scispace - formally typeset
Search or ask a question

Showing papers in "arXiv: Medical Physics in 2008"


Posted Content
TL;DR: A review of the toxicity of nanoparticles is presented in this paper, with the goal of informing public health concerns related to nanoscience while raising awareness of nanomaterials toxicity among scientists and manufacturers handling them.
Abstract: This review is written with the goal of informing public health concerns related to nanoscience, while raising awareness of nanomaterials toxicity among scientists and manufacturers handling them. We show that humans have always been exposed to nanoparticles and dust from natural sources and human activities, the recent development of industry and combustion-based engine transportation profoundly increasing anthropogenic nanoparticulate pollution. The key to understanding the toxicity of nanoparticles is that their minute size, smaller than cells and cellular organelles, allows them to penetrate these basic biological structures, disrupting their normal function. Among diseases associated with nanoparticles are asthma, bronchitis, lung cancer, neurodegenerative diseases (such as Parkinson`s and Alzheimer`s diseases), Crohn`s disease, colon cancer. Nanoparticles that enter the circulatory system are related to occurrence of arteriosclerosis, and blood clots, arrhythmia, heart diseases, and ultimately cardiac death. We show that possible adverse effects of nanoparticles on human health depend on individual factors such as genetics and existing disease, as well as exposure, and nanoparticle chemistry, size, shape, and agglomeration state. The faster we will understand their causes and mechanisms, the more likely we are to find cures for diseases associated with nanoparticle exposure. We foresee a future with better-informed, and hopefully more cautious manipulation of engineered nanomaterials, as well as the development of laws and policies for safely managing all aspects of nanomaterial manufacturing, industrial and commercial use, and recycling.

2,652 citations


Journal ArticleDOI
TL;DR: In this paper, a mu-1 metamaterial lens for magnetic resonance imaging (MRI) is demonstrated, which manipulates the RF field detected by these surface coils, so that the coil sensitivity and spatial localization is substantially improved.
Abstract: In this work a mu=-1 metamaterial (MM) lens for magnetic resonance imaging (MRI) is demonstrated. MRI uses surface coils to detect the radiofrequency(RF) energy absorbed and emitted by the nuclear spins in the imaged object. The proposed MM lens manipulates the RF field detected by these surface coils, so that the coil sensitivity and spatial localization is substantially improved. Beyond this specific application, we feel that the reported results are the experimental confirmation of a new concept for the manipulation of RF field in MRI, which paves the way to many other interesting applications.

182 citations


Posted Content
TL;DR: In this article, an alternative and more realistic model established by the hyperbolic equation of heat transfer is presented. But the model is not suitable for the case of high energy fluxes.
Abstract: In modern surgery, a multitude of minimally intrusive operational techniques are used which are based on the punctual heating of target zones of human tissue via laser or radio-frequency currents. Traditionally, these processes are modeled by the bioheat equation introduced by Pennes, who considers Fourier's theory of heat conduction. We present an alternative and more realistic model established by the hyperbolic equation of heat transfer. To demonstrate some features and advantages of our proposed method, we apply the obtained results to different types of tissue heating with high energy fluxes, in particular radiofrequency heating and pulsed laser treatment of the cornea to correct refractive errors. Hopefully, the results of our approach help to refine surgical interventions in this novel field of medical treatment.

56 citations


Journal ArticleDOI
TL;DR: Results from the lateral fluid percussion model of TBI support the hypothesis that bullet impacts distant from the brain produce pressure waves that travel to the brain and can retain sufficient magnitude to induce brain injury.
Abstract: Identifying patients at risk of traumatic brain injury (TBI) is important because research suggests prophylactic treatments to reduce risk of long-term sequelae. Blast pressure waves can cause TBI without penetrating wounds or blunt force trauma. Similarly, bullet impacts distant from the brain can produce pressure waves sufficient to cause mild to moderate TBI. The fluid percussion model of TBI shows that pressure impulses of 15-30 psi cause mild to moderate TBI in laboratory animals. In pigs and dogs, bullet impacts to the thigh produce pressure waves in the brain of 18-45 psi and measurable injury to neurons and neuroglia. Analyses of research in goats and epidemiological data from shooting events involving humans show high correlations (r > 0.9) between rapid incapacitation and pressure wave magnitude in the thoracic cavity. A case study has documented epilepsy resulting from a pressure wave without the bullet directly hitting the brain. Taken together, these results support the hypothesis that bullet impacts distant from the brain produce pressure waves that travel to the brain and can retain sufficient magnitude to induce brain injury. The link to long-term sequelae could be investigated via epidemiological studies of patients who were gunshot in the chest to determine whether they experience elevated rates of epilepsy and other neurological sequelae.

