An adaptive PMU based fault detection/location technique for transmission lines. II. PMU implementation and performance evaluation

Reads0
Chats0
TLDR
In this article, a new timing device named "Global Synchronism Clock Generator, GSCG" including its hardware and software design is described in this paper, Experimental results show that the synchronized error of rising edge between the two GSCGs clock is well within 1 ps when the clock frequency is below 2.499 MHz.
Abstract
Part I of this paper set sets forth theory and algorithms for adaptive fault detection/location technique, which is based on phasor measurement unit (PMU). This paper is Part II of this paper set, A new timing device named "Global Synchronism Clock Generator, GSCG" including its hardware and software design is described in this paper, Experimental results show that the synchronized error of rising edge between the two GSCGs clock is well within 1 ps when the clock frequency is below 2.499 MHz. The measurement results between Chung-Jeng and Chang-Te 161 kV substations of Taiwan Power company by PMU equipped with GSCG is presented and the accuracy for estimating parameters of line is verified. The new developed DFT based method (termed as smart discrete Fourier transform, SDFT) and line parameter estimation algorithm are combined with PMU configuration to form the adaptive fault detector/locator system. Simulation results have shown that SDFT method can extract exact phasors in the presence of frequency deviation and harmonics, The parameter estimation algorithm can also trace exact parameters very well, The SDFT method and parameter estimation algorithm can achieve accuracies of up to 99.999% and 99.99%, respectively. The EMTP is used to simulate a 345 kV transmission line of Taipower System. Results have shown that the proposed technique yields correct results independent of fault types and is insensitive to the variation of source impedance, fault impedance and line loading. The accuracy of fault location estimation achieved can be up to 99.9% for many simulated cases, The proposed technique will be very suitable for implementation in an integrated digital protection and control system for transmission substations.

read more

Citations
More filters
Journal ArticleDOI

Development of adaptive protection scheme for distribution systems with high penetration of distributed generation

TL;DR: In this paper, the effect of high DG penetration on protective device coordination is explored and an adaptive protection scheme is proposed as a solution to the problems identified, which is implemented on a simulated actual distribution feeder.
Journal ArticleDOI

Dimensionality Reduction of Synchrophasor Data for Early Event Detection: Linearized Analysis

TL;DR: An early event detection algorithm based on the change of core subspaces of the PMU data at the occurrence of an event is proposed and theoretical justification for the algorithm is provided using linear dynamical system theory.
Journal ArticleDOI

Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art

TL;DR: This bibliography will aid academic researchers and practicing engineers in adopting appropriate topics and will stimulate utilities toward development and implementation of software packages.
Journal ArticleDOI

Fault Location in Power Distribution System With Penetration of Distributed Generation

TL;DR: In this article, the authors describe a general method to locate faults in a distributed generation (DG) system using synchronized voltage and current measurements at the interconnection of DG units and is able to adapt to changes in the topology of the system.
Journal ArticleDOI

Fault location on a transmission line using synchronized Voltage measurements

TL;DR: In this paper, a fault-location method for transmission lines using only synchronized voltage measurements at both ends of the line, eliminating the inherent error due to current transformers (CT) is presented.
References
More filters
Book

Computer Relaying for Power Systems

TL;DR: In this paper, the authors present a comprehensive, up-to-date account of computer relaying in power systems, based in part on the author's extensive experience in the field.
Journal ArticleDOI

State Estimlatjon with Phasor Measurements

TL;DR: In this paper, the authors present a state estimation algorithm for the IEEE 118 bus system, which involves an admittance-like matrix with the sparsity of the admittance matrix and converges in one step with the same amount of computation as one iteration of existing estimators.
Journal ArticleDOI

A new fault location technique for two- and three-terminal lines

TL;DR: In this article, a method for the computation of fault location in two and three-terminal high voltage lines is presented based on digital computation of the three-phase current and voltage 60/50 Hz phasors at the line terminals.
Journal ArticleDOI

Unsynchronized two-terminal fault location estimation

TL;DR: In this article, a technique for power system fault location estimation which uses data from both ends of a transmission line and which does not require the data to be synchronized is described, which can be easily applied for offline analysis.
Journal ArticleDOI

Accurate fault location technique for power transmission lines

TL;DR: In this article, the authors describe a very accurate fault location technique which uses post-fault voltage and current derived at both line ends, independent of fault resistance and the method does not require any knowledge of source impedance.
Related Papers (5)