scispace - formally typeset
Journal ArticleDOI

Beat-to-beat measurement and analysis of the R-T interval in 24 h ECG Holter recordings

TLDR
The method described seems to provide a dynamic index of the sympatho-vagal balance at the ventricle that can be useful for a deeper understanding of ventricular repolarisation duration variability.
Abstract
This study assesses the feasibility of beat-to-beat measurement of the R-T interval in Holter ECG recordings. The low sampling rate of the Holter system was increased by a specific interpolating filter, and the precision and accuracy of two T-wave fiducial point (T-wave maximum: Tm, T-wave end: Te) detection algorithms were compared. The results of the validation tests show better performance of the Tm measurement procedure in the presence of high noise levels. The overall process for the beat-to-beat R-T interval measurement was then tested on ECG Holter recordings collected during free and controlled respiration. Finally, the R-Tm and the corresponding R-R intervals were measured on 24 h ECG recordings of healthy subjects and the spectral analysis was applied to the constructed series. Both R-R and R-Tm spectra show two main frequency components (low-frequency approximately 0.1 Hz, high-frequency approximately 0.25 Hz) changing in their power ratios continuously throughout the 24 h period. The method described seems to provide a dynamic index of the sympatho-vagal balance at the ventricle that can be useful for a deeper understanding of ventricular repolarisation duration variability.

read more

Citations
More filters
Journal ArticleDOI

A wavelet-based ECG delineator: evaluation on standard databases

TL;DR: A robust single-lead electrocardiogram (ECG) delineation system based on the wavelet transform (WT), outperforming the results of other well known algorithms, especially in determining the end of T wave.
Journal ArticleDOI

Autonomic nervous system and sudden cardiac death.

TL;DR: The two most important techniques used to study the autonomic nervous system--heart rate variability and baroreflex sensitivity--are reviewed, and the clinical and experimental data suggesting that these techniques are powerful predictors of future arrhythmic events are discussed in depth.
Journal ArticleDOI

Application of the phasor transform for automatic delineation of single-lead ECG fiducial points.

TL;DR: This work introduces a new single-lead ECG delineator based on phasor transform, which outperforms the results provided by other well-known delineation algorithms and, moreover, presents a notably lower computational cost.
Journal ArticleDOI

Effect of posture and isoproterenol on beat-to-beat heart rate and QT variability.

TL;DR: A change from the supine to the standing posture aswell as infusion of isoproterenol significantly increased the absolute as well as normalized QT variability, which appears to be due to an increase in sympathetic activity associated with these conditions.
References
More filters
Journal ArticleDOI

Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control

TL;DR: It is shown that sympathetic and parasympathetic nervous activity make frequency-specific contributions to the heart rate power spectrum, and that renin-angiotensin system activity strongly modulates the amplitude of the spectral peak located at 0.04 hertz.
Journal Article

An analysis of the time-relations of electrocardiograms

TL;DR: In this paper, a preliminary attempt was made to determine from blood pressure records the relative influence of the heart action and of vaso-canstriction, and it was suggested that it might be necessary to estimate the duration of ventricular systole for different heart rates.
Journal ArticleDOI

Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympatho-vagal interaction in man and conscious dog.

TL;DR: The spontaneous beat-to-beat oscillation in R-R interval during control recumbent position, 90° upright tilt, controlled respiration and acute and chronic β-adrenergic receptor blockade was analyzed, indicating that sympathetic nerves to the heart are instrumental in the genesis of low-frequency oscillations in R -R interval.
Journal Article

Assessment of autonomic function in human by heart rate spectral analysis

TL;DR: In this paper, the authors assessed spontaneous heart rate fluctuations by use of autonomic blocking agents and changes in posture, and found that low-frequency fluctuations (below 0.12 Hz) in the supine position are mediated entirely by the parasympathetic nervous system.
Journal ArticleDOI

Assessment of autonomic function in humans by heart rate spectral analysis

TL;DR: In this paper, the authors assessed spontaneous heart rate fluctuations by use of autonomic blocking agents and changes in posture, and found that low-frequency fluctuations (below 0.12 Hz) in the supine position are mediated entirely by the parasympathetic nervous system.
Related Papers (5)