40 citations


Journal ArticleDOI
TL;DR: In this article, the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields, was measured for different tissues at this field, were found to be close (within 5%) to the corresponding values of the transverse relaxation time at the same field.
Abstract: SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 microtesla field using a seven-channel SQUID system designed for microtesla MRI and MEG. Values of T1, measured for different tissues at this field, are found to be close (within 5%) to the corresponding values of the transverse relaxation time T2 at the same field. Implications of this result for imaging contrast in microtesla MRI are discussed.

32 citations


Journal ArticleDOI
TL;DR: A simple linear formula was derived that enabled the analytical formulation for ions stopping in water, which was designed to be equivalent with the extended Highland model and agreed with measurements within 2% or 0.02 cm in RMS displacement.
Abstract: Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particles in water, empirically found in measurements and detailed calculations. This fact was translated into a simple linear formula, from which the scattering power that is only inversely proportional to residual range was derived. The simplicity enabled analytical formulation for ions stopping in water, which was designed to be equivalent with the extended Highland model and agreed with measurements within 2% or 0.02 cm in RMS displacement. The simplicity will also improve the efficiency of numerical path integrals in the presence of heterogeneity.

31 citations


Posted Content
TL;DR: Methods, techniques and approaches successfully demonstrated for measuring or monitoring blood glucose, including invasive, minimally invasive and noninvasive techniques available in literature are summarised.
Abstract: Diabetes mellitus is a complex group of syndromes that have in common a disturbance in the body's use of glucose, resulting in an elevated blood sugar. Once detected, sugar diabetes can be controlled by an appropriate regimen that should include diet therapy, a weight reduction program for those persons who are overweight, a program of exercise and insulin injections or oral drugs to lower blood glucose. Blood glucose monitoring by the patient and the physician is an important aspect in the control of the devastating complications (heart disease, blindness, kidney failure or amputations) due to the disease. Intensive therapy and frequent glucose testing has numerous benefits. With ever improving advances in diagnostic technology, the race for the next generation of bloodless, painless, accurate glucose instruments has begun. In this paper, we reviewed various methods, techniques and approaches successfully demonstrated for measuring or monitoring blood glucose. Invasive, minimally invasive and noninvasive techniques available in literature are summarised.

31 citations


Proceedings ArticleDOI
TL;DR: Laser accelerated radiotherapy has a unique niche in a current world of high energy accelerator using synchrotron or cyclotron, where an ultra-compact accelerator system for cancer beam therapy can become affordable to a broad range of patients.
Abstract: Laser acceleration promises innovation in particle beam therapy of cancer where an ultra-compact accelerator system for cancer beam therapy can become affordable to a broad range of patients. This is not feasible without the introduction of a technology that is radically different from the conventional accelerator-based approach. The laser acceleration method provides many enhanced capabilities for the radiation oncologist. It reduces the overall system size and weight by more than one order of magnitude. The characteristics of the particle beams (protons) make them suitable for a class of therapy that might not be possible with the conventional accelerator, such as the ease for changing pulse intensity, the focus spread, the pinpointedness, and the dose delivery in general. A compact, uncluttered system allows a PET device to be located in the vicinity of the patient in concert with the compact gantry. The radiation oncologist may be able to irradiate a localized tumor by scanning with a pencil-like particle beam while ascertaining the actual dosage in the patient with an improved in-beam PET verification of auto-radioactivation induced by the beam therapy. This should yield an unprecedented flexibility in the feedback radiotherapy by the radiation oncologist. Laser accelerated radiotherapy has a unique niche in a current world of high energy accelerator using synchrotron or cyclotron.

