scispace - formally typeset
Journal ArticleDOI

An Encounter With Lattice Boltzmann for Biomedical Applications: Interactive Simulation to Support Clinical and Design Decisions

TLDR
This paper investigates a new real-time tool for simulating structural and fluid scenarios - ANSYS Discovery Live - and evaluates its capability in the fluid domain through benchmark flows that all involve steady state flow at the inlet and zero pressure at the outlet.
Abstract
Medical device design for personalised medicine requires sophisticated tools for optimisation of biomechanical and biofluidic devices. This paper investigates a new real-time tool for simulating structural and fluid scenarios - ANSYS Discovery Live - and we evaluate its capability in the fluid domain through benchmark flows that all involve steady state flow at the inlet and zero pressure at the outlet. Three scenarios are reported: i. Laminar flow in a straight pipe, ii. vortex shedding from the Karman Vortex, and iii. nozzle flows as characterised by an FDA benchmark geometry. The solver uses a Lattice Boltzmann method requiring a high performance GPU (nVidiaGTX1080, 8GB RAM). Results in each case were compared with the literature and demonstrated credible solutions, all delivered in near real-time: i. The straight pipe delivered parabolic flow after an appropriate entrance length (plug flow inlet conditions), ii. the Karman Vortex demonstrated appropriate vortex shedding as a function of Reynolds number, characterised by Strouhal number in both the free field and within a pipe, and ii the FDA benchmark geometry generated results consistent with the literature in terms of variation of velocity along the centreline and in the radial direction, although deviation from experimental validation was evident in the sudden expansion section of the geometry. This behaviour is similar to previous reported results from Navier-Stokes solvers. A cardiovascular stenosis example is also considered, to provide a more direct biomedical context. The current software framework imposes constraints on inlet/outlet boundary conditions, and only supports limited control of solver discretization without providing full field vector flow data outputs. Nonetheless, numerous benefits result from the interactive interface and almost-real-time solution, providing a tool that may help to accelerate the arrival of improved patient-specific medical devices.

read more

References
More filters
Journal ArticleDOI

Vortex Dynamics in the Cylinder Wake

TL;DR: A review of wake vortex dynamics can be found in this article, with a focus on the three-dimensional aspects of nominally two-dimensional wake flows, as well as the discovery of several new phenomena in wakes.
Book

Flow-Induced Vibration

TL;DR: In this paper, the authors focus on applications for offshore platforms and piping; wind-induced vibration of buildings, bridges, and towers; and acoustic and mechanical vibration of heat exchangers, power lines, and process ducting.
Journal ArticleDOI

Virtual Fractional Flow Reserve From Coronary Angiography: Modeling the Significance of Coronary Lesions: Results From the VIRTU-1 (VIRTUal Fractional Flow Reserve From Coronary Angiography) Study

TL;DR: A computer model that accurately predicts myocardial fractional flow reserve (FFR) from angiographic images alone, in patients with coronary artery disease, was developed and was reliably predicted without the need for invasive measurements or inducing hyperemia.
Journal ArticleDOI

Assessment of CFD Performance in Simulations of an Idealized Medical Device: Results of FDA’s First Computational Interlaboratory Study

TL;DR: In this article, the authors conducted a computational interlaboratory study to determine the suitability and methodology for simulating fluid flow in an idealized medical device, which was a cylindrical nozzle with a conical collector and sudden expansion on either side of a 0.04 m long, 0.004 m diameter throat.
Journal ArticleDOI

Computed fractional flow reserve (FFTCT) derived from coronary CT angiography.

TL;DR: Computed FFRCT provides a combined anatomic and physiologic assessment of CAD in a single noninvasive test that can help select patients for invasive angiography and revascularization or best medical therapy.
Related Papers (5)