Oxidation, Damage Mechanisms, and Reasons for Revision of Sequentially Annealed Highly Crosslinked Polyethylene in Total Knee Arthroplasty

Reads0
Chats0
TLDR
The findings of this study document the revision reasons, surface damage modes, and oxidative behavior of sequentially annealed HXLPE for TKA and observed evidence of in vivo oxidation in both H XLPE and control tibial inserts.
Abstract
Background Sequentially annealed, highly crosslinked polyethylene (HXLPE) has been used clinically in total knee arthroplasty (TKA) for over a decade However, little is known about the revision reasons; its surface damage mechanisms; or its in vivo oxidative stability relative to conventional polyethylene We asked whether retrieved HLXPE tibial inserts exhibited: (1) similar revision reasons; (2) improved resistance to surface damage; and (3) improved oxidative stability, when compared with conventional gamma inert sterilized polyethylene inserts Methods A total of 456 revised tibial inserts were collected in a multicenter retrieval program between 2000 and 2016 The implantation time for the HXLPE components was 18 ± 18 years, and for the control inserts it was 34 ± 27 years Revision reasons were assessed based on medical records, radiographs, and examinations of the retrieved components Surface damage was assessed using a semi-quantitative scoring method Oxidation was measured using Fourier transform infrared spectroscopy Results The tibial inserts in both cohorts were revised most frequently for loosening, infection, and instability The most commonly observed surface damage modes were burnishing, pitting, and scratching Oxidation of the HXLPE inserts was, on average, low and similar to the control inserts at the bearing surface and the stabilizing post Conclusions We observed evidence of in vivo oxidation in both HXLPE and control tibial inserts We found no association between the levels of oxidation and the clinical performance of the HXLPE tibial components The findings of this study document the revision reasons, surface damage modes, and oxidative behavior of sequentially annealed HXLPE for TKA

read more

Citations
More filters
Journal ArticleDOI

Towards the understanding of lubrication mechanisms in total knee replacements – Part I: Experimental investigations

TL;DR: In this article, a knee simulator was used for direct optical observation of the contacts between a metal femoral and a transparent polymer component, and a novel lubrication model of the knee implant was proposed.
Journal ArticleDOI

Tackling the Concept of Symbiotic Implantable Medical Devices with Nanobiotechnologies.

TL;DR: This review takes an approach to implanted medical devices that considers whether the intention of the implanted device is to have any communication of energy or materials with the body, and extends the definition of a biocompatible system to one that requires stable exchange of materials between the implant and the body.
Journal ArticleDOI

Explant analysis of a Maestro™ wrist prosthesis and calculation of its lubrication regime

TL;DR: This study analysed an explanted metal-on-polymer Maestro wrist both in macro and nanoscales to estimate its biotribological performance and found the explant was found to operate under boundary lubrication.
Journal ArticleDOI

Insights into Oxidation of the Ultrahigh Molecular Weight Polyethylene Artificial Joint Related to Lipid Peroxidation

TL;DR: This work aimed to reveal the oxidation mechanism of UHMWPE joints with respect to squalene (a representative component of the synovial fluid), and provides evidence for comprehending the process ofSqualene-induced UH MWPE oxidation, and instructive to develop highly oxidative-resistant UhMWPE.
References
More filters
Journal ArticleDOI

Why are total knee arthroplasties failing today

TL;DR: Fifty percent of early revision total knee arthroplasties in this series were related to instability, malalignment or malposition, and failure of fixation, and half of the revisions in this group of patients were done less than 2 years after the index operation.
Journal ArticleDOI

The epidemiology of revision total knee arthroplasty in the United States.

TL;DR: Revision TKA procedures were most commonly performed in large, urban, nonteaching hospitals in Medicare patients ages 65 to 74, and the average length of hospital stay was 5.1 days, the average total charges were $49,360, however, average LOS, average charges, and procedure frequencies varied considerably by census region, hospital type, and Procedure performed.
Journal ArticleDOI

Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses

TL;DR: For the 48 total condylar-type prostheses, significant positive correlations were found for the surface damage correlated with the patient's weight and the time the prosthesis was implanted.
Book

UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices

TL;DR: The UHMWPE Handbook is the comprehensive reference for professionals, researchers, and clinicians working with biomaterials technologies for joint replacement, providing a more complete reference for industrial and academic materials specialists, and for surgeons and clinicians who require an understanding of the biomaterial's properties to work successfully on patient applications.
Journal ArticleDOI

The Chitranjan Ranawat Award: Long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties.

TL;DR: In this paper, the authors examined factors affecting survivorship, and reasons for reoperation and revision of a cemented modular condylar total knee arthroplasty (TKA).
Related Papers (5)