scispace - formally typeset
Journal ArticleDOI

A simple continuous method for calibration and measurement with ion-selective electrodes

G. Horvai, +2 more
- 01 Mar 1976 - 
- Vol. 82, Iss: 1, pp 45-54
Reads0
Chats0
TLDR
In this paper, a continuous method for calibration and measurement with ion-selective electrodes is developed, where the electrode is immersed into a solution diluted with respect to one of the components which influence the potential of the electrode.
About
This article is published in Analytica Chimica Acta.The article was published on 1976-03-01. It has received 41 citations till now. The article focuses on the topics: Calibration curve & Calibration.

read more

Citations
More filters
Journal ArticleDOI

Selectivity of potentiometric ion sensors.

TL;DR: A detailed recipe to determine correct potentiometric selectivity coefficients unaffected by such biases is presented.
Journal ArticleDOI

Picomolar detection limits with current-polarized Pb2+ ion-selective membranes.

TL;DR: The flux of lead ions across an ETH 5435 ionophore-based lead-selective membrane was gradually compensated by applying a few nanoamperes of galvanostatic current, and Nernstian response down to 3 x 10(-12) M was achieved.
Journal ArticleDOI

Direct evidence of ionic fluxes across ion-selective membranes: a scanning electrochemical microscopic and potentiometric study.

TL;DR: The amperometrically determined surface concentrations correlated well with the lower detection limits of the lead ion-selective electrodes.
Journal ArticleDOI

Improved detection limits and unbiased selectivity coefficients obtained by using ion-exchange resins in the inner reference solution of ion-selective polymeric membrane electrodes

TL;DR: Nernstian responses and, therefore, unbiased selectivity coefficients are obtained with the K+-ISE for the discriminated ions, Na+, Mg2+, and Ca2+.
References
More filters
Journal ArticleDOI

Development and publication of work with selective ion-sensitive electrodes

TL;DR: Recommendations are made concerning investigations involving the development and applications of electrodes and attention given to the manner of presenting data for publication.
Journal ArticleDOI

Computer-controlled monitoring and data reduction for multiple ion-selective electrodes in a flowing system

TL;DR: Analog and digital instrumentation have been developed for computer-controlled monitoring of multiple ion-selective electrodes in a flowing stream and rigorous least-squares analysis of standard addition data for up to five simultaneous electrode inputs.
Journal ArticleDOI

Experimental considerations on the ion selective electrode standard addition technique

TL;DR: In this article, a simple method for the determination of the response slope is proposed as follows: an indifferent electrolyte is added to a sample solution, standard solution and diluent in order to bring them to the same ionic strength.
Related Papers (5)