About: Instituto Tecnológico de Morelia is a education organization based out in Morelia, Mexico. It is known for research contribution in the topics: Electric power system & AC power. The organization has 498 authors who have published 572 publications receiving 4600 citations.


Papers
More filters
Journal Article
TL;DR: In this article, a mathematical model was formulated, coded and validated to predict the evolution of the thermal and microstructural fields in steel probes subjected to the micro-structural degradation.
Abstract: A mathematical model was formulated, coded and validated to predict the evolution of the thermal and microstructural fields in steel probes subjected to the ...

3 citations

29 Jan 2011
TL;DR: In this article, the hydrodynamic behavior of the quenchant around a flat-end cylindrical probe was studied to explain the anomalies observed when quenching this type of probe in a fluid moving at relatively high velocities.
Abstract: The hydrodynamic behavior of the quenchant around a flat-end cylindrical probe was studied to explain the anomalies observed when quenching this type of probe in a fluid moving at relatively high velocities Both, physical and mathematical models were developed and compared with the observations made during the actual quenches which were conducted with water at 60°C flowing at 02, 04 and 06 m/s The computed streamlines compared favorably with the measured ones which validated the mathematical model The computed pressure field shows a significant gradient near the probe corner which produces backflow and an area of negative pressure which favors the occurrence of a localized thicker vapor blanket Thus, the use of the flat-end cylindrical probe for wetting kinematics studies is not recommended

3 citations

Proceedings ArticleDOI
01 Nov 2019
TL;DR: In this paper, the authors presented the analysis of electrical energy consumption of 76 high school buildings in the state of Michoacan, through linear regression analysis, energy audits and benchmarks.
Abstract: This paper presents the analysis of electrical energy consumption of 76 high school buildings in the state of Michoacan, through linear regression analysis, energy audits and benchmarks. The energy consumption is compared for each campus, obtaining a breakdown of consumption per student, m2 and turnover.Also, energy efficiency and savings opportunities that improve the energy performance of these high schools are analyzed.

3 citations

Journal ArticleDOI
TL;DR: In this article, a phase-domain frequency domain technique is proposed for the harmonic analysis of a three-phase AC/DC system based on the harmonic multi-port network concept, expressed in terms of an ABCD parameter matrix which links voltage and current harmonics of different orders on both sides of the converter.

3 citations


Network Information
Related Institutions (5)
Universidad Autónoma de San Luis Potosí
9.5K papers, 195.8K citations

80% related

CINVESTAV
19.9K papers, 463.3K citations

79% related

Instituto Politécnico Nacional
63.3K papers, 938.5K citations

78% related

University of Guadalajara
17.3K papers, 168K citations

77% related

Monterrey Institute of Technology and Higher Education
13.5K papers, 166.1K citations

76% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20223
202125
202040
201940
201847
201764