithm was 74% compared to 56% by physicians (p = 0.005). The false positive rate for the algorithm was 34% versus 50% (p = 0.04) for clinicians. The false negative rate for the algorithm was 23% and 68% (p = 0.0002) for physicians. We developed an automated speech-recognition-inspired classification algorithm for the acoustic diagnosis of PH that outperforms physicians that could be used to screen for PH and encourage earlier specialist referral.

14 citations


Journal ArticleDOI
TL;DR: The fundamental framework for mutual-acoustic impedance for its applicability to radiators, especially flexural disks, of differing size is revisited and may prove valuable for future design of multi-frequency arrays for novel multiscale imaging, superharmonic contrast imaging, and image therapy applications.
Abstract: Multi-frequency capacitive micromachined ultrasonic transducers (CMUTs) consist of interlaced large and small membranes for multiband operation. In modeling these devices, accurate and computationally efficient methods are required for computing self- and mutual-acoustic-radiation impedances. However, most previous works considered mutual-acoustic impedance between radiators of identical size. A need was thus found to revisit the fundamental framework for mutual-acoustic impedance for its applicability to radiators, especially flexural disks, of differing size. The Bouwkamp integral method is used to achieve infinite series expressions for self- and mutual-acoustic radiation impedances. Polynomial-fitting-based approximate relations of the mutual-acoustic impedance are developed for arbitrary array geometries and are in good agreement with exact expressions. The derived mutual-acoustic impedance is incorporated into equivalent circuit models of multi-frequency CMUTs showing excellent agreement with finite element modeling. The results demonstrate that mutual-acoustic interactions significantly impact device performance. The framework presented here may prove valuable for future design of multi-frequency arrays for novel multiscale imaging, superharmonic contrast imaging, and image therapy applications.

14 citations


Journal ArticleDOI
TL;DR: In this paper, a technique called lifetime-weighted imaging was proposed to quantify the lifetime profile of exogenous agents using a series of pump-probe pulses with a varying time delay.
Abstract: Photoacoustic (PA) imaging has been utilized to quantify the lifetime profile of exogenous agents using a series of pump-probe pulses with a varying time delay; however, current techniques typically lead to long acquisition times which are sensitive to motion and cause absorption or photobleaching. We introduce a technique called lifetime-weighted imaging, which uses only three laser pulses to preferentially weight signals from chromophores with long lifetimes (including exogenous contrast agents with triplet excited states such as methylene blue and porphyrins) while nulling chromophores with short picosecond- to nanosecond-scale lifetimes (including hemoglobin). This technique detects the PA signal from a probe pulse either with or without a pump pulse. By subtracting the probe-only signal from the pump-present probe signal, we effectively eliminate signals from chromophores with short lifetimes while preserving PA signals from chromophores with long-lifetimes. We demonstrate the oxygen-dependent lifetime of both methylene blue and porphyrin-lipids and demonstrate both ground-state recovery and excited-state lifetime-weighted imaging. Lifetime-weighted PA imaging may have applications in many molecular imaging application including: photodynamic therapy dosimetry guidance and oxygen sensing.

10 citations


Journal ArticleDOI
TL;DR: This system has ultralow background and can detect tumor cells labeled with modified surface-enhanced-Raman-scattering (SERS) nanoparticles in vivo and can potentially be used to guide magnetic trapping of circulating tumor cells for SERS detection in animal models.
Abstract: A multimodality Raman and photoacoustic imaging system is presented. This system has ultralow background and can detect tumor cells labeled with modified surface-enhanced-Raman-scattering (SERS) nanoparticles in vivo. Photoacoustic imaging provides microvascular context and can potentially be used to guide magnetic trapping of circulating tumor cells for SERS detection in animal models.

8 citations


Proceedings ArticleDOI
TL;DR: A compact photoacoustic transrectal probe is constructed for improved imaging in brachytherapy treatment, and the tuneable excitation in combination with standard US integration provides adjustable contrast between the brachyTherapy seeds, blood filled tubes and background tissue.
Abstract: A compact photoacoustic transrectal probe is constructed for improved imaging in brachytherapy treatment. A 192 element 5 MHz linear transducer array is mounted inside a small 3D printed casing along with an array of optical fibers. The device is fed by a pump laser and tunable NIR-optical parametric oscillator with data collected by a Verasonics ultrasound platform. This assembly demonstrates improved imaging of brachytherapy seeds in phantoms with depths up to 5 cm. The tuneable excitation in combination with standard US integration provides adjustable contrast between the brachytherapy seeds, blood filled tubes and background tissue.

