scispace - formally typeset
Open AccessJournal ArticleDOI

Pulse oximetry: fundamentals and technology update

Reads0
Chats0
TLDR
The accuracy of SpO2 measurement is insufficient in several situations, such as critically ill patients receiving supplemental oxygen, and can be hazardous if it leads to elevated values of oxygen partial pressure in blood.
Abstract
Oxygen saturation in the arterial blood (SaO2) provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oximeter sensor, utilizing in vitro measurement of SaO2 in extracted arterial blood by means of co-oximetry. Due to the discrepancy between the measurement of SaO2 by pulse oximetry and the invasive technique, the former is denoted as SpO2. Manufacturers of pulse oximeters generally claim an accuracy of 2%, evaluated by the standard deviation (SD) of the differences between SpO2 and SaO2, measured simultaneously in healthy subjects. However, an SD of 2% reflects an expected error of 4% (two SDs) or more in 5% of the examinations, which is in accordance with an error of 3%-4%, reported in clinical studies. This level of accuracy is sufficient for the detection of a significant decline in respiratory function in patients, and pulse oximetry has been accepted as a reliable technique for that purpose. The accuracy of SpO2 measurement is insufficient in several situations, such as critically ill patients receiving supplemental oxygen, and can be hazardous if it leads to elevated values of oxygen partial pressure in blood. In particular, preterm newborns are vulnerable to retinopathy of prematurity induced by high oxygen concentration in the blood. The low accuracy of SpO2 measurement in critically ill patients and newborns can be attributed to the empirical calibration process, which is performed on healthy volunteers. Other limitations of pulse oximetry include the presence of dyshemoglobins, which has been addressed by multiwavelength pulse oximetry, as well as low perfusion and motion artifacts that are partially rectified by sophisticated algorithms and also by reflection pulse oximetry.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Wearable and flexible electronics for continuous molecular monitoring.

TL;DR: This article reviews and highlights recent advances in wearable and flexible sensors toward continuous and non-invasive molecular analysis in sweat, tears, saliva, interstitial fluid, blood, wound exudate as well as exhaled breath.
Journal ArticleDOI

Investigating sources of inaccuracy in wearable optical heart rate sensors

TL;DR: Different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity, and this has implications for researchers, clinicians, and consumers.
Journal Article

Pulmonary function testing

Marc Englert
- 01 Dec 1976 - 
Journal ArticleDOI

The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors

TL;DR: The technological advancements of mHealth bioaffinity sensors evolved from laboratory assays to portable POCT devices, and to wearable electronics, are synthesized and an outlook of the field is provided and key technological bottlenecks to overcome identified, in order to achieve a new sensing paradigm in wearable bioAffinity platforms.
Journal ArticleDOI

Flexible graphene photodetectors for wearable fitness monitoring.

TL;DR: This work demonstrates a new class of flexible and transparent wearables based on graphene sensitized with semiconducting quantum dots (GQD) that are able to monitor vital health signs noninvasively, including heart rate, arterial oxygen saturation (SpO2), and respiratory rate.
References
More filters
Book

Textbook of Medical Physiology

TL;DR: Textbook of medical physiology , Textbook ofmedical physiology , کتابخانه دیجیتال جندی شاپور اهواز
Journal ArticleDOI

Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.

TL;DR: The millimolar absorptivities of the four clinically relevant derivatives of fetal and adult human hemoglobin in the visible and near-infrared spectral range (450-1000 nm) were determined, and spectral absorption curves of similar shape were found.
Journal ArticleDOI

BTS guideline for emergency oxygen use in adult patients

TL;DR: The philosophy of the guideline and assessment of patients, monitoring and maintenance of target saturation, and oxygen administration are reviewed.
Journal ArticleDOI

Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications

TL;DR: This review reports on the progress of the NirS and NIRI instrumentation for brain and muscle clinical applications 30 years after the discovery of in vivo NIRS and summarizes the measurable parameters in relation to the different techniques.
Journal ArticleDOI

Pulmonary-Function Testing

TL;DR: Spirometry is the measurement of the movement of air into and out of the lungs during various breathing maneuvers, and is the most widely used such test.
Related Papers (5)