scispace - formally typeset
Journal ArticleDOI

Viability of Cardiac Parameters Measured Unobtrusively Using Capacitive Coupled Electrocardiography (cECG) to Estimate Driver Performance

TLDR
Validation of c ECG with conventional ECG will be very helpful in considering cECG as a good replacement of conventional ECGs to detect non-contact ubiquitous driver performance monitoring.
Abstract
A non-contact capacitive coupled electrocardiography (cECG) system to estimate driver’s fatigue is presented in this paper. Twenty male volunteers participated in this paper on a high fidelity driving simulator. To validate the cECG system, we have correlated it with conventional single lead ECG systems. Effect of perspiration on the cECG signal was also observed. Heart dynamics based on Poincare plot was estimated to observe fatigue. Magnitude square coherence analysis provided good coherence between conventional ECG and cECG signals whereas, signal quality of the cECG signals was observed better as time progressed probably due to effect of perspiration. Significant change (p < 0.05) in HRV dynamics and frequency measure of cECG signals was observed during course of driving. Correlation coefficients between non-linear indices of HRV (SD1, SD2, and SD1/SD2) and frequency measure indices of HRV (LF, HF, and LF/HF) were tested by the Spearman rank correlation test. Result from non-linear and frequency indices analysis of HRV showed significant change (p < 0.05) during course of simulated driving. Validation of cECG with conventional ECG will be very helpful in considering cECG as a good replacement of conventional ECG to detect non-contact ubiquitous driver performance monitoring.

read more

Citations
More filters

Controlled Inducement and Measurement of Drowsiness in a Driving Simulator

TL;DR: In this article, a multidimensional measurement of drowsiness in drivers was developed in order to find patterns in biomedical and biomechanical variables that allow to characterize the Drowsiness cycle.
Journal ArticleDOI

Linear and nonlinear analyses of normal and fatigue heart rate variability signals for miners in high-altitude and cold areas.

TL;DR: Deep insight is provided into the use of linear and nonlinear fatigue characteristics to effectively and reliably identify miner fatigue and provides a reference for clinical studies of acute mountain sickness in high-altitude, cold and hypoxic environments.
Journal ArticleDOI

Influence of Capacitive Coupling on High-Fidelity Non-Contact ECG Measurement

TL;DR: In this article, the authors developed a high-fidelity non-contact ECG system to evaluate the influence of capacitive coupling on ECG measurement and established a lower bound of the coupling capacitance for satisfactory signal quality.
Journal ArticleDOI

A Review on Measuring Affect with Practical Sensors to Monitor Driver Behavior

TL;DR: This review focuses on practical sensors that have the potential to provide reliable monitoring and meaningful feedback to vehicle operators—such as drivers, train operators, pilots, astronauts—as well as being feasible for implementation and integration with existing work infrastructure.
Journal ArticleDOI

Psychophysiological data-driven multi-feature information fusion and recognition of miner fatigue in high-altitude and cold areas.

TL;DR: Wang et al. as discussed by the authors performed field tests to measure fatigue psychophysiological parameters, such as electrocardiography (ECG), electromyography (EMG), pulse, blood pressure, reaction time and vital capacity (VC), in miners in high-altitude and cold areas and to perform multi-feature information fusion and fatigue identification.
References
More filters
Journal ArticleDOI

The assessment and analysis of handedness: The Edinburgh inventory

TL;DR: An inventory of 20 items with a set of instructions and response- and computational-conventions is proposed and the results obtained from a young adult population numbering some 1100 individuals are reported.
Journal ArticleDOI

Heart rate variability: a review

TL;DR: The various applications of HRV and different linear, frequency domain, wavelet domain, nonlinear techniques used for the analysis of the HRV are discussed.
Journal ArticleDOI

Power spectrum analysis of heart rate variability to assess the changes in sympathovagal balance during graded orthostatic tilt.

TL;DR: Spectral analysis of HRV, using nu or LF-to-HF ratio, appears to be capable of providing a noninvasive quantitative evaluation of graded changes in the state of the sympathovagal balance.
Related Papers (5)