7 citations


Journal ArticleDOI
TL;DR: In this paper, an angiocatheter was temporarily implanted subcutaneously, which facilitated angiogenesis to promote subsequent islet engraftment, and photoacoustic imaging was used to track angiogenogenesis during the priming of the subcutaneous site by the implanted catheter at 1 to 4 weeks postcatheter.
Abstract: Islet transplantation (IT) is an established clinical therapy for select patients with type-1 diabetes. Clinically, the hepatic portal vein serves as the site for IT. Despite numerous advances in clinical IT, limitations remain, including early islet cell loss posttransplant, procedural complications, and the inability to effectively monitor islet grafts. Hence, alternative sites for IT are currently being explored, with the subcutaneous space as one potential option. When left unmodified, the subcutaneous space routinely fails to promote successful islet engraftment. However, when employing the previously developed subcutaneous “deviceless” technique, a favorable microenvironment for islet survival and function is established. In this technique, an angiocatheter was temporarily implanted subcutaneously, which facilitated angiogenesis to promote subsequent islet engraftment. This technique has been employed in preclinical animal models, providing a sufficient means to develop techniques to monitor functional aspects of the graft such as angiogenesis. Here, we utilize photoacoustic imaging to track angiogenesis during the priming of the subcutaneous site by the implanted catheter at 1 to 4 weeks postcatheter. Quantitative analysis on vessel densities shows gradual growth of vasculature in the implant position. These results demonstrate the ability to track angiogenesis, thus facilitating a means to optimize and assess the pretransplant microenvironment.

4 citations


Proceedings ArticleDOI
01 Sep 2016
TL;DR: In this paper, an accurate nonlinear lumped equivalent circuit model including the effects of the self and mutual acoustic interactions between CMUT cells was used for modeling of multi-frequency CMUT arrays.
Abstract: Large-scale multi-frequency capacitive micromachined ultrasonic transducer (CMUT) arrays consist of thousands of closely packed interlaced large and small membranes for applications such as super-harmonic imaging, multi-band operation, imaging-therapy, contrast and photoacoustic imaging. An accurate nonlinear lumped equivalent circuit model including the effects of the self and mutual acoustic interactions between CMUT cells was used for modeling of multi-frequency CMUT arrays. Recently, we showed precise models for simulating the behavior of multi-frequency CMUT arrays including a few number of cells with excellent agreements with FEM and experimental results. In this work the model was extended to simulate large-scale multi-frequency CMUT arrays for realistic ultrasound applications which is not feasible with FEM analysis. The models predicted the effects of the mutual radiation impedance between cells with dissimilar sizes for complex and large-scale arrays. The effects of different biasing methods were evaluated on performance of the array for different sets of CMUT parameters. This tool can be used to optimize the performance of the multi-frequency CMUT arrays before fabrication.

4 citations


Proceedings ArticleDOI
TL;DR: In this paper, the authors investigated a PA methodology using pulsed fiber laser sources as excitation laser source combined with lock-in amplification technology, and they showed that the signal-to-noise ratio (SNR) obtained with frequency domain PA imaging is significantly more sensitive than that obtained using time-domain PA imaging when the laser pulse repetition rate (PRR) matches the bandwidth of ultrasound transducer.
Abstract: Photoacoustic (PA) imaging is a non-invasive, non-ionizing imaging technology with high optical contrast between blood and tissue, and with high sensitivity of hemoglobin concentration and oxygen saturation due to different optical absorption spectra resulting from different oxygenation of hemoglobin. Most PA imaging systems implement a nanosecond pulsed laser source as excitation source to induce PA signal, and rely on broadband amplifiers to record time-domain PA signals [1-6]. Some groups, however, have reported using modulated continuous-wave lasers as an excitation source for frequency-domain imaging [7-9]. Frequency-domain imaging offers the potential of lock-in amplification which has sensitivities as low as nV even in noise orders of magnitude higher than the signal. However, although modulated CW sources works for low cost and compact PA imaging, it does not satisfy thermal and stress confinement conditions required for optimal PA signal strength. Here, we investigate a PA methodology using pulsed fiber lasers as excitation laser source combined with lock-in amplification technology. For comparison, we also studied time-domain PA methodology. Phantom studies show that signal-to-noise ratio (SNR) obtained with frequency domain PA imaging is significantly more sensitive than that obtained using time-domain PA imaging when the laser pulse repetition rate (PRR) matches the bandwidth of ultrasound transducer. Therefore, high sensitive PA imaging technology using pulsed fiber laser sources with lock-in amplification may potentially greatly extend the depth of PA imaging.