27 citations


Journal ArticleDOI
TL;DR: In this paper, the authors proposed a beam-splitting method based on the self-similar nature of Gaussian distributions, where elementary Gaussian beams are split into narrower and deflecting daughter beams when their size has exceeded the lateral heterogeneity limit.
Abstract: The pencil-beam model is valid only when elementary Gaussian beams are small enough with respect to lateral heterogeneity of a medium, which is not always the case in heavy charged particle radiotherapy. This work addresses a solution for this problem by applying our discovery of self-similar nature of Gaussian distributions. In this method, Gaussian beams split into narrower and deflecting daughter beams when their size has exceeded the lateral heterogeneity limit. They will be automatically arranged with modulated areal density for accurate and efficient dose calculations. The effectiveness was assessed in an carbon-ion beam experiment in presence of steep range compensation, where the splitting calculation reproduced the detour effect of imperfect compensation amounting up to about 10% or as large as the lateral particle disequilibrium effect. The efficiency was analyzed in calculations for carbon-ion and proton radiations with a heterogeneous phantom model, where the splitting calculations took about a minute and were factor of 5 slower than the non-splitting ones. The beam-splitting method is reasonably accurate, efficient, and general so that it can be potentially used in various pencil-beam algorithms.

25 citations


Posted Content
TL;DR: In this article, the authors analyzed the changes in acceleration produced by swimmers before and after fatiguing effort, and showed that the acceleration analysis of the swimmer with Fourier analysis permits a more precise understanding of which propulsive forces contribute to the swimmers' performance.
Abstract: The present study analyzes the changes in acceleration produced by swimmers before and after fatiguing effort. The subjects (n=15) performed a 25-meter crawl series at maximum speed without fatigue, and a second series with fatigue. The data were registered with a synchronized system that consisted in a position transducer (1 kHz) and a video photogrametry (50Hz). The acceleration (ms-2) was obtained by the derivative analysis of the variation of the position with time. The amplitude in the time domain was calculated with the root mean square (RMS); while the peak power (PP), the peak power frequency (PPF) and the spectrum area (SA) was calculated in the frequency domain with Fourier analysis. On one hand, the results of the temporal domain show that the RMS change percentage between series was 67.5% (p<0.001). On the other hand, PP, PPF, and SA show significant changes (p<0.001). PP and SA were reduced by 63.1% and 59.5%, respectively. Our results show that the acceleration analysis of the swimmer with Fourier analysis permits a more precise understanding of which propulsive forces contribute to the swimmer performance before and after fatigue appears.

20 citations


Posted Content
TL;DR: In this paper, an original experimental procedure to measure mechanical interactions between the tongue and teeth during speech production is described, using edentulous people as subjects, pressure transducers are inserted in their complete denture duplicate.
Abstract: This paper describes an original experimental procedure to measure mechanical interactions between tongue and teeth during speech production. Using edentulous people as subjects, pressure transducers are inserted in their complete denture duplicate. Physiology is respected during sound and pressure recording as with standard complete denture. Original calibration device is also described in order to know what kind of information can be extracted from the data. The measurements are realized in different experimental conditions in order to remove the auditory and the orosensory feedbacks. Then the first results of the pilot study are presented

Proceedings ArticleDOI
TL;DR: The FCFM technique appears promising for in vivo exploration of the bronchial and alveolar extracellular matrix.
Abstract: Fibered confocal fluorescence microscopy (FCFM) is a new technique that can be used during a bronchoscopy to analyze the nature of the human bronchial and alveolar mucosa fluorescence microstructure An endoscopic fibered confocal fluorescence microscopy system with spectroscopic analysis capability was developed allowing real-time, simultaneous images and emission spectra acquisition at 488 nm excitation using a flexible miniprobe that could be introduced into small airways This flexible 14 mm miniprobe can be introduced into the working channel of a flexible endoscope and gently advanced through the bronchial tree to the alveoli FCFM in conjunction with bronchoscopy is able to image the in vivo autofluorescence structure of the bronchial mucosae but also the alveolar respiratory network outside of the usual field of view Microscopic and spectral analysis showed that the signal mainly originates from the elastin component of the bronchial subepithelial layer In non smokers, the system images the elastin backbone of the aveoli In active smokers, a strong autofluorescence signal appears from alveolar macrophages The FCFM technique appears promising for in vivo exploration of the bronchial and alveolar extracellular matrix

Posted Content
TL;DR: Two mathematical models to predict the release kinetics of a water soluble drug from a polymer/excipient matrix tablet are developed and will provide tools for designing better controlled release devices.
Abstract: In this paper we develop two mathematical models to predict the release kinetics of a water soluble drug from a polymer/excipient matrix tablet. The first of our models consists of a random walk on a weighted graph, where the vertices of the graph represent particles of drug, excipient and polymer, respectively. The graph itself is the contact graph of a multidisperse random sphere packing. The second model describes the dissolution and the subsequent diffusion of the active drug out of a porous matrix using a system of partial differential equations. The predictions of both models show good qualitative agreement with experimental release curves. The models will provide tools for designing better controlled release devices.

