Optimal QRS detector.

Reads0
Chats0
TLDR
The problem of detecting the QRS complex in the presence of noise was analysed and an optimised threshold criterion based on FP/FN was developed.
Abstract
The problem of detecting the QRS complex in the presence of noise was analysed. Most QRS detectors contain a filter to improve the signal-to-noise ratio and compare the signal with a threshold. In an earlier paper we identified an optimal filter. Various techniques to generate threshold and detector designs were studied. Automatic gain-control circuits with a fixed threshold have a very slow response to different rhythms. Automatic threshold circuits based on simple peak-detection schemes have a fast response, but are very sensitive to sudden variations in QRS amplitudes and noise transients. None of the methods described to date present any optimisation criteria for detecting the signal (QRS complex) in the presence of noise. The probabilities of FPs (false positives) and FNs (false negatives) were investigated and an optimised threshold criterion based on FP/FN was developed. Presently, data are being collected to compare various techniques from their ROC (receiver operating characteristics).

read more

Citations
More filters
Journal ArticleDOI

A biomimetic skin phantom for characterizing wearable electrodes in the low-frequency regime.

TL;DR: In this paper , the authors proposed a skin phantom that mimics the electrical properties of the skin in the low-frequency range (1 Hz-1000 Hz), which has the potential to be used as a platform for controlled bench-top experiments for testing electrode functionality.
Book ChapterDOI

High resolution electrocardiography. Basic and clinical aspects

TL;DR: Two different techniques have been utilized to improve signal-to-noise ratio: 1) temporal averaging (usually referred as to as signal averaging) and low noise or high resolution ECG, which utilizes spatial averaging techniques, as well as other noise reducing measures, to record the His-Purkinje signal and late potentials on a beat- to-beat basis.
Journal ArticleDOI

Mining of an electrocardiogram

TL;DR: This paper focuses on the QRS complex detection in electrocardiogram but, the idea of further recognition of anomalies in QRS complexes based on the immunology approach is described, as well as a neural network ensemble proposed in order to detectQRS complexes.
Journal ArticleDOI

Dependence of Skin-Electrode Contact Impedance on Material and Skin Hydration

TL;DR: In this article , the performance of dry electrodes could be affected by electrode material and skin hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin.
Journal ArticleDOI

Wavelet-based compression of ECG signals

TL;DR: It is observed that even for higher Compression Ratio (CR) fidelity can be maintained and is verified by Cross-Correlation Coefficient (CCC) and the performance parameters can support the technique of data compression.
References
More filters
Book

Detection of signals in noise

TL;DR: In underwater sonar systems, external acoustic noise is generated by waves and wind on the water surface, by biological agents (fish, prawns, etc.), and by man-made sources such as engine noise.
BookDOI

Signal Detection Theory

TL;DR: This work presents theoretical principles of the generalized approach to signal detection theory and experimental study of generalized detectors type of signals in communications detction performances.
Book

Signal Detection Theory

TL;DR: The starting point for signal detection theory is that nearly all decision making takes place in the presence of some uncertainty, and the classic example of detecting brief, dim flashes of light in a dark room is begun.
Journal ArticleDOI

QRS wave detection.

TL;DR: A QRS complex detector based on optimum predetection with a matched filter is described, which shows that differentiation reduces Gaussian error by √6 and errors caused by variable QRS amplitudes are close to zero.