scispace - formally typeset
Search or ask a question
JournalISSN: 0309-1902

Journal of Medical Engineering & Technology 

Informa
About: Journal of Medical Engineering & Technology is an academic journal published by Informa. The journal publishes majorly in the area(s): Medicine & Computer science. It has an ISSN identifier of 0309-1902. Over the lifetime, 1955 publications have been published receiving 27914 citations. The journal is also known as: Journal of medical engineering and technology.


Papers
More filters
Journal ArticleDOI
TL;DR: This review takes a broad look at what has been achieved in EIT and attempts to give the reader sufficient information to form an opinion as to the likely future for this interesting area of research.
Abstract: Electrical impedance tomography (EIT) has been the subject of quite intensive research for about 20 years but has yet to become established as a routine tool in healthcare. None the less the volume of published research work in this area is still rising. This review takes a broad look at what has been achieved and attempts to give the reader sufficient information to form an opinion as to the likely future for this interesting area of research.

546 citations

Journal ArticleDOI
TL;DR: The Microsoft Kinect has basic motion capture capabilities and with some minor adjustments will be an acceptable tool to measure stride timing, but sophisticated advances in software and hardware are necessary to improve Kinect™ sensitivity before it can be implemented for clinical use.
Abstract: Biomechanical analysis is a powerful tool in the evaluation of movement dysfunction in orthopaedic and neurologic populations. Three-dimensional (3D) motion capture systems are widely used, accurate systems, but are costly and not available in many clinical settings. The Microsoft Kinect™ has the potential to be used as an alternative low-cost motion analysis tool. The purpose of this study was to assess concurrent validity of the Kinect™ with Brekel Kinect software in comparison to Vicon Nexus during sagittal plane gait kinematics. Twenty healthy adults (nine male, 11 female) were tracked while walking and jogging at three velocities on a treadmill. Concurrent hip and knee peak flexion and extension and stride timing measurements were compared between Vicon and Kinect™. Although Kinect measurements were representative of normal gait, the Kinect™ generally under-estimated joint flexion and over-estimated extension. Kinect™ and Vicon hip angular displacement correlation was very low and error was large. Kinect™ knee measurements were somewhat better than hip, but were not consistent enough for clinical assessment. Correlation between Kinect™ and Vicon stride timing was high and error was fairly small. Variability in Kinect™ measurements was smallest at the slowest velocity. The Kinect™ has basic motion capture capabilities and with some minor adjustments will be an acceptable tool to measure stride timing, but sophisticated advances in software and hardware are necessary to improve Kinect™ sensitivity before it can be implemented for clinical use.

407 citations

Journal ArticleDOI
TL;DR: HRV can also be reliably estimated from the PPG based PP interval method and Bland-Altman analysis showed high degree of agreement between the two methods for all the parameters of HRV.
Abstract: Heart rate variability (HRV) is traditionally derived from RR interval time series of electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical activity. Thus, theoretically, PPG can be used for determining the interval between successive heartbeats and heart rate variability. However, the PPG wave lags behind the ECG signal by the time required for transmission of pulse wave. In this study, finger-tip PPG and standard lead II ECG were recorded for five minutes from 10 healthy subjects at rest. The results showed a high correlation (median = 0.97) between the ECG-derived RR intervals and PPG-derived peak-to-peak (PP) intervals. PP variability was accurate (0.1 ms) as compared to RR variability. The time domain, frequency domain and Poincare plot HRV parameters computed using RR interval method and PP interval method showed no significant differences (p < 0.05). The error analysis also showed insignificant differences between the HRV indices obtained by the two methods. Bland-Altman analysis showed high degree of agreement between the two methods for all the parameters of HRV. Thus, HRV can also be reliably estimated from the PPG based PP interval method.

302 citations

Journal ArticleDOI
TL;DR: The classification (Artificial Neural Network) based results have been presented for detecting different pre-defined arm motions in order to discriminate SEMG signals and indicates that a neural network classifier performs best with an average classification rate of 92.50%.
Abstract: This paper presents the detailed evaluation and classification of Surface Electromyogram (SEMG) signals at different upper arm muscles for different operations. After acquiring the data from selected locations, interpretation of signals was done for the estimation of parameters using simulated algorithm. First, different types of arm operations were analysed; then statistical techniques were implemented for investigating muscle force relationships in terms of amplitude estimation. The classification (Artificial Neural Network) based results have been presented for detecting different pre-defined arm motions in order to discriminate SEMG signals. The outcome of research indicates that a neural network classifier performs best with an average classification rate of 92.50%. Finally, the result also inferred the operations which were observed to be easy for arm recognition and the study is a step forward to develop powerful, flexible and efficient prosthetic designs.

300 citations

Journal ArticleDOI
TL;DR: IR imaging offers a useful and non-invasive approach to the diagnosis and treatment of many disorders, in particular in the areas of rheumatology, dermatology, orthopaedics and circulatory abnormalities.
Abstract: Since the early days of thermography in the 1950s, image processing techniques, sensitivity of thermal sensors and spatial resolution have progressed greatly, holding out fresh promise for infrared (IR) imaging techniques. Applications in civil, industrial and healthcare fields are thus reaching a high level of technical performance. The relationship between body temperature and disease was documented since 400 bc. In many diseases there are variations in blood flow, and these in turn affect the skin temperature. IR imaging offers a useful and non-invasive approach to the diagnosis and treatment (as therapeutic aids) of many disorders, in particular in the areas of rheumatology, dermatology, orthopaedics and circulatory abnormalities. This paper reviews many usages (and hence the limitations) of thermography in biomedical fields.

253 citations

Performance
Metrics
No. of papers from the Journal in previous years
YearPapers
20239
202272
202167
202052
201945
201864