Journal ArticleDOI
TL;DR: A compact, portable instrument for measuring carotenoids in skin tissue using two light-emitting diodes for dual-wavelength excitation and four photomultiplier tubes for multichannel detection using the f1.3 optical system.
Abstract: We report on the development of a compact commercial instrument for measuring carotenoids in skin tissue. The instrument uses two light emitting diodes (LEDs) for dual-wavelength excitation and four photomultiplier tubes for multichannel detection. Bandpass filters are used to select the excitation and detection wavelengths. The f/1.3 optical system has high optical throughput and single photon sensitivity, both of which are crucial in LED-based Raman measurements. We employ a signal processing technique that compensates for detector drift and error. The sensitivity and reproducibility of the LED Raman instrument compares favorably to laser-based Raman spectrometers. This compact, portable instrument is used for non-invasive measurement of carotenoid molecules in human skin with a repeatability better than 10%.

Posted Content
TL;DR: In this article, a 3D biomechanical finite element model of the face is presented, where muscle insertion points are specific entities differing from nodes of the finite element mesh, which makes possible to change either the mesh or the muscle implementation totally independently of each other.
Abstract: A 3D biomechanical finite element model of the face is presented. Muscles are represented by piece-wise uniaxial tension cable elements linking the insertion points. Such insertion points are specific entities differing from nodes of the finite element mesh, which makes possible to change either the mesh or the muscle implementation totally independently of each other. Lip/teeth and upper lip/lower lip contacts are also modeled. Simulations of smiling and of an Orbicularis Oris activation are presented and interpreted. The importance of a proper account of contacts and of an accurate anatomical description is shown

Posted Content
TL;DR: In this paper, the authors considered two types of corrections due to the presence of beam-limiting and beam-shaping devices in proton planning: block-thickness and block scattering effects.
Abstract: The present paper pertains to corrections which are due to the presence of beam-limiting and beam-shaping devices in proton planning. Two types of corrections are considered: those which are due to the nonzero thickness of such devices (geometrical effects) and those relating to the scattering of beam particles off their material. The application of these two types of corrections is greatly facilitated by decomposing the physical effects (i.e., the contribution to the fluence) of two-dimensional objects (i.e., of the apertures of the devices) into one-dimensional, easily-calculable contributions. To minimise the time requirements in the derivation of the scattering corrections, a two-step process is introduced. The first step occurs at beam-configuration phase and comprises the analysis of half-block fluence measurements and the extraction of the one parameter of the model which is used in the description of the beamline characteristics; subsequently, a number of Monte-Carlo runs lead to the determination of the parameters of a convenient parameterisation of the relevant fluence contributions. The second step involves (at planning time) the reconstruction of the parameters (which are used in the description of the scattering contributions) via simple interpolations, performed on the results obtained during the beam-configuration phase. It is shown that the inclusion of the scattering effects leads to substantial improvement in the reproduction of the experimental data. The contributions from the block-thickness and block-scattering effects have been presented separately in the case of a simple water phantom. In this example, the maximal contribution of the block-relating effects amounts to a few percent of the prescribed dose.

Posted Content
TL;DR: In this article, a system composed by a scintillator crystal readout via a Micro Pixel Photon Counter (MPPC) is presented. But the performance of the LSO and LFS crystals is not compared.
Abstract: The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu is a good candidate for this application. Its small size (down to 1 mm2) and the high photo-detection efficiency in the blue spectral region allow the direct readout of a highly segmented scintillator matrix improving the spatial resolution of the machine. Furthermore, this photo-detector is insensitive to static magnetic fields up to 5 T, which makes it a possible candidate for applications in a magnetic resonance environment, though tests in a fast changing gradient field need still to be performed. The aim of this study is the characterization of a system composed by a scintillator crystal readout via a MPPC. Crystals of 1x1x15 mm3 and 3x3x15 mm3 are directly coupled to a MPPC of the same size active area and the energy resolution at 511 keV is measured. The coincidence time resolution of two so assembled detector units is measured. A first comparison of the performances of LSO and LFS crystals is given.

