scispace - formally typeset
Journal ArticleDOI

Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement

Reads0
Chats0
TLDR
A novel dry foam-based electrode, fabricated by electrically conductive polymer foam covered by a conductive fabric, performs better for long-term EEG measurement, and is practicable for daily life applications.
Abstract
A novel dry foam-based electrode for long-term EEG measurement was proposed in this study. In general, the conventional wet electrodes are most frequently used for EEG measurement. However, they require skin preparation and conduction gels to reduce the skin-electrode contact impedance. The aforementioned procedures when wet electrodes were used usually make trouble to users easily. In order to overcome the aforesaid issues, a novel dry foam electrode, fabricated by electrically conductive polymer foam covered by a conductive fabric, was proposed. By using conductive fabric, which provides partly polarizable electric characteristic, our dry foam electrode exhibits both polarization and conductivity, and can be used to measure biopotentials without skin preparation and conduction gel. In addition, the foam substrate of our dry electrode allows a high geometric conformity between the electrode and irregular scalp surface to maintain low skin-electrode interface impedance, even under motion. The experimental results presented that the dry foam electrode performs better for long-term EEG measurement, and is practicable for daily life applications.

read more

Citations
More filters
Proceedings ArticleDOI

A Novel Motion-Onset N200\P300 Brain-Computer Interface Paradigm * .

TL;DR: Experimental results showed that the BCI accuracy significantly increased and the false positive rate significantly decreased, indicating that the proposed motion-onset N200\P300 BCI paradigm has superior performance than a traditional P300-BCI paradigm.
Journal ArticleDOI

Reliable label efficient learning of eeg acquisition using electrodes

P Jegadeeshwari, +1 more
TL;DR: This paper reviews state-of-the-art bio-amplifier architectures and low-power analog circuits design techniques intended for wearable EEG acquisition, with a special focus on AE system interfaced with dry electrodes.
Proceedings ArticleDOI

Wide Frequency Impedance Meter Analysis

TL;DR: In this article , the capabilities of the Analog Devices AD5933 impedance network analyzer microcircuit, which performs high-speed single-frequency continuous impedance measurements, are investigated.
Journal ArticleDOI

Reduction in the Motion Artifacts in Noncontact ECG Measurements Using a Novel Designed Electrode Structure

TL;DR: In this article , a novel ECG electrode structure is designed to collect ECG data and reference data simultaneously, and the proposed design effectively suppresses motion artifacts and maintains the stability of the signal quality during the noncontact ECG acquisition.
References
More filters
Book

Medical instrumentation: Application and design

TL;DR: Basic Concepts of Medical Instrumentation (W. Olson).
Journal ArticleDOI

Scalp electrode impedance, infection risk, and EEG data quality

TL;DR: Evaluating the effect of electrode-scalp impedance on EEG data quality found no significant amplitude change in any EEG frequency bands as scalp-electrode impedance increased, suggesting that high-quality EEG can be recorded without skin abrasion.
Journal ArticleDOI

A direct comparison of wet, dry and insulating bioelectric recording electrodes.

TL;DR: A quantitative comparison of three types of bioelectrode (wet, dry and insulating) based on tests involving electrode impedance, static interference and motion artefact induced by various means indicates that in many situations the performance of dry andinsulating electrodes compares favourably with wet electrodes.
Journal ArticleDOI

EEG-based drowsiness estimation for safety driving using independent component analysis

TL;DR: In this paper, the authors developed a drowsiness-estimation system based on electroencephalogram (EEG) by combining independent component analysis (ICA), power-spectrum analysis, correlation evaluations, and linear regression model to estimate a driver's cognitive state when he/she drives a car in a virtual reality (VR)-based dynamic simulator.
Journal ArticleDOI

Flexible polymeric dry electrodes for the long-term monitoring of ECG

TL;DR: In this article, a polymeric dry electrode that changes its shape in a way that supports the electrode's contact with the skin and does not cause skin irritations or allergic reactions is presented.
Related Papers (5)