2 citations


Proceedings ArticleDOI
TL;DR: In this article, a photoacoustic-ultrasound tomography system capable of multiple illuminations and parallel acquisition from a 256 element 5 MHz transducer ring array with 8 cm diameter is presented.
Abstract: Previously we described the potential for multiple illumination photoacoustic tomography to provide quantitative reconstructions, however this work used only simulated data. We have developed a custom photoacoustic-ultrasound tomography system capable of multiple illuminations and parallel acquisition from a 256 element 5 MHz transducer ring array with 8-cm diameter. The multiple illumination scheme uses a free-space light delivery geometry where a rotational stage scans a pulsed laser beam onto different incident locations around the sample. For each illumination location a photoacoustic image is reconstructed using a modified backprojection algorithm. Images from different source locations have the potential to be combined to form an improved deep-tissue image using our previously developed iterative algorithms. We complement the photoacoustic imaging data with unique ultrasound imaging data. Most previous ultrasound tomography methods have used migration algorithms, iterative ray-based analysis, wave-equation modeling, or frequency-based algorithms that all demand large amounts of data and computational power. We propose a new UST method that offers isotropic resolution, provides scattering contrast, as well as the potential for measuring ultrasound scattering anisotropy and decoupling density and compressibility contributions. The imaging system is driven by a Verasonics scan engine and programmed for both ultrasound and photoacoustic imaging modes. Resolution has been measured to be 150 μm for ultrasound and 200 μm for photoacoustic images. Imaging capabilities are demonstrated on phantoms with custom-tailored ultrasound scattering and optical properties, as well as in murine models.

Proceedings ArticleDOI
TL;DR: The ability to track angiogenesis in mice with 1, 2, 3 and 4 weeks post-catheter implant on both sides of the abdomen using a FujiFilm VisualSonics Vevo-LAZR system is demonstrated.
Abstract: Exogenous insulin administration is the mainstay treatment therapy for patients with Type-1 diabetes mellitus (T1DM). However, for select patients, clinical islet transplantation is an alternative therapeutic treatment. In this procedure, islets are transplanted into the hepatic portal vein, and despite improved success within the last decade, obstacles are still associated with this approach. It has been discovered that the subcutaneous space may be an effective alternative site for islet transplantation, and may provide advantages of easy access and potential for simple monitoring. The ability to monitor islet viability and the transplant microenvironment may be key to future success in islet transplantation. A subcutaneous device-less technique has been developed to facilitate angiogenesis in the islet transplant site, however, a method for monitoring the potential engraftment site have yet to be explored fully. Here we demonstrate the ability to track angiogenesis in mice with 1, 2, 3 and 4 weeks post-catheter implant on both sides of the abdomen using a FujiFilm VisualSonics Vevo-LAZR system. Quantitative analysis on vessel densities exhibited gradual vessel growth successfully induced by catheter implantation. Our study demonstrates the ability of employing photoacoustic and micro-ultrasound imaging to track angiogenesis around the catheter site prior to islet transplantation.

Proceedings ArticleDOI
TL;DR: This work forms relative pressure images of microvessels by tracking vessel collapse as a function of externally applied pressure using photoacoustic imaging.
Abstract: Microcirculation may be characterized by the vascular pressure as it is influenced by pressure-driven perfusion. Crosssections of blood vessels can be visualized by photoacoustic imaging and compressing on vessels causes deformation. The photoacoustic signals of blood, when compressed to the point of vessel collapse, may or may not vanish depending on the buckling process it undergoes. We form relative pressure images of microvessels by tracking vessel collapse as a function of externally applied pressure using photoacoustic imaging.

01 Jan 2016
TL;DR: The array optical resolution photoacoustic micro-endoscopy (AOR-PAME) as mentioned in this paper system is designed to visualize the placement of the distal end of an endoscopy probe several centimeters into tissue, transmit scanning focused laser pulses into the fiber bundle, and acquire the generated photo- acoustic signals.
Abstract: Using a 0.8-mm-diameter image guide fiber bun- dle consisting of 30,000 single-mode fibers and an external linear array transducer, we demonstrate a dual-mode photo- acoustic system capable of ultrasound-guided micro- endoscope insertion and photoacoustic imaging. The array optical resolution photoacoustic microendoscopy (AOR- PAME) system is designed to visualize the placement of the distal end of an endoscopy probe several centimeters into tissue, transmit scanning focused laser pulses into tis- sues via the fiber bundle, and acquire the generated photo- acoustic signals. A ytterbium-doped fiber laser is tightly focused and is scanned across the proximal tip of the image guide fiber bundle using a two-dimensional galva- nometer scanning mirror system. The end of the fiber bundle is used in contact mode with the object. The capabilities of AOR-PAME are demonstrated by imaging carbon fiber net- works embedded in tissue-mimicking phantoms and the ears of a 60-g rat. The lateral resolution and signal-to- noise ratio are measured as 9 μm and 40 dB, respectively. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) (DOI: 10 .1117/1.JBO.18.9.090502)

Proceedings ArticleDOI
01 Sep 2016
TL;DR: In this article, a reflection-mode ultrasound scattering tomography system is introduced that is capable of in-plane isotropic half-wavelength diffraction-limited resolution by implementing an S-Sequence aperture encoding scheme, the Signal to Noise Ratio (SNR) is improved.
Abstract: A reflection-mode ultrasound scattering tomography system is introduced that is capable of in-plane isotropic half-wavelength diffraction-limited resolution. By implementing an S-Sequence aperture encoding scheme, the Signal to Noise Ratio (SNR) is improved. Resolution and SNR improvement were both measured experimentally with a ring array transducer.