Posted Content
TL;DR: Seven distinct chains of evidence are presented, which, taken together, provide compelling support for the theory that a ballistic pressure wave radiating outward from the penetrating projectile can contribute to wounding and incapacitating effects of handgun bullets.
Abstract: This paper presents a summary of seven distinct chains of evidence, which, taken together, provide compelling support for the theory that a ballistic pressure wave radiating outward from the penetrating projectile can contribute to wounding and incapacitating effects of handgun bullets. These chains of evidence include the fluid percussion model of traumatic brain injury, observations of remote ballistic pressure wave injury in animal models, observations of rapid incapacitation highly correlated with pressure magnitude in animal models, epidemiological data from human shootings showing that the probability of incapacitation increases with peak pressure magnitude, case studies in humans showing remote pressure wave damage in the brain and spinal cord, and observations of blast waves causing remote brain injury.

Posted Content
TL;DR: In this paper, a method is presented for testing bullets at reduced velocities by loading the bullet into a sabot and firing from a muzzle loading rifle with a suitably reduced powder charge.
Abstract: Reconstruction of shooting events occasionally requires testing of bullets at velocities significantly below the typical muzzle velocity of cartridge arms. Trajectory, drag, and terminal performance depend strongly on velocity, and realistic results require accurately reconstructing the velocity. A method is presented for testing bullets at reduced velocities by loading the bullet into a sabot and firing from a muzzle loading rifle with a suitably reduced powder charge. Powder charges can be safely reduced to any desirable level when shooting saboted bullets from a muzzleloader; in contrast, cartridge arms can only be safely operated within a narrow window of powder charges/muzzle velocities. This technique is applicable to a wide range of both pistol and rifle bullets at velocities from 700 ft/s to 2000 ft/s.

Journal ArticleDOI
TL;DR: Here an image restoration on the basis of pixel simultaneous detection probabilities (PSDP) is proposed, which can be precisely determined by means of correlations measurement, based on the solution of matrix equation.
Abstract: Here an image restoration on the basis of pixel simultaneous detection probabilities (PSDP) is proposed. These probabilities can be precisely determined by means of correlations measurement [NIMA 586 (2008) 314-326]. The proposed image restoration is based on the solution of matrix equation. Non-zero elements of Toeplitz block matrix with ones on the main diagonal, is determined using PSDP. The number of non zero descending diagonals depends on the detector construction and is not always smaller than 8. To solve the matrix equation, the Gaussian elimination algorithm is used. The proposed restoration algorithm is studied by means of the simulated images (with and without additive noise using PSDP for General Electric Senographe 2000D mammography device detector) and a small area (160x160 pixels) of real images acquired by the above mentioned device. The estimation errors of PSDP and the additive noise magnitude permits to restore images with the precision better than 3% for the above mentioned detector. The additive noise in the real image is present after restoration and almost has the same magnitude. In the restored small area (16x16 mm) of real images, the pixel responses are not correlated. The spatial resolution improvement is also analyzed by the image of an absorber edge.

Posted Content
TL;DR: The D ICOM tags that contain information required for MC modeling of conformal and IMRT plans are described, and the development of an in-house DICOM interface is reported, through a library (named Vega) of platform-independent, object-oriented C++ codes.
Abstract: Monte Carlo (MC) methods provide the most accurate to-date dose calculations in heterogeneous media and complex geometries, and this spawns increasing interest in incorporating MC calculations into treatment planning quality assurance process. This involves MC dose calculations for clinically produced treatment plans. To perform these calculations, a number of treatment plan parameters specifying radiation beam and patient geometries need to be transferred to MC codes, such as BEAMnrc and DOSXYZnrc. Extracting these parameters from DICOM files is not a trivial task, one that has previously been performed mostly using Matlab-based software. This paper describes the DICOM tags that contain information required for MC modeling of conformal and IMRT plans, and reports the development of an in-house DICOM interface, through a library (named Vega) of platform-independent, object-oriented C++ codes. The Vega library is small and succinct, offering just the fundamental functions for reading/modifying/writing DICOM files in a C++ program. The library, however, is flexible enough to extract all MC required data from DICOM files, and write MC produced dose distributions into DICOM files that can then be processed in a treatment planning system environment. The library can be made available upon request to the authors.

