scispace - formally typeset
Journal ArticleDOI

Improvements on Littmann's method of determining the size of retinal features by fundus photography.

Reads0
Chats0
TLDR
Three new methods of determining Littmann's factor q become available: simply reducing the axial length by a constant 1 · 82 mm; constructing a personalized schematic eye, given additional data; and ray tracing through this eye to extend calculations to peripheral retinal areas.
Abstract
Littmann's formula relating the size of a retinal feature to its measured image size on a telecentric fundus camera film is widely used. It requires only the corneal radius, ametropia, and Littmann's factor q obtained from nomograms or tables. These procedures are here computerized for practitioners' convenience. Basic optical principles are discussed, showing q to be a constant fraction of the theoretical ocular dimension k′, the distance from the eye's second principal point to the retina. If the eye's axial length is known, three new methods of determining q become available: (a) simply reducing the axial length by a constant 1 · 82 mm; (b) constructing a personalized schematic eye, given additional data; (c) ray tracing through this eye to extend calculations to peripheral retinal areas. Results of all these evaluations for 12 subjects of known ocular dimensions are presented for comparison. Method (a), the simplest, is arguably the most reliable. It shows good agreement with Littmann's supplementary procedure when the eye's axial length is known.

read more

Citations
More filters
Journal ArticleDOI

Adaptive optics: principles and applications in ophthalmology.

TL;DR: There are some limitations to using AO in a clinical setting including the cost of running an AO imaging service, the time needed to scan patients, the lack of normative databases and the very small size of area imaged.
Journal ArticleDOI

Cone Abnormalities in Fundus Albipunctatus Associated With RDH5 Mutations Assessed Using Adaptive Optics Scanning Laser Ophthalmoscopy

TL;DR: Macular cone density is lower and the regularity of the macular cone mosaic spatial arrangement is disrupted in eyes with fundus albipunctatus using adaptive optics scanning laser ophthalmoscopy (AO-SLO).
Journal ArticleDOI

Measurement of optic disc parameters on digital fundus photographs: algorithm development and evaluation.

TL;DR: A simple and rapid algorithm for optic disc measurements on digital fundus photographs, relying on the macula–disc centre distance as a reference when converting length expressed in pixels to metric distance is developed.
Journal ArticleDOI

Intraocular Pressure and Glaucomatous Optic Neuropathy in High Myopia.

TL;DR: GON was associated with elevated IOP in myopic Eyes with an axial length of ≤27.4 mm, while in more highly myopic eyes (axial length ≥27.5 mm), larger optic disc, longer axial elongation and older age-but not IOP mostly within its normal range-were factors associated with GON.
Journal ArticleDOI

The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length

TL;DR: Ocular magnification appears to be better accounted for when individual mean-K values are incorporated into Spectralis SD-OCT scan acquisition versus using the device’s default-K setting.
References
More filters
Journal ArticleDOI

Determination of the real size of an object on the fundus of the living eye

TL;DR: A method is described which allows the real diameter of an object on the fundus to be determined by means of a system of curves which are the result of trigonometrical calculations and which give an approximate value.
Book

Clinical Visual Optics

TL;DR: The eye's optical system visual acuity and contrast sensitivity spherical ametropia astigmatism subjective refraction accommodation and near vision ocular motility and binocularVision convergence anomalies of binocular vision - heterophoria and heterotropia stereopsis and the stereoscope.
Journal ArticleDOI

Determining the true size of an object on the fundus of the living eye

TL;DR: The result was represented by curves which enable factors used in calculating the true diameter to be determined, but instead of the curves a quadratic equation is used to produce the same factors.
Journal ArticleDOI

A method of determining the equivalent powers of the eye and its crystalline lens without resort to phakometry

TL;DR: If the positions of the principal points of the crystalline lens are conjectured, its equivalent power and that of the eye can be calculated as described from ocular dioptrics.
Related Papers (5)