Journal ArticleDOI
Pre-oxidation of an extremely polluted industrial wastewater by the Fenton's reagent.
Nora San Sebastián Martı́nez,Josep Fı́guls Fernández,Xavier Font i Segura,Antoni Sánchez Ferrer +3 more
Reads0
Chats0
TLDR
In this article, the pre-oxidation of an extremely polluted pharmaceutical wastewater (chemical oxygen demand (COD) value of 362,000mg/l) using the Fenton's reagent has been systematically studied using an experimental design technique.About:
This article is published in Journal of Hazardous Materials.The article was published on 2003-08-01. It has received 192 citations till now. The article focuses on the topics: Fenton's reagent & Chemical oxygen demand.read more
Citations
More filters
Journal ArticleDOI
Electro-Fenton process and related electrochemical technologies based on Fenton's reaction chemistry
TL;DR: Electro-Fenton (EF) Process 6585 4.2.1.
Journal ArticleDOI
Removal of residual pharmaceuticals from aqueous systems by advanced oxidation processes.
TL;DR: The effectiveness of various AOPs for pharmaceutical removal from aqueous systems is assessed, including water and wastewater treatment, air pollution abatement and soil remediation.
Journal ArticleDOI
An overview of the application of Fenton oxidation to industrial wastewaters treatment
TL;DR: A review of the application of the Fenton process as an advanced oxidation method for the treatment of industrial wastewaters can be found in this article, where the efficiency and flexibility of this technology has been proven with a wide diversity of effluents from chemical and other related industries or activities, including pharmaceutical, pulp and paper, textile, food, cork processing and landfilling among others.
Journal ArticleDOI
The occurrence and fate of anti-inflammatory and analgesic pharmaceuticals in sewage and fresh water: treatability by conventional and non-conventional processes.
Asu Ziylan,Nilsun H. Ince +1 more
TL;DR: The present review is aimed to emphasize the occurrence of AI/AN wastes in sewage and fresh water bodies, their impacts on non-target organisms, and conversion or elimination by chemical, biochemical and physical treatment methods.
Journal ArticleDOI
Coagulation/flocculation process and sludge conditioning in beverage industrial wastewater treatment.
O.S. Amuda,I A Amoo +1 more
TL;DR: It can be concluded from this study that coagulation/flocculation may be a useful pre-treatment process for beverage industrial wastewater prior to biological treatment.
References
More filters
Journal ArticleDOI
Treatment and Reuse of Wastewater from the Textile Wet-Processing Industry : Review of Emerging Technologies
TL;DR: The main limitation of this approach is the treatment of the concentrate stream as discussed by the authors, which is a segment of the research dealing with the separate handling of speci-c sub-streams such as dyebath effluents to which membrane -ltration is sometimes applied.
Journal ArticleDOI
Advanced oxidation of a reactive dyebath effluent: comparison of O3, H2O2/UV-C and TiO2/UV-A processes.
TL;DR: In view of the electrical energy efficiency, ozonation and H2O2/UV-C oxidation at the selected treatment conditions appear to be promising candidates for full-scale dyehouse effluent decolorization.