Journal ArticleDOI
TL;DR: In this paper, the authors used flicker-noise spectroscopy (FNS) to determine the dynamic characteristics of neuromagnetic responses by analyzing the magnetoencephalographic (MEG) signals recorded as the response of a group of control human subjects and a patient with photosensitive epilepsy (PSE) to equiluminant flickering stimuli of different color combinations.
Abstract: The flicker-noise spectroscopy (FNS) approach is used to determine the dynamic characteristics of neuromagnetic responses by analyzing the magnetoencephalographic (MEG) signals recorded as the response of a group of control human subjects and a patient with photosensitive epilepsy (PSE) to equiluminant flickering stimuli of different color combinations. Parameters characterizing the analyzed stochastic biomedical signals for different frequency bands are identified. It is shown that the classification of the parameters of analyzed MEG responses with respect to different frequency bands makes it possible to separate the contribution of the chaotic component from the overall complex dynamics of the signals. It is demonstrated that the chaotic component can be adequately described by the anomalous diffusion approximation in the case of control subjects. On the other hand, the chaotic component for the patient is characterized by a large number of high-frequency resonances. This implies that healthy organisms can suppress the perturbations brought about by the flickering stimuli and reorganize themselves. The organisms affected by photosensitive epilepsy no longer have this ability. This result also gives a way to simulate the separate stages of the brain cortex activity in vivo. The examples illustrating the use of the "FNS device" for identifying even the slightest individual differences in the activity of human brains using their responses to external standard stimuli show a unique possibility to develop the "individual medicine" of the future.

Posted Content
TL;DR: In this article, a 3D finite element model of the tongue is used that represents this articulator as a deformable structure in which the tongue muscles anatomy is realistically described, and predictions of the consequences of tongue surgery on speech production are presented.
Abstract: This paper presents predictions of the consequences of tongue surgery on speech production. For this purpose, a 3D finite element model of the tongue is used that represents this articulator as a deformable structure in which tongue muscles anatomy is realistically described. Two examples of tongue surgery, which are common in the treatment of cancers of the oral cavity, are modelled, namely a hemiglossectomy and a large resection of the mouth floor. In both cases, three kinds of possible reconstruction are simulated, assuming flaps with different stiffness. Predictions are computed for the cardinal vowels /i, a, u/ in the absence of any compensatory strategy, i.e. with the same motor commands as the one associated with the production of these vowels in non-pathological conditions. The estimated vocal tract area functions and the corresponding formants are compared to the ones obtained under normal conditions

Posted Content
TL;DR: This paper briefly reviews many studies that document remote wounding effects of ballistic pressure waves including experiments in pigs and dogs that find brain injury resulting from animal models shot in the thigh and case studies in humans that document both remote brain and spinal cord injuries ascribed to Ballistic pressure waves.
Abstract: In response to a published assertion to the contrary, this paper briefly reviews many studies that document remote wounding effects of ballistic pressure waves including experiments in pigs and dogs that find brain injury resulting from animal models shot in the thigh and case studies in humans that document both remote brain and spinal cord injuries ascribed to ballistic pressure waves.

Journal ArticleDOI
TL;DR: In this paper, a numerical model which predicts the flow-induced collapse within the pharyngeal airway is validated using in vitro measurements, and the prediction accuracy of the numerical model is of 4.2% concerning the deformation.
Abstract: In the presented study, a numerical model which predicts the flow-induced collapse within the pharyngeal airway is validated using in vitro measurements. Theoretical simplifications were considered to limit the computation time. Systematic comparisons between simulations and measurements were performed on an in vitro replica, which reflects asymmetries of the geometry and of the tissue properties at the base of the tongue and in pathological conditions (strong initial obstruction). First, partial obstruction is observed and predicted. Moreover, the prediction accuracy of the numerical model is of 4.2% concerning the deformation (mean quadratic error on the constriction area). It shows the ability of the assumptions and method to predict accurately and quickly a fluid-structure interaction.

Posted Content
TL;DR: In this paper, the authors presented the well known aspect of non linearity of internal human body structures and showed that this internal well known knowledge is astonishing extendible from the internal, through the Brownian basis of the muscular contraction, to the macroscopic external human movements, like the orthostatic equilibrium, gait, running training, judo contest and soccer, basketball, football or water polo games, by means of the ubiquitous continuous presence; Brownian Dynamics.
Abstract: In this paper, it is presented the well known aspect of non linearity of internal human body structures. Similarity on the basis of the Fractional Brownian Motion from the static ones, as the geometrical fractals like the Intestine and placenta linings, Airways in lungs, Arterial system in kidneys and so on. To the kinematics ones, as the temporal fractals like Heart beat sequences, Electroencephalograms, Respiratory tidal volumes, DNA sequences mapping and so on. But this internal well known knowledge is astonishing extendible from the internal, through the Brownian basis of the muscular contraction, to the macroscopic external human movements, like the orthostatic equilibrium, gait, running training, judo contest and soccer, basketball, football or water polo games, by means of the ubiquitous continuous presence; the Brownian Dynamics.

Posted Content
TL;DR: A 3D discrete model is presented to model the movements of the trunk during breathing and pathology such as hemidiaphragm paralysis can also be simulated.
Abstract: In this paper, a 3D discrete model is presented to model the movements of the trunk during breathing. In this model, objects are represented by physical particles on their contours. A simple notion of force generated by a linear actuator allows the model to create forces on each particle by way of a geometrical attractor. Tissue elasticity and contractility are modeled by local shape memory and muscular fibers attractors. A specific dynamic MRI study was used to build a simple trunk model comprised of by three compartments: lungs, diaphragm and abdomen. This model was registered on the real geometry. Simulation results were compared qualitatively as well as quantitatively to the experimental data, in terms of volume and geometry. A good correlation was obtained between the model and the real data. Thanks to this model, pathology such as hemidiaphragm paralysis can also be simulated.

Posted Content
TL;DR: An article (J Trauma 29:10-18, 1989) cites unpublished woundBallistics data to support the authors' view that distant injuries are a myth in wound ballistics, but the actual data actually contains a number of detailed examples of distant injuries.
Abstract: An article (J Trauma 29:10-18, 1989) cites unpublished wound ballistics data to support the authors' view that distant injuries are a myth in wound ballistics. The actual data, published in 1990, actually contains a number of detailed examples of distant injuries. (Bellamy RF, Zajtchuk R. The physics and biophysics of wound ballistics. In: Zajtchuk R, ed. Textbook of Military Medicine, Part I: Warfare, Weaponry, and the Casualty, Vol. 5, Conventional Warfare: Ballistic, Blast, and Burn Injuries. Washington, DC: Office of the Surgeon General, Department of the Army, United States of America; 1990: 107-162.)

Posted Content
TL;DR: It is concluded that the supraespinal mechanism is responsible for the measured effect, by measuring the acceleration and the electromyography activity of the extensor digitorum at two different speeds.
Abstract: The influence of fatiguing stimuli applied to the quadriceps femoris on the tremor of the index finger on sixteen healthy subjects has been investigated, by measuring the acceleration and the electromyography activity of the extensor digitorum at two different speeds. No significant changes in the basal condition could be measured at 0.52 rad/s. However, at 1.05 rad/s the tremor amplitude (12.23%, p<0.05) and the electromyography activity (20.19%, p<0.05) increased in the time domain. In the frequential domain, the peak associated to the acceleration increased in 26.30% (p<0.05), while the electromiography activity experienced an increase of 81.34% (p<0.05). The largest change in frequency took place in the range 7-17 Hz. The discussion of the results leads to the conclusion that the supraespinal mechanism is responsible for the measured effect.

Posted Content
TL;DR: The physical understanding of a method of detecting mammalian cancer via vocalization during a normal echo-Doppler test is provided in this paper, where the backscattered ultrasound frequency in the case of a vocal humming resonating in the chest wall is computed: the overall effect is that the signal/noise ratio could be easily improved at no cost.
Abstract: The physical understanding of a method of detecting mammalian cancer via vocalization during a normal echo-Doppler test is provided The backscattered ultrasound frequency in the case of a vocal humming resonating in the chest wall is computed: the overall effect is that the signal/noise ratio could be easily improved at no cost Clinical results are to appear separately elsewhere